{{#Wiki_filter:Unrestricted Orano Orano NPS | {{#Wiki_filter:Unrestricted Orano Orano NPS SAFETY ANALYSIS CHAPTER 2.2 REPORT THERMAL ANALYSIS | ||
SAFETY ANALYSIS | |||
Formulaire : PM04-4-MO-6 rév. 03 | Prepared by 0 orano FCC4 / FCC3 Checked by | ||
Integration of explicit allowance for oxidation of the claddings by air | |||
Identification : DOS-19-021165-013-NPV Version : 1.0 Page 1 / 14 | |||
Tableofcontents Statusofrevision 2 Summary 3 | |||
: 1. Purpose 5 | |||
: 2. Inputdata 5 | |||
: 3. Determinationofmaximumtemperaturesreachedinnormalconditionsoftransport 5 | |||
: 4. Determinationofmaximumtemperaturesreachedbythecladdingsinaccidentalconditionsoftransport 6 | |||
: 5. Thermalmechanical analysisofcreepstrength 10 | |||
: 6. Analysisoftheimpact ofglycerine 11 | |||
: 7. AnalysisofthedeviationsintherepresentativenatureoftheEPRtop platewithrespecttotheconventionaltopplate 11 | |||
: 8. Analysisofthegeometricaldeviations intheEPRdoorswith respecttoconventionaldoors 12 | |||
: 9. Analysisoftheimpact ofthepresenceofthesmoothwalled dummy 12 10.Conclusion 13 11.References 13 ListofAppendices 14 | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 2 of 14 | |||
Status of revision | |||
English French Date Purpose and record of revisions Prepared by / Checked by version version Old reference : DOS-13-00081778-200 First issue Revision of Appendix 13 of Safety Analysis Report TFXDC 2158 revision H and Appendix 14 of Safety Analysis Report TFXDC 2159 revision G. | |||
00 00 04/2012 Integration of explicit allowance for oxidation of the claddings by air (Appendix 2.2-2). | |||
Integration of justification of non-allowance of oxidation of the claddings by steam. | Integration of justification of non-allowance of oxidation of the claddings by steam. | ||
Introduction of new thermal-mechanical calculations (Appendix 2.2-3). | Introduction of new thermal-mechanical calculations (Appendix 2.2-3). | ||
Addition of justifications relating to the potential presence of a maximum of | 01 01 12/2015 Addition of justifications relating to the potential presence of a maximum of 5g glycerine. | ||
Addition of the impact of pre-strain of claddings, caused by mechanical tests prior to thermal testing of their behaviour Addition of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock absorbers on completion of the thermal test. | Addition of the impact of pre-strain of claddings, caused by mechanical tests prior to thermal testing of their behaviour Addition of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock absorbers on completion of the thermal test. | ||
Update to paragraph 4: | Update to paragraph 4: | ||
Integration of new results for Appendix 2.2-3. | 02 02 10/2016 Integration of new results for Appendix 2.2-3. | ||
Update to Appendix 2.2-3. | |||
Shifting of the paragraph in Chapter 2.1-13, (dealing with the thermal impact) to this chapter. | Shifting of the paragraph in Chapter 2.1-13, (dealing with the thermal impact) to this chapter. | ||
Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate. | Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate. | ||
Analysis of the geometrical deviations in the EPR doors with respect to conventional doors. | Analysis of the geometrical deviations in the EPR doors with respect to conventional doors. | ||
Study of the addition of a chrome thickness up to 30 µm on the cladding | 1.0 03 11/2020 Study of the addition of a chrome thickness up to 30 µm on the cladding Update to Appendices 2.2-2 and 2.2-3 | ||
Non-proprietary version | |||
New reference: DOS-19-021165-013 | |||
See Deletion of the Appendix 2.2-2 1.0 1.0 first Rework of the Appendix 2.2-1 page Update of Appendix 2.2-3 calculation results Formal modifications | |||
BRAND NAMES | |||
AFA 3G, M5, Q12, MONOBLOC, TRAPPER, AGORA, HTP, HMP and ROBUST FUELGUARD are brands or registered brands of Fr amatome or its subsidiaries, in the USA or in other countries. | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 3 of 14 | |||
Summary The purpose of this Chapter is to describe th e thermal analysis of the FCC3 and FCC4 package models in normal and accidental conditions of transpor t in accordance with the regulations (reference | |||
<1>) applicable to industrial type packages loaded with fissile materials. | |||
This analysis includes: | This analysis includes: | ||
Determination of the maximum temperature | Determination of the maximum temperature r eached by the package under normal conditions of transport; Determination of the maximum temperatures reached by the fuel rod claddings under accident conditions of transport; The condition of the resin after fire; Thermal-mechanical analysis of the creep strength of the hottest cladding tubes; Analysis of the impact of 5g of glycerine in the fuel assemblies on the creep behaviour of the rods; Analysis of the impact of pre-strain of the claddings, caused by mechanical tests prior to thermal testing of their behaviour; Analysis of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock abs orbers on completion of the thermal test; Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate. | ||
Analysis of the geometrical deviations in | Analysis of the geometrical deviations in t he EPR doors with respect to conventional doors; Analysis of the impact of the presence of the smooth-walled dummy or assembly model; Analysis of the presence of a chrome coati ng thickness up to 30 µm on the fuel rod claddings. | ||
The thermal performance of the packaging was | |||
The maximum temperature reached by the FCC3 and FCC4 packages under normal conditions of transport is | The thermal performance of the packaging was evaluat ed by numerical calculation and tests for the neutron-absorbing resin then the strength of the enclosure (rod claddings) was studied. | ||
The maximum temperature reached by the FCC3 and FCC4 packages under normal conditions of transport is °C. | |||
The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C. | The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C. | ||
The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 or M5 Framatome cladding, due to creep, can be ruled out | |||
The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packagings shows that the impact upon the creep | The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 or M5 Framatome cladding, due to creep, can be ruled out wi th a minimum safety factor of 3.3. | ||
The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packagings shows that the impact upon the creep behav iour of the rods is negligible and does not affect the thermal-mechanical analyses detailed in the chapter. | |||
The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test. | The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test. | ||
Moreover, the increased heat caused by the | |||
Moreover, the increased heat caused by the potentia l combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assumptions used in the calculation of the maximum cladding temperatures, determined in Appendix 2.2-1. | |||
Adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL, XLR and GAIA assemblies, makes no difference to the chapters thermal analyses. | Adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL, XLR and GAIA assemblies, makes no difference to the chapters thermal analyses. | ||
The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses. | The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses. | ||
Formulaire : PM04-4-MO-6 rév. 03 | Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 4 of 14 | ||
Non-proprietary version | |||
The possible presence of a chrome coating on t he fuel rod claddings has no impact on the chapters thermal analyses. | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 5 of 14 | |||
: 1. Purpose | |||
The purpose of this Chapter is to describe th e thermal analysis of the FCC3 and FCC4 package models in normal and accidental conditions of transpor t in accordance with the regulations (reference | |||
<1>) applicable to industrial type packages loaded with fissile materials. | |||
This analysis includes: | This analysis includes: | ||
Determination of the maximum temperature | |||
The thermal performance of the packaging was | Determination of the maximum temperature r eached by the package under normal conditions of transport; | ||
: 2. | |||
Determination of the maximum temperatures r eached by the fuel rod claddings under accidental conditions of transport; | |||
The condition of the resin after fire; | |||
Thermal-mechanical analysis of the creep strength of the hottest cladding tubes; | |||
