Other: ML22277A727, ML22277A728, ML22277A729, ML22277A730, ML22277A733, ML22277A734, ML22277A735, ML22277A736, ML22277A737, ML22277A738, ML22277A739, ML22277A740, ML22277A741, ML22277A742, ML22277A743, ML22277A744, ML22277A745, ML22277A746, ML22277A747, ML22277A748, ML22277A749, ML22277A750, ML22277A751, ML22277A752, ML22277A753, ML22277A754, ML22277A755, ML22277A757, ML22277A758, ML22277A759, ML22277A760, ML22277A761, ML22277A762, ML22277A763, ML22277A764, ML22277A765, ML22277A766, ML22277A767, ML22277A768, ML22277A769, ML22277A770, ML22277A771, ML22277A772, ML22277A773, ML22277A774, ML22277A775, ML22277A776, ML22277A777, ML22277A778, ML22277A779... further results
|
MONTHYEARML22277A7611998-08-19019 August 1998 E-61285, Enclosure 4, 009h1 Appendix 2.1-8, Document No. TFXDC2108, Modified RCC Container - Proto 2 - Regulatory Test Programme (Public) Project stage: Other ML22277A7592004-05-0505 May 2004 E-61285, Enclosure 4, 009g1 Appendix 2.1-7, Document No. TFXEDC2104, Revision E, Modification of RCC Containers Choice of Prototype 2 Drop Configurations for Regulatory Tests (Public) Project stage: Other ML22277A7832004-10-29029 October 2004 E-61285, Enclosure 4, 013c1 Appendix 2.5-3, Document No. FF/DC/01106 E0, Revision a, Safety/Criticality Study of FCC3v2 Containers 14 X 14 8 Foot and 14 X 14 10 Footassemblies (FCC-3/FCC-4) (Public) Project stage: Other ML22277A7852007-12-19019 December 2007 E-61285, Enclosure 4, 013d1 Appendix 2.5-4, Document No. FF/DC/04191, Revision B, Safety/Criticality Study for FCC4 Packages & 17x17XL Assemblies Justification for an Increased Cavity Cross Section (Public) Project stage: Other ML22277A7512009-01-0101 January 2009 E-61285, Enclosure 4, 009c1 Ap 2.1-3 Document No. NTC-08-00135891E-NPV, Revision 01E, Analysis of the Fatigue Strength of the FCC3/FCC4 Containers (Public) Project stage: Other ML22277A7732009-06-27027 June 2009 E-61285, Enclosure 4, 010d1 Appendix 2.2-4, Document No. NTC-08-00118662E-NPV, Revision 1E, Note on the Characterization of Resin Fs 69 (Public) Project stage: Other ML22277A7492012-01-18018 January 2012 E-61285, Enclosure 4, 009b1 Appendix 2.1-2, Document No. NEEL-F 2008 DC 118, Revision B E1 (Npv), FCC4 Containers for Fresh Fuel Assemblies Data for the Fatigue Strength Analysis of the Lifting Boxes and Upper Shell (Public) Project stage: Other ML22277A7722012-04-0202 April 2012 E-61285, Enclosure 4, 010d Appendix 2.2-4, Document No. DOS-13-00081778-204-NPV, Revision 00, Reference to 10373-B-1, Revision 3, Summary Note on the Characterisation of Fs 69 Resin (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7382012-04-0202 April 2012 E-61285 Enclosure 4, 003d Appendix 1.4-4, Document No. DOS-13-00081778-044-NPV, Rev. 00, Reference to Photographs_FCC4, Rev. 0, Photographs of the FCC4 Package (Public) Project stage: Other ML22277A7622012-04-0202 April 2012 E-61285, Enclosure 4, 009i Appendix 2.1-9, Document No. DOS-13-00081778-109-NPV, Revision 00, Reference to Tfx DC 2087, Revision a, Container Prototype n°1 – Drop Test Report (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7972012-04-0202 April 2012 E-61285 Enclosure 4, 002d Appendix 1.3-4, Document No. DOS-13-00081778-034-NPV, Rev. 00, Reference to SQ/95/602PBO/CC, Revision 0,, Leaching Tests