{{#Wiki_filter:11921 Rockville Pike, Suite 100, Rockville, MD  20852 Phone: 301-984-4400, Fax: 301-984-7600 Email: tstf@excelservices.com Administered by EXCEL Services Corporation TECHNICAL SPECIFICATIONS TASK FORCE A JOINT OWNERS GROUP ACTIVIT Y TSTF November 28, 2006 TSTF-06-33 PROJ0753
{{#Wiki_filter:TECHNICAL SPECIFICATIONS TASK FORCE TSTF                                          A JOINT OWNERS GROUP ACTIVITY November 28, 2006                                                               TSTF-06-33 PROJ0753 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001
 
U. S. Nuclear Regulatory Commission Attn: Document Control Desk  
 
Washington, DC 20555-0001  


==SUBJECT:==
==SUBJECT:==
Withdrawal of TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed"
Withdrawal of TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed"


==Dear Sir or Madam:==
==Dear Sir or Madam:==


On October 25, 2005, the TSTF submitted TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal w ith Upper Internals Inst alled." Upon further consideration, the TSTF withdraws TSTF-492 from NRC consideration.  
On October 25, 2005, the TSTF submitted TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed." Upon further consideration, the TSTF withdraws TSTF-492 from NRC consideration.
 
Should you have any questions, please do not hesitate to contact us.
Should you have any questions, please do not hesitate to contact us.  
Wesley Sparkman (PWROG/W)                           Michael Crowthers (BWROG)
 
Brian Woods (PWROG/CE)                               Paul Infanger (PWROG/B&W)
Wesley Sparkman (PWROG/W) Michael Crowthers (BWROG)  
Enclosure cc:     Tim Kobetz, Technical Specifications Branch, NRC Ross Telson, Technical Specifications Branch, NRC 11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Email: tstf@excelservices.com Administered by EXCEL Services Corporation}}
 
Brian Woods (PWROG/CE) Paul Infanger (PWROG/B&W)  
 
Enclosure  
 
cc: Tim Kobetz, Technical Specifications Branch, NRC Ross Telson, Technical Specifications Branch, NRC}}

Latest revision as of 12:44, 23 November 2019

Withdrawal of TSTF-492, Revision 0, Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed.
ML063330090
Person / Time
Site: Technical Specifications Task Force
Issue date: 11/28/2006
From: Crowthers M, Infanger P, Sparkman W, Woods B
BWR Owners Group, PWR Owners Group, Technical Specifications Task Force
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
TSTF-06-33
Download: ML063330090 (1)


Text

TECHNICAL SPECIFICATIONS TASK FORCE TSTF A JOINT OWNERS GROUP ACTIVITY November 28, 2006 TSTF-06-33 PROJ0753 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Withdrawal of TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed"

Dear Sir or Madam:

On October 25, 2005, the TSTF submitted TSTF-492, Revision 0, "Modify RHR - High Water Level Bases to Address Decay Heat Removal with Upper Internals Installed." Upon further consideration, the TSTF withdraws TSTF-492 from NRC consideration.

Should you have any questions, please do not hesitate to contact us.

Wesley Sparkman (PWROG/W) Michael Crowthers (BWROG)

Brian Woods (PWROG/CE) Paul Infanger (PWROG/B&W)

Enclosure cc: Tim Kobetz, Technical Specifications Branch, NRC Ross Telson, Technical Specifications Branch, NRC 11921 Rockville Pike, Suite 100, Rockville, MD 20852 Phone: 301-984-4400, Fax: 301-984-7600 Email: tstf@excelservices.com Administered by EXCEL Services Corporation