Analysis of the impact of 5g of glycerine in the fuel assemblies on the creep behaviour of the rods; Analysis of the impact of pre-strain of the claddings, caused by mechanical tests prior to thermal testing of their behaviour; Analysis of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock abs orbers on completion of the thermal test; Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate; Analysis of the geometrical deviations in t he EPR doors with respect to conventional doors; Analysis of the impact of the presence of the smooth-walled dummy or assembly model; Analysis of the presence of a chrome coati ng thickness up to 30 µm on the fuel rod claddings. | |||
The thermal performance of the packaging was evaluat ed by numerical calculation and tests for the neutron-absorbing resin then the strength of the enclosure (rod claddings) was studied. | |||
: 2. Input data | |||
A description of the package is given in Chapters 1.3 (contents) and 1.4 (packaging) of this Report. | |||
The thermal characteristics of the resin are given in Appendix 2.2-4. | The thermal characteristics of the resin are given in Appendix 2.2-4. | ||
Formulaire : PM04-4-MO-6 rév. 03 | Confinement of the material is provided by th e claddings and the only material of the packaging sensitive to high temperatures is the neutron absorbing resin. | ||
: 4. | |||
The condition of the package after drop tests repres entative of accidental conditions of transport is described in Chapter 2.1. | |||
: 3. Determination of maximum temperatures reached in normal conditions of transport | |||
The maximum temperatures reached by the component parts of the package under Normal Conditions of Transport are determined by the thermal analysis in Appendix 2.2-6, assuming an ambient temperature of 38°C and a solar flux applied for 12 hours out of every 24, as per regulation <1>. | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 6 of 14 | |||
: 4. Determination of maximum temperatures reached by the claddings in accidental conditions of transport | |||
4.1. Determination of maximum cladding temperatures | |||
The maximum temperatures reached by the claddi ngs in accidental conditions of transport are evaluated in Appendix 2.2-1 via numerical calculations. | |||
The studies realized in appendix 2.2-1 relate the case of fuel assemblies transportations and the case of rod transportations contained into rod boxes. | The studies realized in appendix 2.2-1 relate the case of fuel assemblies transportations and the case of rod transportations contained into rod boxes. | ||
On the basis of observations made following | |||
On the basis of observations made following t he mechanical tests (see Chapter 2.1 of this Report) the following assumptions were made in the calculations carried out: | |||
The outer shell was not modelled due to the fact that it perforated during the drop test onto a bar (conservative assumption); | The outer shell was not modelled due to the fact that it perforated during the drop test onto a bar (conservative assumption); | ||
The frame-door clearance was assumed to be | |||
The main general assumptions used for | The frame-door clearance was assumed to be mm at the flux entry point (top) and mm at the flux exit point (bottom) which bounds the post-drop observations. | ||
2D modelling of half of the internal equipment for reasons of symmetry, completed with a 3D modellings for the sensitivity analyses linked to the end assemblies singularities Fine modelling of the rods. | |||
Emissivity of the external | The main general assumptions used for m odelling purposes are summarized below: | ||
2D modelling of half of the internal equipment for reasons of symmetry, completed with a 3D modellings for the sensitivity analyses linked to the end assemblies singularities | |||
Fine modelling of the rods. | |||
Emissivity of the external surfac es of the claddings assumed to be with a sensitivity study for an emissivity value assumed to be. | |||
Analysis of Zircaloy-4 and M5 Framatome claddings. | Analysis of Zircaloy-4 and M5 Framatome claddings. | ||
Emissivity of the internal | |||
Emissivity of the internal wall s of the door and frame assumed to be. | |||
Modelling of non-degraded resin (conservative relative to modelling of air-calcined resin because intact resin has a higher conductivity). | Modelling of non-degraded resin (conservative relative to modelling of air-calcined resin because intact resin has a higher conductivity). | ||
Analysis of 16x16, 17x17 and 18x18 arrays in the FCC4 package (14x14 and 15x15 arrays in the FCC3 package were not modelled as these are covered by the arrays studied). | Analysis of 16x16, 17x17 and 18x18 arrays in the FCC4 package (14x14 and 15x15 arrays in the FCC3 package were not modelled as these are covered by the arrays studied). | ||
The physical properties of the materials vary with temperature, with the exception of the resin which the taken properties are | |||
The physical properties of the materials vary with temperature, with the exception of the resin which the taken properties are t hese corresponding to a temperature of °C. | |||
Conservatively, the container is in a horizontal position, inclined at ° angle according to the external shell revolutionnary axis. | Conservatively, the container is in a horizontal position, inclined at ° angle according to the external shell revolutionnary axis. | ||
Initial temperature | |||
During the fire phase, the coefficient of absorptivity of the external walls is assumed to be 0.8 and the convective exchange | Initial temperature °C. | ||
During the cooling phase, allowance for the outer shell by the addition of an equivalent thermal resistance and entering air at | |||
Details of the first calculation cases are | During the fire phase, the coefficient of absorptivity of the external walls is assumed to be 0.8 and the convective exchange coeffi cient is assumed to be 10 W/m²K. | ||
During the cooling phase, allowance for the outer shell by the addition of an equivalent thermal resistance and entering air at °C. | |||
Details of the first calculation cases are gi ven in Appendix 2.2-1 and are used to confirm the modelling hypothesis solidity. The studied ca ses and their results are summarized below: | |||
Low sentivity to the meshing and to the time stepping for the twodimensional models. | Low sentivity to the meshing and to the time stepping for the twodimensional models. | ||
Formulaire : PM04-4-MO-6 rév. 03 | Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 7 of 14 | ||
However, the numerical parameters used are more penalyzing than for the twodimensional cases, which ensure that the results of | |||
Sensitivity to laminar or turbulent flow | Low sentivity to the meshing and to the ti me stepping for the three-dimensional cases. | ||
Sensitivity to emissivity value of the internal side of the cavity (claddings, internal plates and guide tubes), allowing to conclude that an emissivity of | However, the numerical parameters used are more penalyzing than for the twodimensional cases, which ensure that the results of th ree-dimensional cases are conservatives. | ||
Sensitivity to laminar or turbulent flow syst ems, which allows to conclude about the laminar flow choice relevance. | |||
Sensitivity to emissivity value of the internal side of the cavity (claddings, internal plates and guide tubes), allowing to conclude that an emissivity of is conservative. | |||
The FCC packagings can carry different type of assemblies. An analysis of array sensitivity shows that the 17x17 array is more penalizing concerning the rising temperature of the cladding. | The FCC packagings can carry different type of assemblies. An analysis of array sensitivity shows that the 17x17 array is more penalizing concerning the rising temperature of the cladding. | ||
From the reference case, which is the analysis of the 17x17 array, modelled in 2 dimensions, the following sensitivity studies are carried out : | From the reference case, which is the analysis of the 17x17 array, modelled in 2 dimensions, the following sensitivity studies are carried out : | ||
Taken into account materials properties, considering the following cases : | Taken into account materials properties, considering the following cases : | ||
o Analysis of impact of M5 Framatome or Zircaloy-4 cladding material. | o Analysis of impact of M5 Framatome or Zircaloy-4 cladding material. | ||
o Analysis of impact of claddings pre-oxydation. | o Analysis of impact of claddings pre-oxydation. | ||
o Study of the addition of a chrome coating thickness up to 30 µm around the cladding. | o Study of the addition of a chrome coating thickness up to 30 µm around the cladding. | ||
Taken into account characteristics changes of the assemblies (rod diameter and pellet diameter). | Taken into account characteristics changes of the assemblies (rod diameter and pellet diameter). | ||
