IR 05000335/2014404: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
Line 23: Line 23:
Mano Nazar NextEra Energy P. O. Box 14000 700 Universe Boulevard Juno Beach, FL 33408-0420
Mano Nazar NextEra Energy P. O. Box 14000 700 Universe Boulevard Juno Beach, FL 33408-0420


SUBJECT: ST. LUCIE NUCLEAR PLANT - NRC TEMPORARY INSTRUCTION 2515/186 INSPECTION REPORT 05000335/2014404 AND 05000389/2014404
SUBJECT: ST. LUCIE NUCLEAR PLANT - NRC TEMPORARY INSTRUCTION 2515/186 INSPECTION REPORT 05000335/2014404 AND 05000389/2014404


==Dear Mr. Nazar:==
==Dear Mr. Nazar:==
Line 34: Line 34:
nuclear industry's readiness to safely respond to similar events. These results will also help the NRC to determine if additional regulatory actions are warranted. The NRC inspectors did not identify any findings or violations of more than minor significance.
nuclear industry's readiness to safely respond to similar events. These results will also help the NRC to determine if additional regulatory actions are warranted. The NRC inspectors did not identify any findings or violations of more than minor significance.


In accordance with Title 10 of the Code of Federal Regulations 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1).
In accordance with Title 10 of the Code of Federal Regulations 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1).


In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.


Sincerely,/RA/
Sincerely,/RA/
Eugene F. Guthrie, Chief Operations Branch 2       Division of Reactor Safety Docket No. 50-335, 50-389 License No. DPR-67, NPF-16  
Eugene F. Guthrie, Chief Operations Branch 2 Division of Reactor Safety Docket No. 50-335, 50-389 License No. DPR-67, NPF-16  


===Enclosure:===
===Enclosure:===
Line 45: Line 45:


===w/Attachment:===
===w/Attachment:===
Supplementary Information (Official Use Only) cc: (See page 3)
Supplementary Information (Official Use Only) cc: (See page 3)
}}
}}

Revision as of 21:09, 18 February 2018

IR 05000335-14-404 and 05000389-14-404, St. Lucie Nuclear Plant NRC Temporary Instruction 2515/186
ML14092A539
Person / Time
Site: Saint Lucie  NextEra Energy icon.png
Issue date: 03/28/2014
From: Guthrie E F
Division of Reactor Safety II
To: Nazar M K
Nextera Energy
References
IR-14-404
Download: ML14092A539 (5)


Text

March 28, 2014

Mano Nazar NextEra Energy P. O. Box 14000 700 Universe Boulevard Juno Beach, FL 33408-0420

SUBJECT: ST. LUCIE NUCLEAR PLANT - NRC TEMPORARY INSTRUCTION 2515/186 INSPECTION REPORT 05000335/2014404 AND 05000389/2014404

Dear Mr. Nazar:

On February 28, 2014, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your St. Lucie Nuclear Plant using Temporary Instruction 2515/186, "Inspection of Procedures and Processes for Responding to Potential Aircraft Threats". On February 28, 2014, the NRC inspector discussed the results of this inspection with Mr. Joe Jensen and other members of your staff. The inspector documented the results of this inspection in the enclosed inspection report.

The objective of this inspection was to assess the implementation procedures and processes of St. Lucie Nuclear Plant that are required by Title 10 of the Code of Federal Regulations (CFR), Part 50.54(hh)(1), which provides the requirements for responding to a potential aircraft threat.

The results from this inspection, along with the results from this inspection performed at other operating commercial nuclear plants in the United States, will be used to evaluate the U.S.

nuclear industry's readiness to safely respond to similar events. These results will also help the NRC to determine if additional regulatory actions are warranted. The NRC inspectors did not identify any findings or violations of more than minor significance.

In accordance with Title 10 of the Code of Federal Regulations 2.390, "Public Inspections, Exemptions, Requests for Withholding," of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC's Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, the material enclosed herewith contains Security-Related Information in accordance with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security vulnerability. Therefore, the material in the enclosure will not be made available electronically for public inspection in the NRC Public Document Room or from the PARS component of NRC's ADAMS. If you choose to provide a response and Security-Related Information is necessary to provide an acceptable response, please mark your entire response "Security-Related Information - Withhold from public disclosure under 10 CFR 2.390" in accordance with 10 CFR 2.390(d)(1) and follow the instructions for withholding in 10 CFR 2.390 (b)(1).

In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.

Sincerely,/RA/

Eugene F. Guthrie, Chief Operations Branch 2 Division of Reactor Safety Docket No. 50-335, 50-389 License No. DPR-67, NPF-16

Enclosure:

Inspection Report 05000335/2014404, 05000389/2014404

w/Attachment:

Supplementary Information (Official Use Only) cc: (See page 3)