Shine Medical Technologies V. 0 - Chapter 07 - Figures 7a2.1-001 Through 7a2.6-002
ML15258A404
Person / Time
Site: SHINE Medical Technologies
Issue date: 08/27/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.22, SHN.PSAR.P, SHN.PSAR.P.10
Download: ML15258A404 (7)


Text

Chapter 7 - Instrument & Control Systems Summary Description Figure 7a2.1 Safety Approach for TSV Shutdown Power Source Dedicated NOTrip Breaker Dedicated NOTrip Breaker Neutron Driver (NDAS)

Wiring Distribution Enclosure Neutron Flux Detector x3 Target Solution Vessel (TSV)

IU Cell Boundary Target Solution TSV A B Dump Valves TSV Inlet Isolation A B Valves Target Solution Dump Tank A

Dump Tank Outlet Isolation Valves B

Irradiated Target Solution TSV Reactivity TSV Process Neutron Flux Protection System Control System Detection System (TRPS) (TPCS)

Control Room Operator Interface Displays SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Design of Instrument and Control Systems Figure 7a2.2 I&C System Block Diagram for Irradiation Facility NonSafety Process Control Event Log Event Log Annunciator Detail DrillDown Annunciator Detail DrillDown Annuciator Annunciator Safety Display Display Display Display Related Display Display Engineered Safety TSV Reactivity TSV Process Control Engineered Safety Features Actuaton Protection System Isolated Links System Features Actuaton System (ESFASA) TRPS TPCS System (ESFASB)

Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Neutron Flux Detection Detection Detection Detection Detection Detection Detection Detection System System System System System System System System NFDS #1 NFDS #2 NFDS #3 NFDS #4 NFDS #5 NFDS #6 NFDS #7 NFDS #8 Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Neutron Driver Assembly Assembly Assembly Assembly Assembly Assembly Assembly Assembly System System System System System System System System NDAS NDAS NDAS NDAS NDAS NDAS NDAS NDAS SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical SubCritical Assembly Assembly Assembly Assembly Assembly Assembly Assembly Assembly System System System System System System System System SCAS SCAS SCAS SCAS SCAS SCAS SCAS SCAS IU Cell #1 IU Cell #2 IU Cell #3 IU Cell #4 IU Cell #5 IU Cell #6 IU Cell #7 IU Cell #8 SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 Typical ESF Circuit (L+) (O REF)

L1 N ESD PB TPCS Detector A Detector B A1 ESF A A2 A1 ESF A A2 OUT 1 Relay 1 Relay 2 SENSE 1 SENSE 1 RESET RESET SENSE 2 SENSE 2 OUT 2 Other Relay Relay Detectors Output Output C1 Coil Output ESF A Relay Relay IN 1 Monitor Monitor K1 K2 K1 K2 IN 2 RESET PB Other Relays in IU Cell Group SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 Example ESFAS Panel IU Cell #1 IU Cell #2 1

2 3

4 5

6 7

8 9

10 11 12 IU Cell #3 IU Cell #4 IU Cell #5 IU Cell #6 42in.

IU Cell #7 IU Cell #8 29in.

16in.

3in.

12" Above Floor 1 BubbleTight Inlet Damper Relays 7 Tritium Delivery Isolation Valve Relays 2 BubbleTight Outlet Damper Relays 8 Tritium Return Isolation Valve Relays 3 PCLS Inlet Isolation Valve Relays 9 TRPS Input Signal Trip Relays 4 PCLS Outlet Isolation Valve Relays 10 Spare 5 LWPS Inlet Isolation Valve Relays 11 Spare 0.0 in. 3.6 in. 6.0 in. 12.0 in.

6 LWPS Outlet Isolation Valve Relays 12 Spare SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Engineered Safety Features Actuation System Figure 7a2.5 ESFAS Manual Operator Panel IU Cell #1 IU Cell #2 IU Cell #3 IU Cell #4 Override Illumination OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE A B A B A B A B Tripped Illumination TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B ESD Pushbutton ESD A ESD B ESD A ESD B ESD A ESD B ESD A ESD B Reset Pushbutton RESET A RESET B RESET A RESET B RESET A RESET B RESET A RESET B Check Pushbutton BULB BULB BULB BULB CHECK CHECK CHECK CHECK IU Cell #5 IU Cell #6 IU Cell #7 IU Cell #8 39in.

OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE OVERRIDE A B A B A B A B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B TRPPED A TRPPED B 4' by 5' Panel ESD A ESD B ESD A ESD B ESD A ESD B ESD A ESD B 27in.

RESET A RESET B RESET A RESET B RESET A RESET B RESET A RESET B 19in.

BULB BULB BULB BULB CHECK CHECK CHECK CHECK 7in.

33" Above Ground 0.0 in. 3.6 in. 6.0 in. 12.0 in.

SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Control Console and Display Information Figure 7a2.6 Irradiation Facility Workstation Layout TRPS Fixed Status TPCS Fixed Status RICS Status Display Display Display TRPS Alarm/ Event TPCS Alarm/ Event RICS Alarm Display Display Display TRPS HMI TPCS HMI RICS HMI Display Display Display Keyboard Keyboard Keyboard SHINE Medical Technologies Rev. 0

Chapter 7 - Instrument & Control Systems Control Console and Display Information Figure 7a2.6 Control Room Layout Security-Related Information - Withhold under 10 CFR 2.390 SHINE Medical Technologies Rev. 0