Taken into account three-dimensional effects : | Taken into account three-dimensional effects : | ||
o Assembly bottom zone. | o Assembly bottom zone. | ||
o Assembly top zone (considering pre-oxyded | |||
o Assembly top zone (considering pre-oxyded M5 Framatome or Zircaloy-4 claddings). | |||
Sentivity to the assembly deformation, due to drops, considering several possible configurations : | Sentivity to the assembly deformation, due to drops, considering several possible configurations : | ||
o Homogeneous expansion (the movement of rods is the same in all direction) o Heterogenous expansion (the movement | |||
o Homogeneous expansion (the movement of rods is the same in all direction) | |||
o Heterogenous expansion (the movement va ries according to the rod position) | |||
o Obstruction of the two gaps frame-door by rods. | |||
o Compacting mesured following the drop tests. | o Compacting mesured following the drop tests. | ||
A study of transports case with non-assembled rods in rod boxes is also realised and evaluate the impact : | A study of transports case with non-assembled rods in rod boxes is also realised and evaluate the impact : | ||
Of the rods number Of the rods box modelling The results of these investigations are presented below: | |||
The cladding material | Of the rods number | ||
Of the rods box modelling | |||
The results of these investigations are presented below: | |||
The cladding material M5 Framatome and Zircaloy-4 have a similar behavior. | |||
The changes in the assembly characteristics have little influence on the maximum temperatures reached. | |||
Allowance for array expansion leads to lo wer temperatures for the hottest claddings. | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 8 of 14 | |||
The changes in the assembly characteristics have little influence on the maximum temperatures reached. | The changes in the assembly characteristics have little influence on the maximum temperatures reached. | ||
Oxidation of the claddings by air has little in fluence on the maximum temperatures of the claddings. | |||
Oxidation of the claddings by air has little | |||
The addition of a thickness of chrome does not impact on the claddings temperatures. | The addition of a thickness of chrome does not impact on the claddings temperatures. | ||
Temperatures evaluation thank to a three- | |||
Temperatures evaluation thank to a three- | Temperatures evaluation thank to a three-di mensional model shows that the temperatures are not more penalizing on the bottom of the assembly. | ||
The making allowance for array expansion | |||
The making allowance of obturation of | Temperatures evaluation thank to a three-di mensional model shows that the temperatures are higher, localized manner, on the top of the assembly. | ||
The study of the array compacting shows | |||
The analysis of rods box transport case | The making allowance for array expansion lead s to lower temperatures for the hottest claddings. | ||
Following these evaluations, the temperature transients of the claddings for which the maximum temperature is over 600 °C are | |||
4.2. | The making allowance of obturation of gapsfr ame-door provides lower temperatures on all the claddings. | ||
The analyses show that a 100 % loss of hydrogen over a thickness of | |||
The study of the array compacting shows t hat, on average, the compacting provides lower temperatures on the claddings. | |||
The analysis of rods box transport case pr ovide lower temperatures on the claddings. | |||
Following these evaluations, the temperature transients of the claddings for which the maximum temperature is over 600 °C are extrac ted as input data for the thermal-mechanical creep strength study (see Appendix 2.2-3). Thus, the strength of the 3 hottest rods is analysed below (see § 5). | |||
4.2. Post-fire condition of resin | |||
The post-fire condition of the resin is descri bed in Appendix 2.2-4. This Appendix presents an analysis of FS69 resin samples exposed to an 800 °C flame for 30 minutes. | |||
The analyses show that a 100 % loss of hydrogen over a thickness of mm and an average loss of 10 % of the boron, over the full thickness are bounding values for the losses observed. | |||
These values are taken into account in the criticality studies described in Chapter 2.5. | These values are taken into account in the criticality studies described in Chapter 2.5. | ||
Formulaire : PM04-4-MO-6 rév. 03 | 4.3. Justification of non-inclusion of oxidation of the claddings by steam | ||
k | |||
The enthalpy of oxidation of zirconium by | The oxidation reaction which can take place between zirconium and steam is as follows: | ||
Oxidation of Zy-4 by air | Zr + 2 H20 => ZrO2 + 2 H2 | ||
4.4. | According to reference <2> the enthalpy associated with this reaction is: -585 kJ/mol. This reaction is therefore exothermic. The explicit m odel of the oxidation reaction of zirconium by air described in Appendix 2.2-1 shows a negligible effect on the post-fire cladding temperatures reached. The aim is therefore to compare the oxidative power of the oxidation reaction of zirconium by steam with the oxidative power of the oxidation reaction of zirconium by air. | ||
Cladding 1: T > °C for | H ZrO. | ||
Cladding 2: T > °C for | Oxidative power is expressed as follows: P 2..mZrO oxydation S2ZrO2 M ZrO2 | ||
Cladding 3: T > °C for | |||
In this formula the reaction enthalpy H and the surface reaction rate depend on the reaction. The molar mass of zirconium oxide M and the contact surface with the hot gases S are unchanged. According to reference <3>, the surface reaction rate is expressed | |||
. where t is time and k is a constant, which differs depending on as follows: m k. t the reaction. Thus, to compare the oxidative powers of the 2 reactions, a direct comparison of | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 9 of 14 | |||
the product H k is made for the different reactions. Reference document <3> gives the following expressions for the constant k: | |||
k 4,958 exp 89403/RT for the oxidation reaction of Zy-4 with air, | |||
k 0,1303 exp 54250/RT for the oxidation reaction of M5 Framatome with air, | |||
k 7,24 exp 87100/RT Leistikow-Schanz correlation applicable to the oxidation of zirconium alloy with steam, for temper atures ranging from 700 °C to 1600 °C. | |||
The enthalpy of oxidation of zirconium by ai r is given in Appendix 2.2-1 and has the value 1100 kJ/mol. The calculation of the product H k is given in the following table, taking into account a conservative temperature of 800 °C (1073 K): | |||
2 (kJ/mol) k (kg.m-2s-1/2) kHZrO H 2ZrO | |||
Oxidation of Zy-4 by air -1100 2.2x10 0.24 | |||
Oxidation of M5Framatome by air -1100 3x10-4 -0.33 | |||
Oxidation of a zirconium alloy by steam -585 4.2x10-4 -0.24 | |||
The results show that the oxidative power contributed by the oxidation reaction of zirconium by steam is comparable to that contributed by the oxidation reaction of zirconium by air. As determined in the previous section, making explicit allowance in the numerical calculations for oxidation of the cladding by air has little in fluence on maximum cladding temperatures and it is therefore justified not to take into account oxidation of the claddings by steam in the calculation of maximum cladding temperatures reached in accidental conditions of fire. | |||
4.4. Analysis of the impact of cladding deform ation resulting from the mechanical drop tests on their thermal-mechanical be haviour during the fire test | |||
Appendix 2.2-1 gives the three most conservati ve temperature transients for the zirconium alloy claddings during the regulatory fire test. These temperature transients can be simplified in the following manner: | |||
Cladding 1: T > °C for minutes, T > °C for minutes, T > °C for minutes, with a maximum temperature of °C. | |||
Cladding 2: T > °C for minutes, T > °C for minutes, with a maximum temperature of °C. | |||
Cladding 3: T > °C for minutes, T > °C for minutes and a maximum temperature of °C. | |||
These cladding types may, before the fire test, be locally distorted and strain-hardened when the assembly is dropped onto the bar. | These cladding types may, before the fire test, be locally distorted and strain-hardened when the assembly is dropped onto the bar. | ||
When these deformed claddings are subjected to the aforementioned temperature and timing conditions, one can expect a relaxation of the mechanical stresses created by the drop test, within these claddings. | When these deformed claddings are subjected to the aforementioned temperature and timing conditions, one can expect a relaxation of the mechanical stresses created by the drop test, within these claddings. | ||