on Enriched Reprocessed Uranium (Eru) Pellets (Public) Project stage: Other ML22277A7822012-04-0202 April 2012 E-61285, Enclosure 4, 013c Appendix 2.5-3, Document No. DOS-13-00081778-503-NPV, Revision 00, Reference to Ffdc 01106, Revision a, Criticality-safety Analysis of FCC3 Containers Version 2-Assembly Types 14x14 8-foot and 14x14 10-ft (FCC-3/F Project stage: Other ML22277A7482012-04-0202 April 2012 E-61285, Enclosure 4, 009b Appendix 2.1-2, Document No. DOS-13-00081778-102-NPV, Rev 00, Reference to NEEL-F 2008 DC 118, Rev. B, FCC4 Containers for Fresh Fuel Assemblies – Data for Fatigue Resistance Analysis of Lifting Boxes and Upper Sh Project stage: Other ML22277A7602012-04-0202 April 2012 E-61285, Enclosure 4, 009h Appendix 2.1-8, Document No. DOS-13-00081778-108-NPV, Revision 00, Reference to Tfx DC 2108, Revision B, Modified RCC Container - Prototype 2 - Regulatory Test Programme (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7582012-04-0202 April 2012 E-61285, Enclosure 4, 009g Appendix 2.1-7, Document No. DOS-13-00081778-107-NPV, Revision 00, Reference to Tfxedc 2104, Revision E, Modification of RCC Containers - Selection of Drop Configurations for Prototype 2 in the Context of Regulato Project stage: Other ML22277A7632012-04-0202 April 2012 E-61285, Enclosure 4, 009j Appendix 2.1-10, Document No. DOS-13-00081778-110-NPV, Revision 00, Reference to Tfxe DC 2132, Revision B, Container Prototype No. 2 – Drop Test Report (FCC-3 - FCC4) (Public) Project stage: Other ML22277A7842012-09-0303 September 2012 E-61285, Enclosure 4, 013d Appendix 2.5-4, Document No. DOS-13-00081778-504-NPV, Rev. 00, Reference to Ffdc 04191, Rev. B, Safety/Criticality Study for FCC4 Packages, 17x17 Xl Assemblies Justification for an Increased Cavity Cross (FCC-3/FC Project stage: Other ML22277A7472015-06-0909 June 2015 E-61285, Enclosure 4, 009a1 Ap 2.1-1 Document No. FFDC05091, Revision B (Npv, English), FCC-4 Lashing Diagrams (Public) Project stage: Other ML22277A7742015-12-0101 December 2015 E-61285, Enclosure 4, 010e Appendix 2.2-5, Document No. DOS-13-00081778-205-NPV, Revision 00, Analysis of the Impact of Glycerine on the Thermal Safety Analyses (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7662016-09-0101 September 2016 E-61285, Enclosure 4, 009m Appendix 2.1-13, Document No. DOS-13-00081778-113-NPV, Revision 2, Complementary Analysis of FCC Package Behaviour in Accidental Drop Conditions (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7642018-05-18018 May 2018 E-61285 Enclosure 4, 009k Ap 2.1-11 DOS-19-021165-011-NPV, Version 1.0, Justification of the Performance of the FCC3 Shell Fasteners During a 9m Vertical Drop (FCC-3/FCC-4) (Public) Project stage: Other ML22277A7572021-10-28028 October 2021 E-61285 Enclosure 4, 009f1 Ap 2.1-6 FFDC04223-EN Npv Revision 4.0, Transportation in FCC Container Mechanical Aspects Related to a Change in the Fuel Assembly Materials (FCC-3/FCC-4) (Public) Project stage: Other ML22277A7702022-04-29029 April 2022 E-61285, Enclosure 4, 010a1 Appendix 2.2-1, Document No. FFP_D02-ARV-01-198-455, Justification by CFO Simulation of the Thermal Behavior of the FCC Container - FCC (Public) Project stage: Other ML22277A7342022-05-23023 May 2022 E-61285 Enclosure 4, Chapter 1.4, Document