05000269/FIN-2008006-01: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 13: Line 13:
| identified by = NRC
| identified by = NRC
| Inspection procedure = IP 71111.21
| Inspection procedure = IP 71111.21
| Inspector = R Moore, D Jones, B Sherbin, D Mas,-Penaranda S, Kobylarz C, Peabody B, Desa
| Inspector = R Moore, D Jones, B Sherbin, D Mas-Penaranda, S Kobylarz, C Peabody, B Desai
| CCA = P.2
| CCA = P.2
| INPO aspect = PI.2
| INPO aspect = PI.2

Latest revision as of 19:36, 20 February 2018

01
Site: Oconee Duke Energy icon.png
Report IR 05000269/2008006 Section 1R21
Date counted Mar 31, 2008 (2008Q1)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: NRC identified
Inspection Procedure: IP 71111.21
Inspectors (proximate) R Moore
D Jones
B Sherbin
D Mas-Penaranda
S Kobylarz
C Peabody
B Desai
CCA P.2, Evaluation
INPO aspect PI.2
'