Formulaire : PM04-4-MO-6 rév. 03 | Tensile tests carried out at ambient tem peratures, on strain-hardened claddings versus annealing time, at temperatures representative of the fire test ( °C, °C & °C) have been carried out, and an analysis of the data produced during these tests show that the strain- | ||
at °C - after | |||
We can therefore deduce that the temperature | Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 10 of 14 | ||
4.5. | |||
In addition, in the event the drop test onto a bar impacts on one of the two covers, and perforates it, the additional heat created by the | hardened zirconium alloy claddings are fully re-cr ystallised and that the internal stresses have been fully relaxed: | ||
Thus, the increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assumptions used in the calculation of the maximum cladding | |||
: 5. | at °C - after minutes held at this temperature, | ||
The analysis is made in the hottest zone of the rods for the cladding materials Zy-4 and | |||
at °C and °C - after the first minutes of annealing. | |||
We can therefore deduce that the temperature condi tions and the duration of the fire test will lead to a complete relaxation of the stresses ca used by the local deformations created prior to the test. Thus, the thermal-mechanical strength of these claddings is not brought into question by the deformations caused by the regulatory drop tests. | |||
4.5. Analysis of the impact of the maximum temperature of the fuel rods, in the case of the potential continuation of combustion of the wood in the shock absorbers on completion of the thermal test | |||
Any continuation of the combustion of the covers in FCC3 and FCC4 packagings, after the fire test, would have no impact on the results of the thermal study. In fact, the maximum temperature of the rods is determined on the basis of the circulation of hot air around the internal fittings of the FCC3 and FCC4 packagings. These maximum temperatures are determined conservatively, ignoring the shells and covers, in order to take into account perforation of the shell during the drop test onto a bar. Therefore there is no need to consider the additional heat created by the combustion of these covers. | |||
In addition, in the event the drop test onto a bar impacts on one of the two covers, and perforates it, the additional heat created by the co mbustion of the wood within this cover would below, given the volume of wood and the distance between the cover and the internal fittings (greater than mm). In addition, the flows of air around the internal fittings would be lower than those used by the Safety Analysis Report, due to the absence of the shell. | |||
Thus, the increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assumptions used in the calculation of the maximum cladding tem peratures, determined in Appendix 2.2-1. | |||
: 5. Thermal-mechanical analysis of creep strength | |||
Appendix 2.2-3 analyses the thermal-mechanical behaviour of a fuel rod in the conditions defined in Appendix 2.2-1 in order to rule out any ri sk of bursting of the claddings by creep. | |||
The analysis is made in the hottest zone of the rods for the cladding materials Zy-4 and M5 Framatome. | |||
The creep laws and instability criterion used in this Appendix are derived from the creep tests carried out on sections of M5Framatome and Zy-4 alloy cladding. | The creep laws and instability criterion used in this Appendix are derived from the creep tests carried out on sections of M5Framatome and Zy-4 alloy cladding. | ||
Formulaire : PM04-4-MO-6 rév. 03 | At each time step the circumferential stress is recalc ulated and compared to the instability criterion. It is also verified that the maximum circumferential strain remains acceptable. | ||
: 6. | |||
All the thermal and creep analyses, under regulatory | The minimum ratios (calculated circumferential stre ss/instability stress) are given below for the 3 hottest claddings: | ||
Cladding material M5Framatome: Cladding material Zy-4 : | |||
Cladding 1: 4.2, Cladding 1: 3.3, | |||
Cladding 2: 4.5, Cladding 2: 3.4, | |||
Cladding 3: 4.5 Cladding 3: 3.4 | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 11 of 14 | |||
Thus the risk of bursting of the claddings by creep is ruled out with a minimum safety factor of 4.2 for the M5Framatome cladding and 3.3 for the Zy-4 cladding. | |||
: 6. Analysis of the impact of glycerine | |||
Appendix 2.2-5 analyses, for FCC3 and FCC4 package m odels, the impact of the presence of 5g of glycerine in the fuel assemblies upon the studies covering the creep behaviour of the rods under regulatory fire conditions. It is proven that the heating of the claddings generates no significant distortions which might modify the thermal-mechanical behaviour of the rods during the fire test. | |||
All the thermal and creep analyses, under regulatory fi re conditions, in this report are conservatively carried out using the PWR 17x17 assemb ly, which covers all other types of fuel assembly, that is PWR 14x14 and PWR 15x15 assemblies. Therefore, the conc lusions of this analysis on the impact of glycerine on PWR 17x17 fuel assemblies are also applicable to the other types of assembly. | |||
Glycerine is a hydrogen-containing material, with an auto-ignition temperature less than the maximum temperature reached by the rods under the regulatory fire test conditions. | Glycerine is a hydrogen-containing material, with an auto-ignition temperature less than the maximum temperature reached by the rods under the regulatory fire test conditions. | ||
The evaluation of the temperatures of the claddings in the presence of 5g of glycerine is based upon two types of scenario: | The evaluation of the temperatures of the claddings in the presence of 5g of glycerine is based upon two types of scenario: | ||
Either, using analytic calculations following the layered combustion of glycerine during the regulatory fire test for ACT; Or, by numerical calculations, | Either, using analytic calculations following the layered combustion of glycerine during the regulatory fire test for ACT; Or, by numerical calculations, bas ed upon the results of flame tests. | ||
It has been shown that these scenarios have no impact on the resistance of fuel rod cladding to the phenomenon of creep. | It has been shown that these scenarios have no impact on the resistance of fuel rod cladding to the phenomenon of creep. | ||
This analysis is based upon the results of the creep studies, carried out in Appendix 2.2-1, which were carried out in the absence of glycerine. | This analysis is based upon the results of the creep studies, carried out in Appendix 2.2-1, which were carried out in the absence of glycerine. | ||
: 7. | : 7. Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate | ||
Chapter 1.4 details the securing of FCC3 and FCC4 a ssemblies, notably in terms of their top plate. In order to be able to transport the assembly with it s RCCA, a protrusion from the top plate is required to house and clamp its hub. Taking into account the materials used in the top plate (stainless steel and bronze), as well as this protrusion, their mec hanical strength has been shown, in Paragraph 3.5 | |||
- Chapter 2.1-13, to be maintained after the drops during ACT. Thus, the thermal inertia of the top plate remains unchanged. | |||
Moreover, given the absence of tearing on the protrusion, no opening providing an entry point for hot gases into the cavity can appear. Thus, the top plate does not cause any additional thermal impact on the behaviour of the internal equipment during fire test relative to the thermal analysis of the package given in this chapter and detailed in Appendices 2.2-1 and 2.2-3 to 2.2-5. | Moreover, given the absence of tearing on the protrusion, no opening providing an entry point for hot gases into the cavity can appear. Thus, the top plate does not cause any additional thermal impact on the behaviour of the internal equipment during fire test relative to the thermal analysis of the package given in this chapter and detailed in Appendices 2.2-1 and 2.2-3 to 2.2-5. | ||
Formulaire : PM04-4-MO-6 rév. 03 | Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 12 of 14 | ||
In accidental conditions of transport, the M8 screw in the claw system restraining the bottom nozzle of the assembly is sized so as to fail. Indeed, the | |||
Thus, the slide will not be damaged after the | The axial securing system for the as semblies, using their lower nozzle, is detailed in Paragraph 2.3, Chapter 1.4. The following draw ing illustrates this system. | ||
: 8. | |||