No. DOS-19-021166-005-NPV, Version 1.0, Specification Relating to the Packaging (Public) Project stage: Other ML22277A7962022-06-0303 June 2022 E61285 Enclosure 4, 002c1 Appendix 1.3-3, Document No. FFDC05098-EN, Revision 3.0, Impact Strength of Zr Alloys Proposal for the Specification of the Cladding Materials in the Shipment Approval (Public) Project stage: Other ML22277A7272022-06-13013 June 2022 E-61285 Enclosure 1, French Approval Certificate of a Package Design, Number F/348/AF-96 (Revision Gw), English Project stage: Other ML22277A7282022-06-13013 June 2022 E-61285 Enclosure 2, French Approval Certificate of a Package Design, Number F/348/AF-96 (Revision Gw), French (Public) Project stage: Other ML22277A7292022-08-0202 August 2022 E-61285 Enclosure 5 Orano NPS Statement of Proprietary Information, FCC-4 Application Submitted on August 18, 2022 (Public) Project stage: Other ML22277A7782022-08-0303 August 2022 E-61285, Enclosure 4, 013a Appendix 2.5-1, Doc. No. DOS-19-021165-015-NPV, Version 1.0, Ref. to Ffdc 00817 E0, Version 4.0, Safety/Criticality Study of FCC3 and FCC4 containers-15x15 and 17x17 assemblies-7x17 Xl, 17x17 EPR, 16x16 and 18x1 Project stage: Other ML22277A7792022-08-0303 August 2022 E-61285, Enclosure 4, 013a1 Appendix 2.5-1, Document No. FF/DC/00817 E0, Revision 4.0, Safety/Criticality Study of FCC3 and FCC4 Containers 15x15 and 17x17 Assemblies 17x17 Xl, 17x17 EPR, 16x16 and 18x18 Assemblies (Public) Project stage: Other ML22277A7922022-08-0303 August 2022 E-61285 Enclosure 4, 002 Chapter 1.3, Document No. DOS-19-021166-002-NPV, Version 2.0, Specifications Relating to Radioactive Content (Public) Project stage: Other ML22277A7772022-08-0303 August 2022 E-61285, Enclosure 4, 013 Chapter 2.5, Document No. DOS-19-021165-014-NPV, Version 1.0, Criticality-Safety Analysis (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7862022-08-0303 August 2022 E-61285, Enclosure 4, 013e Appendix 2.5-5, Document No. DOS-13-00081778-505-NPV, Rev. 00, Reference to FS1-001285, Criticality-Safety Study FCC4 Containers Justification of the Increase in the Cross Section of the Cavity (FCC-3/FCC-4 (Publi Project stage: Other ML22277A7692022-08-0303 August 2022 E-61285, Enclosure 4, 010a Appendix 2.2-1, Document No. DOS-19-021165-018-NPV, Version 1.0, SAR, Reference to D02-ARV-01-198-455, Revision a, Justification by Cfd Simulation of the Thermal Behavior of the FCC Container (FCC-3 and FCC-4) (Pu Project stage: Other ML22277A7902022-08-0303 August 2022 E-61285 Enclosure 4, 000 Document No. DOS-19-021166-000-NPV, Revision 2.0, Table of Contents, Orano NPS Safety Analysis Report for FCC-4 and the Reference Documents (Public) Project stage: Other ML22277A7762022-08-0303 August 2022 E-61285, Enclosure 4, 012 Chapter 2.4, Document No. DOS-13-00081778-400-NPV, Revision 1, Analysis of External Dose Rates (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7952022-08-0303 August 2022 E-61285 Enclosure 4, 002c Appendix 1.3-3, Document No. DOS-19-021165-021-NPV, Version 1.0, Safety Analysis Report, FCC-3 and FCC-4, Reference to Ffdc 05098 EN, Version 3.0, Impact Strength of Zr Alloys...