{{#Wiki_filter:Attachment 6 OBDI 202 - IOLE Process Rev 1 DRAFT OUTLINE COMMENTS Facility: FCS   First Exam Date:   Written Exam Outline (Date) Comment Resolution 1 NRC Generated 2   3   4   5     Administrative JPM Outline (Date) Comment Resolution 1 SRO JPM S5 needs to be time critical Made JPM S5 time critical 2   3   4   5 Control Room / In-Plant System JPM Outline (Date) Comment Resolution 1 JPM S2 appears to have been on the last initial exam Changed annotation of S2 to "modified" JPM 2   3   4 Simulator Scenario Outline Comments (Date) Comment Resolution 1 Scenario 4 Event 7 appears to be the same thing as written question 47 Replaced written question 47 (?) 2   3   4   5 Attachment 6 OBDI 202 - IOLE Process Rev 1 DRAFT OUTLINE COMMENTS Facility: FCS   First Exam Date:   Written Exam Outline (Date) Comment Resolution 1 NRC Generated 2   3   4   5     Administrative JPM Outline (Date) Comment Resolution 1 SRO JPM S5 needs to be time critical Made JPM S5 time critical 2   3   4   5 Control Room / In-Plant System JPM Outline (Date) Comment Resolution 1 JPM S2 appears to have been on the last initial exam Changed annotation of S2 to "modified" JPM 2   3   4 Simulator Scenario Outline Comments (Date) Comment Resolution 1 Scenario 4 Event 7 appears to be the same thing as written question 47 Replaced written question 47 (?) 2   3   4   5}}
{{#Wiki_filter:DRAFT OUTLINE COMMENTS Facility:           FCS                         First Exam Date:
Written Exam Outline (Date)
Comment                                 Resolution 1   NRC Generated 2
3 4
5 Administrative JPM Outline (Date)
Comment                                 Resolution 1   SRO JPM S5 needs to be time critical   Made JPM S5 time critical 2
3 4
5 Control Room / In-Plant System JPM Outline (Date)
Comment                                 Resolution JPM S2 appears to have been on the     Changed annotation of S2 to modified JPM 1
last initial exam 2
3 4
Simulator Scenario Outline Comments (Date)
Comment                                 Resolution Scenario 4 Event 7 appears to be the   Replaced written question 47 (?)
1 same thing as written question 47 2
3 4
5                   OBDI 202 - IOLE Process                             Rev 1
 
DRAFT OUTLINE COMMENTS Facility:           FCS                         First Exam Date:
Written Exam Outline (Date)
Comment                                 Resolution 1   NRC Generated 2
3 4
5 Administrative JPM Outline (Date)
Comment                                 Resolution 1   SRO JPM S5 needs to be time critical   Made JPM S5 time critical 2
3 4
5 Control Room / In-Plant System JPM Outline (Date)
Comment                                 Resolution JPM S2 appears to have been on the     Changed annotation of S2 to modified JPM 1
last initial exam 2
3 4
Simulator Scenario Outline Comments (Date)
Comment                                 Resolution Scenario 4 Event 7 appears to be the   Replaced written question 47 (?)
1 same thing as written question 47 2
3 4
5                   OBDI 202 - IOLE Process                            Rev 1}}

Latest revision as of 02:19, 31 October 2019

2015-12 Draft Outline Comments
ML16012A327
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 12/14/2015
From: Vincent Gaddy
Operations Branch IV
To:
Omaha Public Power District
References
Download: ML16012A327 (1)


Text

DRAFT OUTLINE COMMENTS Facility: FCS First Exam Date:

Written Exam Outline (Date)

Comment Resolution 1 NRC Generated 2

3 4

5 Administrative JPM Outline (Date)

Comment Resolution 1 SRO JPM S5 needs to be time critical Made JPM S5 time critical 2

3 4

5 Control Room / In-Plant System JPM Outline (Date)

Comment Resolution JPM S2 appears to have been on the Changed annotation of S2 to modified JPM 1

last initial exam 2

3 4

Simulator Scenario Outline Comments (Date)

Comment Resolution Scenario 4 Event 7 appears to be the Replaced written question 47 (?)

1 same thing as written question 47 2

3 4

5 OBDI 202 - IOLE Process Rev 1

DRAFT OUTLINE COMMENTS Facility: FCS First Exam Date:

Written Exam Outline (Date)

Comment Resolution 1 NRC Generated 2

3 4

5 Administrative JPM Outline (Date)

Comment Resolution 1 SRO JPM S5 needs to be time critical Made JPM S5 time critical 2

3 4

5 Control Room / In-Plant System JPM Outline (Date)

Comment Resolution JPM S2 appears to have been on the Changed annotation of S2 to modified JPM 1

last initial exam 2

3 4

Simulator Scenario Outline Comments (Date)

Comment Resolution Scenario 4 Event 7 appears to be the Replaced written question 47 (?)

1 same thing as written question 47 2

3 4

5 OBDI 202 - IOLE Process Rev 1