Text

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Radioisotope Extraction System SHINE Medical Technologies Rev. 0 Figure 4b.3 Molybdenum Extraction Process Flow Diagram Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Radioisotope Extraction System SHINE Medical Technologies Rev. 0 Figure 4b.3 Purification Process Flow Diagram

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Uranyl Nitrate Preparation (UNP) Process Flow Diagram Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Uranium Extraction (UREX) Process Flow Diagram

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Thermal Denitration (TDN) Process Flow Diagram

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 TSPS General Arrangement Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Uranium Metal Storage Rack Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Uranium Oxide Storage Rack Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)

Security-Related Information - Withhold under 10 CFR 2.390

Chapter 4 - Irradiation Unit and Radioisotope Production Facility Description Special Nuclear Material Processing and Storage SHINE Medical Technologies Rev. 0 Figure 4b.4 Uranium Metal/Oxide Storage Rack Assembly Proprietary Information - Withhold from public disclosure under 10 CFR 2.390(a)(4)