(Public) Project stage: Other ML22277A7932022-08-0303 August 2022 E-61285 Enclosure 4, 002a Appendix 1.3-1, Document No. DOS-13-00081778-031-NPV, Rev. 1, Description of Red Boxes for FCC4 Containers (Public) Project stage: Other ML22277A7802022-08-0303 August 2022 E-61285, Enclosure 4, 013b Appendix 2.5-2, Document No. DOS-19-021165-01-NPV, Version 1.0, Reference to Ffdc 01046 E0, Version 3.0, Safety/Criticality Study of FCC3 and FCC4 containers-Transport of Fuel Rods in Boxes (Public) Project stage: Other ML22277A7872022-08-0303 August 2022 E-61285, Enclosure 4, 013e1 Appendix 2.5-5, Document No. FS1-0012857 E0, Revision 1, Safety Criticality Analysis, FCC4 Fuel Shipping Casks - Justification of the Enlarged Neutronic Cavity Section (Public) Project stage: Other ML22277A7442022-08-0303 August 2022 E-61285, Enclosure 4, 008 Chapter 1.9, Document No. DOS-19-021166-008-NPV, Version 1.0, Quality Assurance (Public) Project stage: Other ML22277A7812022-08-0303 August 2022 E-61285, Enclosure 4, 013b1 Appendix 2.5-2, Document No. FF/DC/01046 E0, Version 3.0, Safety/Criticality Study of FCC3 and FCC4 Containers Transport of Fuel Rods in Boxes (Public) Project stage: Other ML22277A7552022-08-0303 August 2022 Enclosure 4, 009e1 Appendix 2.1-5, Document No. Ffp D02-ARV-01-186-618-NPV, Revision a, FCC 4 - Containers for Fresh Fuel Assemblies - Stacking Behaviour (Public) Project stage: Other ML22277A7942022-08-0303 August 2022 E-61285 Enclosure 4, 002b Appendix 1.3-2, Document No. DOS-13-00081778-032-NPV, Rev. 1, Drawing of Rod Boxes for FCC4 Containers, List of Drawings (Public) Project stage: Other ML22277A7502022-08-0303 August 2022 E-61285, Enclosure 4, 009c Appendix 2.1-3, Document No. DOS-13-00081778-103-NPV, Revision 00, Reference to NTC-08-00135891, Revision 1, Analysis of the Fatigue Behaviour of FCC3/FCC4 Containers, Tn International Document (Public) Project stage: Other ML22277A7682022-08-0303 August 2022 E-61285, Enclosure 4, 010 Chapter 2.2, Document No. DOS-19-021165-013-NPV, Version 1.0, Thermal Analysis (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7752022-08-0303 August 2022 E-61285, Enclosure 4, 010f Appendix 2.2-6, Document No. DOS-13-00081778-206-NPV, Revision 00, Thermal Behaviour of the FCC Packaging Under Normal Conditions of Transport (FCC-3 - FCC-4) (Public) Project stage: Other ML22277A7882022-08-0303 August 2022 E-61285, Enclosure 4, 013f Appendix 2.5-6, Document No. DOS-13-00081778-506-NPV, Rev. 00, Nuclear Logistics Operations, Reference to Ffdc 00561, Rev. 4, Critically Safety Study Transport Package for Fresh UO2 Fuel (Uncertainties) (FCC-3/FCC Project stage: Other ML22277A7422022-08-0303 August 2022 E-61285 Enclosure 4, 006 Chapter 1.7, Document No. DOS-19-021166-006-NPV, Version 1.0, Instruction for Use of Packaging (Old Reference: DOS-13-00081778-070) (Public) Project stage: Other ML22277A7402022-08-0303 August 2022 E-61285 Enclosure 4, 004 Chapter 1.5, Document No. DOS-19-021166-003-NPV, Version 2.0, Package Performance Characteristics (Public) Project stage: Other 2015-12-01
[Table View] |
Text
Non-proprietary version Form: PM04-4-MO-6 Rev. 00 AREVA TN AREVA UNRESTRICTED DISTRIBUTION NUCLEAR LOGISTICS OPERATIONS APPENDIX 2.2-6 THERMAL BEHAVIOUR OF THE FCC PACKAGING UNDER NORMAL CONDITIONS OF TRANSPORT SAFETY ANALYSIS REPORT FCC3 - FCC4 Prepared by Identification DOS-13-00081778-206-NPV Checked by Rev.