: 9. | In accidental conditions of transport, the M8 screw in the claw system restraining the bottom nozzle of the assembly is sized so as to fail. Indeed, the fr ee part of the M8 clamping screw is the most fragile part as it is therefore the element which will be subj ected to all of the tensile stresses due to the drops and which presents the smallest tensile stress area. It will be the first to fail following the drops. | ||
Non-proprietary version | |||
Thus, the slide will not be damaged after the failur e of the screw and will continue to perform its function of closing off the oblong hole in the top plat e irrespective of its position. The presence of the assembly bottom nozzle restraint system does not modi fy the leakage paths relative to the hot gas circulation paths in the cavity in accident conditions of fire, and the assembly restraint system via the bottom nozzle therefore has no impact on the thermal analysis of the package. | |||
: 8. Analysis of the geometrical deviations in th e EPR doors with respect to conventional doors | |||
As described in Paragraph 2.3.5.4 of Chapter 1.4, EPR fuel assembly grids are not positioned at the same elevations as the grids of XL/GAIA type assemblies or those of XLR type assemblies. Special doors (229 K 0670 in Appendix 1.4-1 of the FCC4 repor t) replace the conventional doors (229 K 0497 in Appendix 1.4-1 of the FCC4 report). The adaptation of the doors for the restraint system of the EPR fuel assembly grids has no impact on the thermal justification of the doors because the dimensions of the shoulders are negligible in relation to the ri bs and the increase of the stamped parts represents only a 30% increase in their surface area. | |||
: 9. Analysis of the impact of the presence of the smooth-walled dummy The material used in the smooth-walled dummy (sta inless steel) and its dimensions have no impact on the maximum temperature reached during the regulat ory fire test by the claddings of the EPR fuel assembly located within the second cavity of t he FCC4 packaging (moreover, the thermal model of the fire test in Appendix 2.2-1 only models a single cavity). | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 13 of 14 | |||
: 10. Conclusion | |||
The maximum temperature reached by the FCC3 and FCC4 packaged under normal conditions of transport was °C. | |||
The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C. | The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C. | ||
The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 and M5Framatome cladding, due to creep, can be ruled out | |||
The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 and M5Framatome cladding, due to creep, can be ruled out wi th a minimum safety factor of 3.3. | |||
There is therefore no dispersal of material on completion of the test representative of accidental conditions of transport. | There is therefore no dispersal of material on completion of the test representative of accidental conditions of transport. | ||
The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test. | The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test. | ||
The increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the | |||
The increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assu mptions used in the calculation of the maximum cladding temperatures, deter mined in Appendix 2.2-1. | |||
The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packages shows that the impact upon the creep behaviour of the rods is negligible and does not affect the thermal-mechanical analyses detailed in the chapter. | The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packages shows that the impact upon the creep behaviour of the rods is negligible and does not affect the thermal-mechanical analyses detailed in the chapter. | ||
The adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL/GAIA and XLR assemblies, makes no difference to the chapters thermal analyses. | The adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL/GAIA and XLR assemblies, makes no difference to the chapters thermal analyses. | ||
The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses. | The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses. | ||
: 11. References | : 11. References | ||
Formulaire : PM04-4-MO-6 rév. 03 | <1> Regulations for the Safe Transport of Radioactive Materials - at the revision indicated in Chapter 1.2. | ||
2.2-3 | |||
<2> <2>High Temperature Materials (HiTemp 2011 ) Conference organised by Netzsch, Boston, MA, USA, (20-22 Sept. 2011) | |||
<3> Zircaloy-4 and M5 high temperature oxidation and nitridin g in air, Duriez, C. and Dupont, T. | |||
and Schmet, B. and Enoch, F., Journal of Nuclear Materials, 2008 | |||
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 14 of 14 | |||
List of Appendices | |||
Appendix Title Number of pages | |||
2.2-1 Framatome document - D02-ARV-01-167-814 Revision A "Justification by CFD simulation of the thermal resistant of FCC package during fire test" 2 + 115 | |||
2.2-2 Deletion of the Appendix - | |||
2.2-3 Framatome document - "Fuel rod behaviour during IAEA thermal test in container " 37 | |||
2.2-4 TRANSNUCLEAIRE report 10373-B Rev. 3 "Summary note on the characterisation of FS 69 resin" 2 + 10 | |||
2.2-5 AREVA TN document - Analysis of the impact of glycerine on the thermal safety analyses 21 | |||
2.2-6 AREVA TN document - FCC package thermal behaviour in normal condition of transport 12 I >----------------------+---------I TOTAL 199 | |||
Non-proprietary version}} |
Latest revision as of 03:15, 16 November 2024
ML22277A768 | |
Person / Time | |
---|---|
Site: | 07103097 |
Issue date: | 08/03/2022 |
From: | Boyle R, Shaw D TN Americas LLC |
To: | Division of Fuel Management |
Garcia-Santos N | |
Shared Package | |
ML22277A716 | List:
|
References | |
A33010, L-2022-DOT-0008 | |
Download: ML22277A768 (14) | |
Text
Unrestricted Orano Orano NPS SAFETY ANALYSIS CHAPTER 2.2 REPORT THERMAL ANALYSIS
Prepared by 0 orano FCC4 / FCC3 Checked by
Identification : DOS-19-021165-013-NPV Version : 1.0 Page 1 / 14
Tableofcontents Statusofrevision 2 Summary 3
- 1. Purpose 5
- 2. Inputdata 5
- 3. Determinationofmaximumtemperaturesreachedinnormalconditionsoftransport 5
- 4. Determinationofmaximumtemperaturesreachedbythecladdingsinaccidentalconditionsoftransport 6
- 5. Thermalmechanical analysisofcreepstrength 10
- 6. Analysisoftheimpact ofglycerine 11
- 7. AnalysisofthedeviationsintherepresentativenatureoftheEPRtop platewithrespecttotheconventionaltopplate 11
- 8. Analysisofthegeometricaldeviations intheEPRdoorswith respecttoconventionaldoors 12
- 9. Analysisoftheimpact ofthepresenceofthesmoothwalled dummy 12 10.Conclusion 13 11.References 13 ListofAppendices 14
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 2 of 14
Status of revision
English French Date Purpose and record of revisions Prepared by / Checked by version version Old reference : DOS-13-00081778-200 First issue Revision of Appendix 13 of Safety Analysis Report TFXDC 2158 revision H and Appendix 14 of Safety Analysis Report TFXDC 2159 revision G.
00 00 04/2012 Integration of explicit allowance for oxidation of the claddings by air (Appendix 2.2-2).
Integration of justification of non-allowance of oxidation of the claddings by steam.
Introduction of new thermal-mechanical calculations (Appendix 2.2-3).
01 01 12/2015 Addition of justifications relating to the potential presence of a maximum of 5g glycerine.
Addition of the impact of pre-strain of claddings, caused by mechanical tests prior to thermal testing of their behaviour Addition of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock absorbers on completion of the thermal test.
Update to paragraph 4:
02 02 10/2016 Integration of new results for Appendix 2.2-3.
Update to Appendix 2.2-3.
Shifting of the paragraph in Chapter 2.1-13, (dealing with the thermal impact) to this chapter.
Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate.
Analysis of the geometrical deviations in the EPR doors with respect to conventional doors.
1.0 03 11/2020 Study of the addition of a chrome thickness up to 30 µm on the cladding Update to Appendices 2.2-2 and 2.2-3
New reference: DOS-19-021165-013
See Deletion of the Appendix 2.2-2 1.0 1.0 first Rework of the Appendix 2.2-1 page Update of Appendix 2.2-3 calculation results Formal modifications
BRAND NAMES
AFA 3G, M5, Q12, MONOBLOC, TRAPPER, AGORA, HTP, HMP and ROBUST FUELGUARD are brands or registered brands of Fr amatome or its subsidiaries, in the USA or in other countries.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 3 of 14
Summary The purpose of this Chapter is to describe th e thermal analysis of the FCC3 and FCC4 package models in normal and accidental conditions of transpor t in accordance with the regulations (reference
<1>) applicable to industrial type packages loaded with fissile materials.
