ENS 53108: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 12/08/2017 13:10 EST
| event date = 12/08/2017 13:10 EST
| last update date = 12/08/2017
| last update date = 12/08/2017
| title = High Pressure Coolant Injection Inoperable Due To A Leaking Check Valve  
| title = High Pressure Coolant Injection Inoperable Due to a Leaking Check Valve  
| event text = U/2 HPCI [Unit 2/High Pressure Coolant Injection] was declared inoperable due to leak by of the pump discharge check valve after pump shutdown from flow testing. This resulted in cycling of the minimum flow valve. The discharge valve was closed to prevent the continued cycling of the minimum flow valve. This condition was identified during normal surveillance testing.
| event text = U/2 HPCI [Unit 2/High Pressure Coolant Injection] was declared inoperable due to leak by of the pump discharge check valve after pump shutdown from flow testing. This resulted in cycling of the minimum flow valve. The discharge valve was closed to prevent the continued cycling of the minimum flow valve. This condition was identified during normal surveillance testing.
The licensee notified the NRC Resident Inspector.
The licensee notified the NRC Resident Inspector.

Latest revision as of 21:41, 1 March 2018

ENS 53108 +/-
Where
Limerick Constellation icon.png
Pennsylvania (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident
Time - Person (Reporting Time:+-0.75 h-0.0313 days <br />-0.00446 weeks <br />-0.00103 months <br />)
Opened: Rachel Heath
17:25 Dec 8, 2017
NRC Officer: Vince Klco
Last Updated: Dec 8, 2017
53108 - NRC Website
Loading map...