00 Page 1 / 12 TN International TableofContents Revisionshistory 2
- 1. Introduction 3
- 2. Calculationsapproachandmethods 3
- 3. Results 4
- 4. Conclusion 6
- 5. References 6
Listoffigures 8
Listoftables 11
A AREVA
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 2 of 12 Non-proprietary version Revisions history Rev.
Date Purpose and record of changes Prepared by / Checked by 0
First issue I I
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 3 of 12 Non-proprietary version
- 1.
Introduction The purpose of this analysis is to evaluate, using numerical calculations, the temperature of the FCC packaging under Normal Conditions of Transport (NCT)
- 2.
Calculations - approach and methods 2.1.
Software The calculations are carried out using the I-DEAS software interfaced with the thermal module TMG <1>.
2.2.
Model mesh & geometry The model used in this study is a 2D thermal model, representing a section of the uninterrupted section of the FCC4 packaging shell and internal fittings. The model details the plates, the resin of the frame and the doors, the fuel rod claddings, the guide tubes and the pellets, as per the models presented in Appendix 2.2-1.
As in Appendix 2.2-1, the sizes of the air inlet openings in the cavity of the internal fittings are, respectively, 7mm in the upper section and 5 mm in the lower.
The 17x17 rod array is represented in the calculation model. The geometry and meshing of the internal fittings and17x17 fuel rod array is presented in figure 1.
The geometry of the shell is modelled in accordance with drawing <2> in Appendix 1.4-1 of Chapter 1.4. As per this drawing, the outer radius of the upper shell is mm, the outer radius of the lower shell is mm. The calculation model also represents the air between the internal fittings and the packaging shell.
2.3.
Materials The characteristics of the materials used for the packaging, and the air, are given in tableau
- 1.
2.4.
Power levels The fresh UO2 pellets do not emit any power.
2.5.
Heat exchanges 2.5.1.
Conduction The conductive exchanges within the materials are calculated directly by the code <1>,
using the thermal conductivity of each material, given in Table tableau 1.
The gap between the claddings and the pellets is calculated using the geometric characteristics of the 17x17 array, taken from Chapter 2.2-1, and listed in the table below:
dC: External rod diameter (mm) e:
Thickness of claddings (mm) dP: Pellet diameter (mm)
Array pitch (mm) 12.6 The radial gap (noted j) between the claddings and the pellets is calculated using the following equation:
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 4 of 12 Non-proprietary version
2 for the 17x17 array.
The Contact Resistance value (Rc) is deduced using the equation:
Where helium = W.m-1.K-1. from tableau 1 Therefore, the contact resistance for a 17x17 array is as follows:
. /
2.5.2.
Convection The air surrounding the packaging shell is not represented. The heat exchanges, by convection, are modelled, using a coefficient of exchange: h = 1.4T1/3 W.m-2.K-1. The calculation is based upon correlations taken from <3>.
2.5.3.
Radiation
The radiative exchanges between the claddings and the plates of the internal fittings, and between the outer surface of the internal fittings and the shell of the packaging, are directly calculated using the code <1>. They are modelled using radiative boxes. The emissivity levels of the various materials are given in Table 1.
Radiative exchanges between the outer surfaces of the shell and the ambient air are modelled using a view factor of 1. The shell is covered, inside and out, with a paint coating, the emissivity of which is (conservative value from Appendix 2.2-1).
2.5.4.
Ambient The temperature of the ambient air is assumed to be 38°C.
2.5.5.
Exposure to sunlight The calculation is carried out for transient operating conditions with 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> of sunlight exposure per 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> period. (regulatory exposure over 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> followed by zero exposure for the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />). The exposure is defined below, as per Table 13 of
<4>:
The solar flux received by the upper (curved) section of the packaging shell is 400 W/m².
The solar flux received by the vertical walls and lower (curved) section of the packaging shell is 200 W/m².
The density of the solar flux received by a given surface is, where is the surface absorptivity and E the regulatory sunlight.
The absorptivity is conservatively considered as being equal to 1 (See tableau 1)
- 3.
Results
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 5 of 12 Non-proprietary version The following table gives the maximum temperatures reached by the shell and packaging in steady state transient operating conditions.