This analysis includes:
Determination of the maximum temperature r eached by the package under normal conditions of transport; Determination of the maximum temperatures reached by the fuel rod claddings under accident conditions of transport; The condition of the resin after fire; Thermal-mechanical analysis of the creep strength of the hottest cladding tubes; Analysis of the impact of 5g of glycerine in the fuel assemblies on the creep behaviour of the rods; Analysis of the impact of pre-strain of the claddings, caused by mechanical tests prior to thermal testing of their behaviour; Analysis of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock abs orbers on completion of the thermal test; Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate.
Analysis of the geometrical deviations in t he EPR doors with respect to conventional doors; Analysis of the impact of the presence of the smooth-walled dummy or assembly model; Analysis of the presence of a chrome coati ng thickness up to 30 µm on the fuel rod claddings.
The thermal performance of the packaging was evaluat ed by numerical calculation and tests for the neutron-absorbing resin then the strength of the enclosure (rod claddings) was studied.
The maximum temperature reached by the FCC3 and FCC4 packages under normal conditions of transport is °C.
The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C.
The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 or M5 Framatome cladding, due to creep, can be ruled out wi th a minimum safety factor of 3.3.
The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packagings shows that the impact upon the creep behav iour of the rods is negligible and does not affect the thermal-mechanical analyses detailed in the chapter.
The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test.
Moreover, the increased heat caused by the potentia l combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assumptions used in the calculation of the maximum cladding temperatures, determined in Appendix 2.2-1.
Adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL, XLR and GAIA assemblies, makes no difference to the chapters thermal analyses.
The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 4 of 14
The possible presence of a chrome coating on t he fuel rod claddings has no impact on the chapters thermal analyses.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 5 of 14
- 1. Purpose
The purpose of this Chapter is to describe th e thermal analysis of the FCC3 and FCC4 package models in normal and accidental conditions of transpor t in accordance with the regulations (reference
<1>) applicable to industrial type packages loaded with fissile materials.
This analysis includes:
Determination of the maximum temperature r eached by the package under normal conditions of transport;
Determination of the maximum temperatures r eached by the fuel rod claddings under accidental conditions of transport;
The condition of the resin after fire;
Thermal-mechanical analysis of the creep strength of the hottest cladding tubes;
Analysis of the impact of 5g of glycerine in the fuel assemblies on the creep behaviour of the rods; Analysis of the impact of pre-strain of the claddings, caused by mechanical tests prior to thermal testing of their behaviour; Analysis of the impact on the maximum temperature of the fuel rods of potentially continuing with the combustion of the wood in the shock abs orbers on completion of the thermal test; Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate; Analysis of the geometrical deviations in t he EPR doors with respect to conventional doors; Analysis of the impact of the presence of the smooth-walled dummy or assembly model; Analysis of the presence of a chrome coati ng thickness up to 30 µm on the fuel rod claddings.
The thermal performance of the packaging was evaluat ed by numerical calculation and tests for the neutron-absorbing resin then the strength of the enclosure (rod claddings) was studied.
- 2. Input data
A description of the package is given in Chapters 1.3 (contents) and 1.4 (packaging) of this Report.
The thermal characteristics of the resin are given in Appendix 2.2-4.
Confinement of the material is provided by th e claddings and the only material of the packaging sensitive to high temperatures is the neutron absorbing resin.
The condition of the package after drop tests repres entative of accidental conditions of transport is described in Chapter 2.1.
- 3. Determination of maximum temperatures reached in normal conditions of transport
The maximum temperatures reached by the component parts of the package under Normal Conditions of Transport are determined by the thermal analysis in Appendix 2.2-6, assuming an ambient temperature of 38°C and a solar flux applied for 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> out of every 24, as per regulation <1>.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 6 of 14
- 4. Determination of maximum temperatures reached by the claddings in accidental conditions of transport
4.1. Determination of maximum cladding temperatures
The maximum temperatures reached by the claddi ngs in accidental conditions of transport are evaluated in Appendix 2.2-1 via numerical calculations.
The studies realized in appendix 2.2-1 relate the case of fuel assemblies transportations and the case of rod transportations contained into rod boxes.
On the basis of observations made following t he mechanical tests (see Chapter 2.1 of this Report) the following assumptions were made in the calculations carried out:
The outer shell was not modelled due to the fact that it perforated during the drop test onto a bar (conservative assumption);
The frame-door clearance was assumed to be mm at the flux entry point (top) and mm at the flux exit point (bottom) which bounds the post-drop observations.
The main general assumptions used for m odelling purposes are summarized below:
2D modelling of half of the internal equipment for reasons of symmetry, completed with a 3D modellings for the sensitivity analyses linked to the end assemblies singularities
Fine modelling of the rods.
Emissivity of the external surfac es of the claddings assumed to be with a sensitivity study for an emissivity value assumed to be.
Analysis of Zircaloy-4 and M5 Framatome claddings.
Emissivity of the internal wall s of the door and frame assumed to be.
Modelling of non-degraded resin (conservative relative to modelling of air-calcined resin because intact resin has a higher conductivity).
Analysis of 16x16, 17x17 and 18x18 arrays in the FCC4 package (14x14 and 15x15 arrays in the FCC3 package were not modelled as these are covered by the arrays studied).
The physical properties of the materials vary with temperature, with the exception of the resin which the taken properties are t hese corresponding to a temperature of °C.
Conservatively, the container is in a horizontal position, inclined at ° angle according to the external shell revolutionnary axis.
Initial temperature °C.
During the fire phase, the coefficient of absorptivity of the external walls is assumed to be 0.8 and the convective exchange coeffi cient is assumed to be 10 W/m²K.
During the cooling phase, allowance for the outer shell by the addition of an equivalent thermal resistance and entering air at °C.
Details of the first calculation cases are gi ven in Appendix 2.2-1 and are used to confirm the modelling hypothesis solidity. The studied ca ses and their results are summarized below:
Low sentivity to the meshing and to the time stepping for the twodimensional models.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 7 of 14
Low sentivity to the meshing and to the ti me stepping for the three-dimensional cases.
However, the numerical parameters used are more penalyzing than for the twodimensional cases, which ensure that the results of th ree-dimensional cases are conservatives.
Sensitivity to laminar or turbulent flow syst ems, which allows to conclude about the laminar flow choice relevance.
Sensitivity to emissivity value of the internal side of the cavity (claddings, internal plates and guide tubes), allowing to conclude that an emissivity of is conservative.
The FCC packagings can carry different type of assemblies. An analysis of array sensitivity shows that the 17x17 array is more penalizing concerning the rising temperature of the cladding.
From the reference case, which is the analysis of the 17x17 array, modelled in 2 dimensions, the following sensitivity studies are carried out :
Taken into account materials properties, considering the following cases :
o Analysis of impact of M5 Framatome or Zircaloy-4 cladding material.
o Analysis of impact of claddings pre-oxydation.
o Study of the addition of a chrome coating thickness up to 30 µm around the cladding.
Taken into account characteristics changes of the assemblies (rod diameter and pellet diameter).
Taken into account three-dimensional effects :
o Assembly bottom zone.
o Assembly top zone (considering pre-oxyded M5 Framatome or Zircaloy-4 claddings).
Sentivity to the assembly deformation, due to drops, considering several possible configurations :
o Homogeneous expansion (the movement of rods is the same in all direction)
o Heterogenous expansion (the movement va ries according to the rod position)
o Obstruction of the two gaps frame-door by rods.
o Compacting mesured following the drop tests.
