ML15161A176: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 3: Line 3:
| issue date = 05/21/2015
| issue date = 05/21/2015
| title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.1-001
| title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.1-001
| author name = Bynum R V
| author name = Bynum R
| author affiliation = Shine Medical Technologies, Inc
| author affiliation = Shine Medical Technologies, Inc
| addressee name =  
| addressee name =  

Revision as of 22:13, 20 June 2019

Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.1-001
ML15161A176
Person / Time
Site: SHINE Medical Technologies
Issue date: 05/21/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.18, SHN.PSAR.P, SHN.PSAR.P.8
Download: ML15161A176 (1)


Text

Figure 8a2.1 One-Line Diagram - Normal Electrical Power Supply System NOTES:1. BREAKERS DROP OUT (TRIP) ON LOSS OF POWER TO THE BUS AND CAN BE MANUALLY CLOSED SELECTIVELY AFTER SDG RESTORES POWER TO THE BUSES.2. SDG AND AUTOMATIC TRANSFER EQUIPMENT LOCATED IN SEPARATE BUILDING.

3. RESPECTIVE 480V AC SWGR BUS A OR B POWERS THE SDG BUSES DURING NORMAL OPERATION. ON LOSS OF OFF-SITE POWER, BOTH AC SWGR A AND B WILL BE CONNECTED AS NEEDED.4. ON LOSS OF OFF-SITE POWER SDG WILL START. AFTER RATED VOLTAGE AND FREQUENCY ARE ESTABLISHED AT THE SDG BUS, BREAKER FEEDS TO OTHER FACILITY LOADS WILL BE MANUALLY CONNECTED AS NEEDED.5. LOAD BREAKERS EQUIPPED WITH SOFT STARTERS.6. SDG - STANDBY DIESEL GENERATOR7. FIRE PUMP CONTROLLER BOX PER NFPA 20 AND IS LOCATED IN SIGHT OF FIRE PUMP ROOM.480V-208Y/120V75 kVA3PHDISTRIBUTION PANEL FOR TCAP 1, 2, 3 & 4CHILLER 1FACILITY 480V AC PLANT SWGR A208Y/120V 200A3PH, 4W12kV-480Y/277V2000 kVA 3PHTRANSFORMER OUTDOOR TYPE12kV UTILITY FEEDER CABLE BUSUTILITY INTERFACEZONE 1 EXHAUSTFAN A ZONE 2 EXHAUSTFAN A OUTDOOR NC M480V-208Y/120V75 kVA 3PHDISTRIBUTION PANEL FOR TCAP 5, 6, 7 & 8CHILLER 3 FACILITY 480V AC PLANT SWGR B208Y/120V 200A 3PH, 4W12kV-480Y/277V 2000 kVA3PHTRANSFORMER OUTDOOR TYPE12kV UTILITY FEEDERCABLE BUSUTILITY INTERFACEZONE 2 EXHAUSTFAN B(STANDBY)OUTDOOR NC M480VLATER kW 3PH, 4W NC NOBATTERYCHARGER ABATTERYCHARGER BNCNC NO NOPLUG-INPORTABLE DG FACILITY 480V AC SDG BUS A AT SWGR ROOM NOTE 3 NOTE 3 NCNOTE 4 LOCATED INSDG BUILDINGUPS VOLTAGEREGULATINGXFMR ASSEMBLY BUPS VOLTAGEREGULATINGXFMR ASSEMBLY A NC NC NC NCTO 480V AC MCC A1TO 480V ACMCC A2TO 480V AC MCC B1TO 480V ACMCC B2TO 480V ACSDG MCC B125 HP200 HP100 HP 200 HP100 HPSDGCHILLER 4 200 HPCHILLER 2200 HPEMERGENCYLIGHTINGPANELZONE 1EXHAUST FAN B(STANDBY)125 HP NCTO 480V ACSDG MCC A NCEMERGENCYLIGHTINGPANEL FACILITY 480V AC SDG BUS B AT SWGR ROOM NO OUTDOOR LOAD BANKFOR SDGTESTING NO NOFROM 480V AC SUPPLY SDG MCC A FIRE PUMP 200 HPFIRE PUMP ROOM(LOCATED OUTSIDE FACILITY)FIRE PUMPCONTROLLER BOX (NOTE 7) Chapter 8 - Electrical Power Systems Normal Electrical Power Systems SHINE Medical Technologies Rev. 0