ML22277A788

From kanterella
Jump to navigation Jump to search

E-61285, Enclosure 4, 013f Appendix 2.5-6, Document No. DOS-13-00081778-506-NPV, Rev. 00, Nuclear Logistics Operations, Reference to Ffdc 00561, Rev. 4, Critically Safety Study Transport Package for Fresh UO2 Fuel (Uncertainties) (FCC-3/FCC
ML22277A788
Person / Time
Site: 07103097
Issue date: 08/03/2022
From: Boyle R, Shaw D
TN Americas LLC
To:
Division of Fuel Management
Garcia-Santos N
Shared Package
ML22277A716 List: ... further results
References
CAC A33010, EPID L-2022-DOT-0008, E-61285
Download: ML22277A788 (2)


Text

Non-proprietary version Form: PM04-4-MO-6 Rev. 00 AREVA TN AREVA UNRESTRICTED DISTRIBUTION NUCLEAR LOGISTICS OPERATIONS APPENDIX 2.5-6 SAFETY ANALYSIS REPORT FCC3-FCC4 Prepared by Identification DOS-13-00081778-506-NPV Checked by Rev.

00 Page 1 / 2 TN International REFERENCE REVISION TITLE FFDC 00561 4.0 CRITICALITY-SAFETY STUDY Transport package for fresh UO2 fuel Determination of uncertainties to be applied to criticality studies performed with CRISTAL.

A AREVA

Form: PM04-4-MO-6 Rev. 00 AREVA UNRESTRICTED DISTRIBUTION AREVA TN NUCLEAR LOGISTICS OPERATIONS Identification:

DOS-13-00081778-506-NPV Rev.:

00 Page 2 of 2 Non-proprietary version Revisions history Rev.

Date Purpose and record of changes Prepared by / Checked by 00 See first page First issue I I