Structure Temperature Time Shell Tmax = °C 43,200 s External plates Tmax = °C 43,210 s Resin Tmax = °C Tavg max = °C 43,230 s 43,500 s Internal plates Tmax = °C 44,100 s Claddings Tmax = °C 44,100 s The figure below shows the changes in the maximum temperatures of the various components making up the packaging.
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 6 of 12 Non-proprietary version The figure below shows the range of packaging temperatures at the moment the temperature of the external plates of the doors on the internal fittings is maximum.
- 4.
Conclusion The maximum temperatures reached by the main components making up the FCC packaging under Normal Conditions of Transport and regulatory sunlight exposure are as follows:
External shell of the packaging, Tmax = °C, External plates of the internal fittings, Tmax = °C, Resin within the internal fittings, Tmax = °C, Fuel rod claddings, Tmax = °C.
- 5.
References
<1> Finite element calculation software NX I-DEAS 6.1 M1 interfaced with the thermal model TMG 6.0.1181 distributed by Siemens PLM software.
<2> Drawing of the FCC4 packaging with its shell, entitled: Container for two UO2 fuel assemblies, 14-foot model - 17 x 17 (Type XL and EPR) and reference 229 K 0602.
<3> Handbook of Transfer Fundamentals - W.M. ROHSENOW, J.P. HARTNETT, E.N. GANIC, Mc Graw Hill - 2nd Edition
<4> Regulations for the Safe Transport of Radioactive Materials - Requirements N° SSR 6 - at the revision indicated in Chapter 1.2.
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 7 of 12 Non-proprietary version
<5> Archiving CDE3040600 / Thermique / CAL-13-00078918-002-00 Model: FCC4_coque.
Part FE model FE study Description 2D model Basic configuration TRANSIENT 2D model of the FCC4 packaging in the shell, for thermal calculations under transient operating conditions
Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206-NPV Rev.:
00 Page 8 of 12 Non-proprietary version List of figures Figure Title Number of pages 1
Geometry of the internal fittings and array of fuel rods (17x17) for the FCC4 packaging 1
2 Meshing of the internal fittings and array of fuel rods (17x17) for the FCC4 packaging 1
TOTAL 2
Form: PM04-4-MO-6 Rev. 00 AREVA RESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206 Rev.:
00 Page 9 of 12 Non-proprietary version GEOMETRY OF THE INTERNAL FITTINGS AND ARRAY OF FUEL RODS (17X17) FOR THE FCC4 PACKAGING GEOMETRY OF THE INTERNAL FITTINGS:
GEOMETRY OF THE FUEL ROD ARRAY (17X17)
LU O::'.
- J C)
LL
Form: PM04-3-MO-3 Rev. 2 AREVA RESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206 Rev.:
00 Page 10 of 12 Non-proprietary version MESHING OF THE INTERNAL FITTINGS AND ARRAY OF FUEL RODS (17X17) FOR THE FCC4 PACKAGING N
w 0::::
- J C)
LL
Form: PM04-4-MO-6 Rev. 00 AREVA RESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206 Rev.:
00 Page 11 of 12 Non-proprietary version List of tables Table Title Number of pages 1
Properties of the materials used in the FCC4 packaging 1
TOTAL 1
Form: PM04-3-MO-3 Rev. 2 AREVA RESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:
DOS-13-00081778-206 Rev.:
00 Page 12 of 12 Non-proprietary version THERMAL PROPERTIES OF THE MATERIALS USED IN THE FCC4 PACKAGING Material Thermal conductivity (W m-1 K-1)
Specific heat Cp (J/kg K)
Den sity (kg/m3)
Emissivity Solar absorptivity Stainless steel 20°C 14.71 500 7800 1
200°C 17.30 Resin Zy-4 claddings 20°C 20°C 200°C 200°C UO2 20°C 9.9 20°C 234.6 10.410 200°C 7.1 200°C 277.8 Air 20°C 0.0256 1,150 200°C 0.0385 Helium 0.33 5.190 3.28
- The thermal inertia of air is ignored.
TABLEAU 1