Line 28: |
Line 28: |
| ==Dear Ms. Wendy Croft:== | | ==Dear Ms. Wendy Croft:== |
|
| |
|
| By letter dated May 7, 2014, (Agencywide Docu ment Access and Management System Accession No. ML14127A424) Exelon Generation Company, LLC submitted a license amendment request for Three Mile Island Nuclear Station Unit 1 (TMI-1). The proposed amendment would modify TMI-1 Technical Specification 4.12, Air Treatment System, by replacing an existing Surveillance Requirement to operate ventilation systems with charcoal filters for a 10-hour period every 31 days with a requirement to operate the systems for greater than or equal to 15 continuous minutes every 31 days in accordance with Technical Specification Task Force (TSTF) Traveler TSTF-522, Revision 0, "Revise Ventilation System Surveillance Requirements to Operate for [[estimated NRC review hours::10 hours]] per Month." | | By letter dated May 7, 2014, (Agencywide Docu ment Access and Management System Accession No. ML14127A424) Exelon Generation Company, LLC submitted a license amendment request for Three Mile Island Nuclear Station Unit 1 (TMI-1). The proposed amendment would modify TMI-1 Technical Specification 4.12, Air Treatment System, by replacing an existing Surveillance Requirement to operate ventilation systems with charcoal filters for a 10-hour period every 31 days with a requirement to operate the systems for greater than or equal to 15 continuous minutes every 31 days in accordance with Technical Specification Task Force (TSTF) Traveler TSTF-522, Revision 0, "Revise Ventilation System Surveillance Requirements to Operate for 10 hours per Month." |
| The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staff's acceptance review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. | | The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staff's acceptance review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. |
| The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. | | The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. |
Revision as of 21:58, 8 November 2018
Letter Sequence Acceptance Review |
---|
TAC:MF4110, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours PER Month (Open) |
|
|
|
---|
Category:Acceptance Review Letter
MONTHYEARML20042D4542020-02-11011 February 2020 Acceptance of Requested Licensing Action Exemption Request from 10 CFR 140.11(a)(4) Primary and Secondary Liability Insurance Requirements ML19347B0312019-12-12012 December 2019 Acceptance of Requested Licensing Action Amendment Request to Remove Permanently Defueled Technical Specification 3/4.1.4 ML14318A8302014-11-18018 November 2014 Acceptance of Requested Licensing Action License Amendment Request to Modify Reactor Coolant System Pressure Isolation Check Valve Technical Specification Maximum Allowable Leakage Limits ML14223B1222014-08-13013 August 2014 TMI, Unit 1 - Acceptance of Requested Licensing Action License Amendment Request to Revise Technical Specifications to Adopt TSTF-523 Generic Letter 2008-01, Managing Gas Accumulation, Rev 2, Using the Consolidated Line Item Improvement Pro ML14154A5212014-06-0303 June 2014 E-mail from Jwhited to Wcroft Three Mile Island Nuclear Station, Unit 1 - Acceptance of Requested Licensing Action Adoption of TSTF-522 ML1132900262011-11-25025 November 2011 E-mail, Miller to Loomis, TMI Acceptance Review of Relief Request PR-05 ML1129201242011-10-19019 October 2011 E-mail, Miller to Croft, TMI-1 LAR 11-103 Admin TS Changes Acceptance Review ML1030504512010-11-0101 November 2010 Acceptance Review of TMI-1 Relief Request RR-10-02, Weld Overlay of Pressurizer Spray Nozzle Welds - TAC No. ME4795 ML1030000302010-10-27027 October 2010 Acceptance Review of TMI-1 LAR Regarding Relocation of Equipment Load List to UFSAR - TAC ME4732 ML1029500362010-10-22022 October 2010 Acceptance Review of TMI-1 RR-10-01, Control Rod Drive Housing Examinations - TAC ME4882 ML1025905332010-09-16016 September 2010 Acceptance Review of TMI 4th Interval ISI Relief Requests I4R-01, I4R-03, I4R-04, I4R-05 and I4R-06 ML1008800852010-07-21021 July 2010 Fleet - Acceptance Review Implementation of Emergency Action Level Schemes Developed from NEI 99-01m Rev. 5 ML1011002162010-04-20020 April 2010 Acceptance Review for TMI-1 LAR Regarding Adoption of TSTF-425, Surveillance Frequency Control Program, TAC ME3587 ML0908503182009-03-26026 March 2009 Acceptance Review of Request to Use a Later Provision of ASME Code, Section XI Regarding Thermal Removal Processes 2020-02-11
[Table view] Category:E-Mail