A study of transports case with non-assembled rods in rod boxes is also realised and evaluate the impact :
Of the rods number
Of the rods box modelling
The results of these investigations are presented below:
The cladding material M5 Framatome and Zircaloy-4 have a similar behavior.
The changes in the assembly characteristics have little influence on the maximum temperatures reached.
Allowance for array expansion leads to lo wer temperatures for the hottest claddings.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 8 of 14
The changes in the assembly characteristics have little influence on the maximum temperatures reached.
Oxidation of the claddings by air has little in fluence on the maximum temperatures of the claddings.
The addition of a thickness of chrome does not impact on the claddings temperatures.
Temperatures evaluation thank to a three-di mensional model shows that the temperatures are not more penalizing on the bottom of the assembly.
Temperatures evaluation thank to a three-di mensional model shows that the temperatures are higher, localized manner, on the top of the assembly.
The making allowance for array expansion lead s to lower temperatures for the hottest claddings.
The making allowance of obturation of gapsfr ame-door provides lower temperatures on all the claddings.
The study of the array compacting shows t hat, on average, the compacting provides lower temperatures on the claddings.
The analysis of rods box transport case pr ovide lower temperatures on the claddings.
Following these evaluations, the temperature transients of the claddings for which the maximum temperature is over 600 °C are extrac ted as input data for the thermal-mechanical creep strength study (see Appendix 2.2-3). Thus, the strength of the 3 hottest rods is analysed below (see § 5).
4.2. Post-fire condition of resin
The post-fire condition of the resin is descri bed in Appendix 2.2-4. This Appendix presents an analysis of FS69 resin samples exposed to an 800 °C flame for 30 minutes.
The analyses show that a 100 % loss of hydrogen over a thickness of mm and an average loss of 10 % of the boron, over the full thickness are bounding values for the losses observed.
These values are taken into account in the criticality studies described in Chapter 2.5.
4.3. Justification of non-inclusion of oxidation of the claddings by steam
The oxidation reaction which can take place between zirconium and steam is as follows:
Zr + 2 H20 => ZrO2 + 2 H2
According to reference <2> the enthalpy associated with this reaction is: -585 kJ/mol. This reaction is therefore exothermic. The explicit m odel of the oxidation reaction of zirconium by air described in Appendix 2.2-1 shows a negligible effect on the post-fire cladding temperatures reached. The aim is therefore to compare the oxidative power of the oxidation reaction of zirconium by steam with the oxidative power of the oxidation reaction of zirconium by air.
H ZrO.
Oxidative power is expressed as follows: P 2..mZrO oxydation S2ZrO2 M ZrO2
In this formula the reaction enthalpy H and the surface reaction rate depend on the reaction. The molar mass of zirconium oxide M and the contact surface with the hot gases S are unchanged. According to reference <3>, the surface reaction rate is expressed
. where t is time and k is a constant, which differs depending on as follows: m k. t the reaction. Thus, to compare the oxidative powers of the 2 reactions, a direct comparison of
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 9 of 14
the product H k is made for the different reactions. Reference document <3> gives the following expressions for the constant k:
k 4,958 exp 89403/RT for the oxidation reaction of Zy-4 with air,
k 0,1303 exp 54250/RT for the oxidation reaction of M5 Framatome with air,
k 7,24 exp 87100/RT Leistikow-Schanz correlation applicable to the oxidation of zirconium alloy with steam, for temper atures ranging from 700 °C to 1600 °C.
The enthalpy of oxidation of zirconium by ai r is given in Appendix 2.2-1 and has the value 1100 kJ/mol. The calculation of the product H k is given in the following table, taking into account a conservative temperature of 800 °C (1073 K):
2 (kJ/mol) k (kg.m-2s-1/2) kHZrO H 2ZrO
Oxidation of Zy-4 by air -1100 2.2x10 0.24
Oxidation of M5Framatome by air -1100 3x10-4 -0.33
Oxidation of a zirconium alloy by steam -585 4.2x10-4 -0.24
The results show that the oxidative power contributed by the oxidation reaction of zirconium by steam is comparable to that contributed by the oxidation reaction of zirconium by air. As determined in the previous section, making explicit allowance in the numerical calculations for oxidation of the cladding by air has little in fluence on maximum cladding temperatures and it is therefore justified not to take into account oxidation of the claddings by steam in the calculation of maximum cladding temperatures reached in accidental conditions of fire.
4.4. Analysis of the impact of cladding deform ation resulting from the mechanical drop tests on their thermal-mechanical be haviour during the fire test
Appendix 2.2-1 gives the three most conservati ve temperature transients for the zirconium alloy claddings during the regulatory fire test. These temperature transients can be simplified in the following manner:
Cladding 1: T > °C for minutes, T > °C for minutes, T > °C for minutes, with a maximum temperature of °C.
Cladding 2: T > °C for minutes, T > °C for minutes, with a maximum temperature of °C.
Cladding 3: T > °C for minutes, T > °C for minutes and a maximum temperature of °C.
These cladding types may, before the fire test, be locally distorted and strain-hardened when the assembly is dropped onto the bar.
When these deformed claddings are subjected to the aforementioned temperature and timing conditions, one can expect a relaxation of the mechanical stresses created by the drop test, within these claddings.
Tensile tests carried out at ambient tem peratures, on strain-hardened claddings versus annealing time, at temperatures representative of the fire test ( °C, °C & °C) have been carried out, and an analysis of the data produced during these tests show that the strain-
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 10 of 14
hardened zirconium alloy claddings are fully re-cr ystallised and that the internal stresses have been fully relaxed:
at °C - after minutes held at this temperature,
at °C and °C - after the first minutes of annealing.
We can therefore deduce that the temperature condi tions and the duration of the fire test will lead to a complete relaxation of the stresses ca used by the local deformations created prior to the test. Thus, the thermal-mechanical strength of these claddings is not brought into question by the deformations caused by the regulatory drop tests.
4.5. Analysis of the impact of the maximum temperature of the fuel rods, in the case of the potential continuation of combustion of the wood in the shock absorbers on completion of the thermal test
Any continuation of the combustion of the covers in FCC3 and FCC4 packagings, after the fire test, would have no impact on the results of the thermal study. In fact, the maximum temperature of the rods is determined on the basis of the circulation of hot air around the internal fittings of the FCC3 and FCC4 packagings. These maximum temperatures are determined conservatively, ignoring the shells and covers, in order to take into account perforation of the shell during the drop test onto a bar. Therefore there is no need to consider the additional heat created by the combustion of these covers.
In addition, in the event the drop test onto a bar impacts on one of the two covers, and perforates it, the additional heat created by the co mbustion of the wood within this cover would below, given the volume of wood and the distance between the cover and the internal fittings (greater than mm). In addition, the flows of air around the internal fittings would be lower than those used by the Safety Analysis Report, due to the absence of the shell.
Thus, the increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assumptions used in the calculation of the maximum cladding tem peratures, determined in Appendix 2.2-1.
- 5. Thermal-mechanical analysis of creep strength
Appendix 2.2-3 analyses the thermal-mechanical behaviour of a fuel rod in the conditions defined in Appendix 2.2-1 in order to rule out any ri sk of bursting of the claddings by creep.
The analysis is made in the hottest zone of the rods for the cladding materials Zy-4 and M5 Framatome.
The creep laws and instability criterion used in this Appendix are derived from the creep tests carried out on sections of M5Framatome and Zy-4 alloy cladding.
At each time step the circumferential stress is recalc ulated and compared to the instability criterion. It is also verified that the maximum circumferential strain remains acceptable.
