Line 16: | Line 16: | ||
| event date = 12/10/2003 18:00 EST | | event date = 12/10/2003 18:00 EST | ||
| last update date = 12/11/2003 | | last update date = 12/11/2003 | ||
| title = Reduction | | title = Reduction in Accident Mitigation Due to Improper Hpci Suction Transfer | ||
| event text = During the performance of planned Unit 2 High Pressure Coolant Injection (HPCI) Logic System Functional Surveillance testing an unexpected condition occurred. It was observed during the HPCI suction swap from the Condensate Storage Tank (CST) to the Torus, that the CST level lowered and the Torus level rose unexpectedly. At that time, the test was aborted and the system was restored to an available status but maintained Tech. Spec. inoperable pending additional evaluation. Following the evaluation, it was determined that the HPCI system Torus suction check valve permitted reverse flow. The HPCI system could not be restored to an operable status and requires additional troubleshooting and maintenance to return to an operable status." | | event text = During the performance of planned Unit 2 High Pressure Coolant Injection (HPCI) Logic System Functional Surveillance testing an unexpected condition occurred. It was observed during the HPCI suction swap from the Condensate Storage Tank (CST) to the Torus, that the CST level lowered and the Torus level rose unexpectedly. At that time, the test was aborted and the system was restored to an available status but maintained Tech. Spec. inoperable pending additional evaluation. Following the evaluation, it was determined that the HPCI system Torus suction check valve permitted reverse flow. The HPCI system could not be restored to an operable status and requires additional troubleshooting and maintenance to return to an operable status." | ||
The licensee notified the NRC Resident Inspector. | The licensee notified the NRC Resident Inspector. |
Latest revision as of 22:24, 1 March 2018
Where | |
---|---|
Peach Bottom ![]() Pennsylvania (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
Time - Person (Reporting Time:+0.82 h0.0342 days <br />0.00488 weeks <br />0.00112 months <br />) | |
Opened: | Alan Raush 23:49 Dec 10, 2003 |
NRC Officer: | Jeff Rotton |
Last Updated: | Dec 11, 2003 |