MONTHYEARML24228A1922024-07-29029 July 2024 Request for Additional Information Response Due Date Extension E-Mail String ML24192A3642024-06-21021 June 2024 State Rad Health Reply Email Re Draft Environmental Assessment for the Three Mile Island Unit 2 ML24011A2332024-01-11011 January 2024 Request for Additional Information - License Amendment Request (ML23058A064) (EPID L-2023-LLA-0026 - Three Mile Island, U2: Amendment Historic and Cultural Resources) ML24130A2692023-08-30030 August 2023 TMI-2 Consultation Invitation Letter PSA Reply ML24130A2652023-08-21021 August 2023 TMI-2 Consultation Invitation Letter Reply from CAP ML23187A0202023-06-29029 June 2023 TMI Unit 2 RAI Related to the Amended Post-Shutdown Decommissioning Activities Report ML23135A3992023-05-12012 May 2023 (External_Sender) Section 106 Consultation - NRC NHPA for Three Mile Island Unit 2 ML23159A1642023-05-11011 May 2023 Email TMI-2 Pol Am. 67 SE Minor Discrepancies ML23107A2232023-04-14014 April 2023 Response Re State Consultation-TMI-2 Solutions - Draft EA Fonsi Criticality Exemption Request ML23094A1482023-03-30030 March 2023 TMI-2 TS 6.0 Draft Wording Agreement ML23090A2142023-03-30030 March 2023 Asnyder, NRC Email from Tdevik, Energysolutions, Three Mile Island, Unit 2 -Response Regarding MC&A TS Change, Modification ML23094A0602023-03-30030 March 2023 TMI-2 Response on Draft TS Wording ML23068A4682023-03-0909 March 2023 Response Re State Consultation - License Amendment Request TMI-2 Solutions - Update Technical Specifications and Remove Certain License Conditions Applicable to Pdms ML23057A0062023-02-24024 February 2023 State Consultation - License Amendment Request TMI-2 Solutions - Update Technical Specifications and Remove Certain License Conditions Applicable to Pdms ML23051A0412023-02-15015 February 2023 Email from TMI-2 Solutions Regarding Commitment Date, Dated 02/15/2023 ML22364A1942022-12-30030 December 2022 Email Mitigation for Hydrogen Concerns Commitment, Dated December 30, 2022 ML22357A0142022-12-22022 December 2022 NRC Request for Additional Information Related to the TMI-2 Pdms Transition License Amendment Request ML22321A0072022-11-16016 November 2022 Material Control and Accounting RAI Response Clarification Call Docket No 50-320 ML23069A1582022-09-22022 September 2022 NRC Response TMI-2 Solutions Exemption Question ML22214A0482022-08-0101 August 2022 TMI-2 Response: License Amendment Request TMI-2 Solutions Physical Materials Security Plan - Revised Modified License Condition 2.C(2) ML22208A0492022-07-21021 July 2022 State Consultation Response: License Amendment Request TMI-2 Solutions Physical Materials Security Plan ML22199A2762022-07-18018 July 2022 E-mail from A. Snyder, NRC, to B. Werner, PDEP, Regarding State Consultation Proposed Conforming Amendment Related to Proposed Exemption Request from Certain Record Retention Requirements ML22199A2772022-07-15015 July 2022 E-mail Attachment: Federal Register Notice - Volume 87 ML22189A2032022-07-0808 July 2022 E-mail from A. Snyder, NRC, to B. Werner, PA Department of Environment Protection - Three Mile Island, Unit 2 - State Consultation - License Amendment Request TMI-2 Solutions Physical Materials Security Plan ML22189A2042022-06-28028 June 2022 NRC-2022-0131-0001_Content - Federal Register Vol. 87, No. 123 ML22143A8902022-05-23023 May 2022 Request for Additional information- TMI-1 ISFSI Only Physical Security License Amendment Request ML22131A1382022-05-10010 May 2022 E-mail from T. Devik, Energysolutions TMI-2, to A. Snyder, NRC, Physical Security Plan May 9 Submittal Typo Correction ML22125A0162022-05-0303 May 2022 Email from T Devik to a Snyder: Three Mile Island 2 - Security Plan Proposed Revision License Condition 2.C.(2) (EPID: L-2021-LLA-0103) Proposed License Condition - May 3, 2022 Response Courtesy Copy ML22125A0102022-05-0303 May 2022 Proposed Action- Proposed Fonsi for TMI-1 Exemption Request from 10 CFR 50.82(a)(8)(i)(A) and 10 CFR 50.75(h)(1)(iv) Notification of Commonwealth of Pennsylvania Response ML22125A0092022-05-0303 May 2022 Proposed Action- Proposed Fonsi for TMI-1 Exemption Request from 10 CFR 50.82(a)(8)(i)(A) and 10 CFR 50.75(h)(1)(iv) Notification of Commonwealth of Pennsylvania ML22125A0132022-04-28028 April 2022 Security Plan Proposed Revision License Condition 2.C.(2) (EPID: L-2021-LLA-0103) Proposed License Condition - Partial Response ML22125A0122022-04-28028 April 2022 Clarification RAI Partial Response Email from C Smith to a Snyder ML22110A0212022-04-19019 April 2022 Security Plan Proposed Revision License Condition 2.C.