ML063170083: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML063170083
| number = ML063170083
| issue date = 11/07/2006
| issue date = 11/07/2006
| title = Dresden, Unit 3 - Technical Specification, 2.0 Safety Limits
| title = Technical Specification, 2.0 Safety Limits
| author name = Honcharik J
| author name = Honcharik J
| author affiliation = NRC/NRR/ADRO/DORL/LPLIII-2
| author affiliation = NRC/NRR/ADRO/DORL/LPLIII-2
| addressee name = Crane C M
| addressee name = Crane C
| addressee affiliation = Exelon Generation Co, LLC
| addressee affiliation = Exelon Generation Co, LLC
| docket = 05000249
| docket = 05000249
| license number = DPR-025
| license number = DPR-025
| contact person = Williams J F, NRR/DLPM/LPD1, 415-1470
| contact person = Williams J, NRR/DLPM/LPD1, 415-1470
| case reference number = TAC MD2706
| case reference number = TAC MD2706
| package number = ml062990294
| package number = ml062990294
Line 19: Line 19:


=Text=
=Text=
{{#Wiki_filter:SLs 2.0 2.0 SAFETY LIMITS (SLs)2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow: THERMAL POWER shall be s 25% RTP.2.1.1.2 With the reactor steam dome pressure 785 psig and core flow 10% rated core flow: For Unit 2 be  1.11, MCPR shall For Unit 3 be 1.12, MCPR shall two recirculation loop operation, MCPR shall or for single recirculation loop operation, be 1.12.two recirculation loop operation, MCPR shall or for single recirculation loop operation, be R t e 1.14.I 2.1.1.3 Reactor vessel water level shall be greater than the top of. active irradiated fuel.2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be : 1345 psig.2.2 SL Violations With any SL violation, the following actions shall be completed within.2 hours: 2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.Dresden 2 and 3 2.0-1 Amendment No. 199/213}}
{{#Wiki_filter:SLs 2.0 2.0   SAFETY LIMITS (SLs) 2.1   SLs 2.1.1   Reactor Core SLs 2.1.1.1   With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:
THERMAL POWER shall be s 25% RTP.
2.1.1.2   With the reactor steam dome pressure &#x17d; 785 psig and core flow &#x17d; 10% rated core flow:
For Unit 2 two recirculation loop operation, MCPR shall be &#x17d; 1.11, or for single recirculation loop operation, MCPR shall be &#x17d; 1.12.
For Unit 3 two recirculation loop operation, MCPR shall be &#x17d; 1.12, or for single recirculation loop operation, MCPR shall be R te1.14.                                       I 2.1.1.3   Reactor vessel water level shall   be greater than the top of. active irradiated fuel.
2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be : 1345 psig.
2.2   SL Violations With any SL violation,     the following actions shall be completed within
    .2 hours:
2.2.1 Restore compliance with all SLs; and 2.2.2   Insert all   insertable control   rods.
Dresden 2 and 3                           2.0-1                       Amendment No. 199/213}}

Latest revision as of 12:06, 23 November 2019

Technical Specification, 2.0 Safety Limits
ML063170083
Person / Time
Site: Dresden Constellation icon.png
Issue date: 11/07/2006
From: John Honcharik
NRC/NRR/ADRO/DORL/LPLIII-2
To: Crane C
Exelon Generation Co
Williams J, NRR/DLPM/LPD1, 415-1470
Shared Package
ml062990294 List:
References
TAC MD2706
Download: ML063170083 (1)


Text

SLs 2.0 2.0 SAFETY LIMITS (SLs) 2.1 SLs 2.1.1 Reactor Core SLs 2.1.1.1 With the reactor steam dome pressure < 785 psig or core flow < 10% rated core flow:

THERMAL POWER shall be s 25% RTP.

2.1.1.2 With the reactor steam dome pressure Ž 785 psig and core flow Ž 10% rated core flow:

For Unit 2 two recirculation loop operation, MCPR shall be Ž 1.11, or for single recirculation loop operation, MCPR shall be Ž 1.12.

For Unit 3 two recirculation loop operation, MCPR shall be Ž 1.12, or for single recirculation loop operation, MCPR shall be R te1.14. I 2.1.1.3 Reactor vessel water level shall be greater than the top of. active irradiated fuel.

2.1.2 Reactor Coolant System Pressure SL Reactor steam dome pressure shall be : 1345 psig.

2.2 SL Violations With any SL violation, the following actions shall be completed within

.2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />s:

2.2.1 Restore compliance with all SLs; and 2.2.2 Insert all insertable control rods.

Dresden 2 and 3 2.0-1 Amendment No. 199/213