ENS 44587: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 10/21/2008 19:44 EDT
| event date = 10/21/2008 19:44 EDT
| last update date = 10/21/2008
| last update date = 10/21/2008
| title = Failure Of 250V Dc Hpci Injection Valve Undervoltage Relay  
| title = Failure of 250V Dc Hpci Injection Valve Undervoltage Relay  
| event text = A 250 Volt DC undervoltage relay for HPCI injection valve MO-2301-8 failed. The reason for the failure is still under investigation. The injection valve is a normally closed valve that opens on an initiation signal. The failure of the under voltage relay would prevent the HPCI injection valve (MO-2301-8) from opening and would prevent HPCI from performing its safety function. Pilgrim Station has entered a 14 day LCO due to Technical Specification 3.5.C.2.
| event text = A 250 Volt DC undervoltage relay for HPCI injection valve MO-2301-8 failed. The reason for the failure is still under investigation. The injection valve is a normally closed valve that opens on an initiation signal. The failure of the under voltage relay would prevent the HPCI injection valve (MO-2301-8) from opening and would prevent HPCI from performing its safety function. Pilgrim Station has entered a 14 day LCO due to Technical Specification 3.5.C.2.
The NRC Resident Inspector has been notified.
The NRC Resident Inspector has been notified.

Latest revision as of 21:13, 1 March 2018

ENS 44587 +/-
Where
Pilgrim
Massachusetts (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
LER: 05000293/LER-2008-004
Time - Person (Reporting Time:+0.02 h8.333333e-4 days <br />1.190476e-4 weeks <br />2.7396e-5 months <br />)
Opened: Bruce Chenard
23:45 Oct 21, 2008
NRC Officer: Donald Norwood
Last Updated: Oct 21, 2008
44587 - NRC Website
Loading map...