The minimum ratios (calculated circumferential stre ss/instability stress) are given below for the 3 hottest claddings:
Cladding material M5Framatome: Cladding material Zy-4 :
Cladding 1: 4.2, Cladding 1: 3.3,
Cladding 2: 4.5, Cladding 2: 3.4,
Cladding 3: 4.5 Cladding 3: 3.4
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 11 of 14
Thus the risk of bursting of the claddings by creep is ruled out with a minimum safety factor of 4.2 for the M5Framatome cladding and 3.3 for the Zy-4 cladding.
- 6. Analysis of the impact of glycerine
Appendix 2.2-5 analyses, for FCC3 and FCC4 package m odels, the impact of the presence of 5g of glycerine in the fuel assemblies upon the studies covering the creep behaviour of the rods under regulatory fire conditions. It is proven that the heating of the claddings generates no significant distortions which might modify the thermal-mechanical behaviour of the rods during the fire test.
All the thermal and creep analyses, under regulatory fi re conditions, in this report are conservatively carried out using the PWR 17x17 assemb ly, which covers all other types of fuel assembly, that is PWR 14x14 and PWR 15x15 assemblies. Therefore, the conc lusions of this analysis on the impact of glycerine on PWR 17x17 fuel assemblies are also applicable to the other types of assembly.
Glycerine is a hydrogen-containing material, with an auto-ignition temperature less than the maximum temperature reached by the rods under the regulatory fire test conditions.
The evaluation of the temperatures of the claddings in the presence of 5g of glycerine is based upon two types of scenario:
Either, using analytic calculations following the layered combustion of glycerine during the regulatory fire test for ACT; Or, by numerical calculations, bas ed upon the results of flame tests.
It has been shown that these scenarios have no impact on the resistance of fuel rod cladding to the phenomenon of creep.
This analysis is based upon the results of the creep studies, carried out in Appendix 2.2-1, which were carried out in the absence of glycerine.
- 7. Analysis of the deviations in the representative nature of the EPR top plate with respect to the conventional top plate
Chapter 1.4 details the securing of FCC3 and FCC4 a ssemblies, notably in terms of their top plate. In order to be able to transport the assembly with it s RCCA, a protrusion from the top plate is required to house and clamp its hub. Taking into account the materials used in the top plate (stainless steel and bronze), as well as this protrusion, their mec hanical strength has been shown, in Paragraph 3.5
- Chapter 2.1-13, to be maintained after the drops during ACT. Thus, the thermal inertia of the top plate remains unchanged.
Moreover, given the absence of tearing on the protrusion, no opening providing an entry point for hot gases into the cavity can appear. Thus, the top plate does not cause any additional thermal impact on the behaviour of the internal equipment during fire test relative to the thermal analysis of the package given in this chapter and detailed in Appendices 2.2-1 and 2.2-3 to 2.2-5.
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 12 of 14
The axial securing system for the as semblies, using their lower nozzle, is detailed in Paragraph 2.3, Chapter 1.4. The following draw ing illustrates this system.
In accidental conditions of transport, the M8 screw in the claw system restraining the bottom nozzle of the assembly is sized so as to fail. Indeed, the fr ee part of the M8 clamping screw is the most fragile part as it is therefore the element which will be subj ected to all of the tensile stresses due to the drops and which presents the smallest tensile stress area. It will be the first to fail following the drops.
Thus, the slide will not be damaged after the failur e of the screw and will continue to perform its function of closing off the oblong hole in the top plat e irrespective of its position. The presence of the assembly bottom nozzle restraint system does not modi fy the leakage paths relative to the hot gas circulation paths in the cavity in accident conditions of fire, and the assembly restraint system via the bottom nozzle therefore has no impact on the thermal analysis of the package.
- 8. Analysis of the geometrical deviations in th e EPR doors with respect to conventional doors
As described in Paragraph 2.3.5.4 of Chapter 1.4, EPR fuel assembly grids are not positioned at the same elevations as the grids of XL/GAIA type assemblies or those of XLR type assemblies. Special doors (229 K 0670 in Appendix 1.4-1 of the FCC4 repor t) replace the conventional doors (229 K 0497 in Appendix 1.4-1 of the FCC4 report). The adaptation of the doors for the restraint system of the EPR fuel assembly grids has no impact on the thermal justification of the doors because the dimensions of the shoulders are negligible in relation to the ri bs and the increase of the stamped parts represents only a 30% increase in their surface area.
- 9. Analysis of the impact of the presence of the smooth-walled dummy The material used in the smooth-walled dummy (sta inless steel) and its dimensions have no impact on the maximum temperature reached during the regulat ory fire test by the claddings of the EPR fuel assembly located within the second cavity of t he FCC4 packaging (moreover, the thermal model of the fire test in Appendix 2.2-1 only models a single cavity).
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 13 of 14
- 10. Conclusion
The maximum temperature reached by the FCC3 and FCC4 packaged under normal conditions of transport was °C.
The calculations carried out to determine the maximum temperatures reached by the fuel rod claddings under accidental conditions of transport showed that 3 fuel rod claddings reached temperatures over 600 °C.
The thermal-mechanical analysis carried out on these 3 fuel rods show that the risk of bursting of the Zircaloy-4 and M5Framatome cladding, due to creep, can be ruled out wi th a minimum safety factor of 3.3.
There is therefore no dispersal of material on completion of the test representative of accidental conditions of transport.
The deformation of the claddings, caused by the mechanical drop tests, has no impact on their thermal-mechanical strength during the thermal fire test.
The increased heat caused by the potential combustion of the wood in the shock-absorbers used in FCC3 and FCC4 packagings is covered by the assu mptions used in the calculation of the maximum cladding temperatures, deter mined in Appendix 2.2-1.
The study carried out on the potential combustion of 5 g of glycerine contained in the FCC3 and FCC4 packages shows that the impact upon the creep behaviour of the rods is negligible and does not affect the thermal-mechanical analyses detailed in the chapter.
The adaptation of the doors for the system holding the EPR fuel assembly grids in place, as opposed to the conventional doors used for XL/GAIA and XLR assemblies, makes no difference to the chapters thermal analyses.
The possible presence of the smooth-walled dummy has no impact on the chapters thermal analyses.
- 11. References
<1> Regulations for the Safe Transport of Radioactive Materials - at the revision indicated in Chapter 1.2.
<2> <2>High Temperature Materials (HiTemp 2011 ) Conference organised by Netzsch, Boston, MA, USA, (20-22 Sept. 2011)
<3> Zircaloy-4 and M5 high temperature oxidation and nitridin g in air, Duriez, C. and Dupont, T.
and Schmet, B. and Enoch, F., Journal of Nuclear Materials, 2008
Non-proprietary version Formulaire : PM04-4-MO-6 rév. 03 Unrestricted Orano Orano NPS Identification : DOS-19-021165-013-NPV Vers. 1.0 Page 14 of 14
List of Appendices
Appendix Title Number of pages
2.2-1 Framatome document - D02-ARV-01-167-814 Revision A "Justification by CFD simulation of the thermal resistant of FCC package during fire test" 2 + 115
2.2-2 Deletion of the Appendix -
2.2-3 Framatome document - "Fuel rod behaviour during IAEA thermal test in container " 37
2.2-4 TRANSNUCLEAIRE report 10373-B Rev. 3 "Summary note on the characterisation of FS 69 resin" 2 + 10
2.2-5 AREVA TN document - Analysis of the impact of glycerine on the thermal safety analyses 21
2.2-6 AREVA TN document - FCC package thermal behaviour in normal condition of transport 12 I >----------------------+---------I TOTAL 199
Non-proprietary version