ML18054A696

From kanterella
Jump to navigation Jump to search

Informs of Plan to Install PORV Variable Setpoint Control, New PORVs & Block Valves During 1990 Refueling Outage
ML18054A696
Person / Time
Site: Palisades 
Issue date: 04/17/1989
From: Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
TAC-72889, NUDOCS 8904250350
Download: ML18054A696 (1)


Text

consumers Power POWERINli MICHlliAN'S PROliRESS General Offices: 1945 West Parnall Road, Jackson,* Ml 49201 * (517) 788-0550 April 17, 1989 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

LOW TEMPERATURE OVERPRESSURE PROTECTION (LTOP) -

INSTALLATION OF VARIABLE SETPOINT (TAC NO. 72889)

Consumers Power Company letter dated November 10, 1988, informed the Staff that we planned to install the PORV variable setpoint control during the first outage of sufficient length after April 1, 1989.

This letter is to inform the Staff that we now plan to install the PORV variable setpoint control concurrent with the installation of new PORVs and block valves.

Concurrent installation of the variable setpoint and the new PORVs will facilitate operator training.

Although, as stated in our November 17, 1987 letter, we planned to install the new PORVs and block valves in the first planned outage of 45 days or more after September 1, 1989, no outages are planned after September 1, 1989 until the 1990 refueling outage.

Therefore, the installation of the new PORVs and block valves and the installation of the PORV variable setpoint control are now scheduled for the 1990 refueling outage.

Richard W Smedley Staff Licensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector - Palisades

~-- * :39c)425oa5c>--:3.?.<;>~ f7. ___.. ---- ~

F*r1R ADOCK 050U0~5~

p PDC OC0489-0119-NL02 A CMS ENERGY COMPANY