(2) (EPID: L-2021-LLA-0103) Proposed License Condition ML22110A0202022-04-19019 April 2022 Unit 1 Request for Additional Information ML22108A1762022-04-14014 April 2022 E-mail: Proposed Order Conditions for In-Direct Transfer of Licenses Held by Energysolutions, LLC (Zion, TMI Unit-2, La Crosse Boiling Water Reactor, Kewaunee, Energysolutions Radioactive Materials License, and Energysolutions Export Licens ML22102A3062022-03-31031 March 2022 Email from T. Divik, Energy Solutions, to A. Snyder Clarification of Security License Condition Amendment Request ML22094A1812022-03-22022 March 2022 Licensee High Confidence Dates for Submittals ML22108A1022022-03-18018 March 2022 Email from A. Snyder, NRC to G. Van Noordennen, Energy Solutions, Clarification Request - September 21, 2021 Supplement- TMI-2 Physical Security Plan LAR ML22090A0142022-03-17017 March 2022 TMI, Unit 1 - Commonwealth of PA Response to Request for Consultation on the Proposed Revision to the License and the Permanently Defueled Technical Specifications to Align to the Requirements for Permanent Removal of Spent Fuel from the Sp ML22070A1202022-03-10010 March 2022 E-mail from S. Acker, PADEP, to A. Snyder, NRC - Three Mile Island Unit 1, State Consultation - License Amendment Request TMI-1 in Support of the ISFSI Only Security Plan License Amendment Request ML22068A1792022-03-0909 March 2022 Email from a Snyder to Acker State Consultation- License Amendment Request TMI-1 in Support of the ISFSI Only Emergency Plan and Emergency Action Level Scheme ML22068A1672022-03-0909 March 2022 Email from a Snyder to Acker State Consultation - License Amendment Request TMI-1 in Support of the ISFSI Only Security Plan License ML22068A1462022-03-0909 March 2022 Email from a Snyder to Acker Three Mile Island Unit 1, State Consultation- License Amendment Request TMI-1 in Support of the ISFSI Only Tech Spec License Amendment Request ML22090A0232022-03-0909 March 2022 Email from A. Snyder, NRC to Craig Smith, Constellation Energy Generation, License Amendment Request - Proposed ISFSI-Only Technical Specifications, Dated March 9, 2022 ML22047A2392022-02-16016 February 2022 E-mail from D. Kenney to A. Snyder Dated 2/16/2022 TMI Unit 1 Typo Correction to February 8, 2022 Submittal ML22038A9352022-02-0707 February 2022 TMI-2 Pdms LAR Email Dated 2/7/2022 from T. Smith, NRC to G. Van Noordennen ML22034A6702022-02-0303 February 2022 LTR-22-0020 Eric Epstein, E-mail Follow-up on Decommissioning and Tax Question from December 8, 2021 on TMI Cleanup Funding, Docket Id NRC-2021-0230 - Region I Response ML22343A1612021-11-0909 November 2021 Shpo Email 11-9-2021 Alowery to Gvannoordennen and Hpell ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21230A3812021-08-18018 August 2021 TMI-1 ISFSI-Only Security Plan License Amendment Request 2024-07-29
[Table view] |
Text
1 Whited, Jeffrey From: Whited, Jeffrey Sent: Tuesday, June 03, 2014 5:38 PM To: wendi.croft@exeloncorp.com Cc:Mascitelli, Francis J:(GenCo-Nuc) (Francis.Mascitelli@exeloncorp.com)
Subject:
THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - ACCEPTANCE OF REQUESTED LICENSING ACTION RE: ADOPTION OF TSTF-522 (TAC NO. MF4110)
SUBJECT:
THREE MILE ISLAND NUCLEAR STATION, UNIT 1 - ACCEPTANCE OF REQUESTED LICENSING ACTION RE: ADOPTION OF TSTF-522 (TAC NO. MF4110)
Dear Ms. Wendy Croft:
By letter dated May 7, 2014, (Agencywide Docu ment Access and Management System Accession No. ML14127A424) Exelon Generation Company, LLC submitted a license amendment request for Three Mile Island Nuclear Station Unit 1 (TMI-1). The proposed amendment would modify TMI-1 Technical Specification 4.12, Air Treatment System, by replacing an existing Surveillance Requirement to operate ventilation systems with charcoal filters for a 10-hour period every 31 days with a requirement to operate the systems for greater than or equal to 15 continuous minutes every 31 days in accordance with Technical Specification Task Force (TSTF) Traveler TSTF-522, Revision 0, "Revise Ventilation System Surveillance Requirements to Operate for 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> per Month."
The purpose of this e-mail is to provide the results of the U.S. Nuclear Regulatory Commission (NRC) staff's acceptance review of this license amendment request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.
The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Consistent with Section 50.90 of Title 10 of the Code of Federal Regulations (10 CFR), an amendment to the license (including the TS) must fully describe the changes requested, and following as far as applicable, the form prescribed for original applications. Section 50.34 of 10 CFR addresses the content of technical information required. This section stipulates that the submittal address the design and operating characteristics, unusual or novel design features, and principal safety considerations.
The NRC staff has reviewed your application and concluded that it does provide technical information in
sufficient detail to enable the NRC staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed license amendment request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. You will be advised of any further information needed to support the NRC staff's detailed technica l review by separate correspondence.
If you have any questions, please contact me at 301-415-4090.
JeffreyWhitedProjectManager BeaverValley,Susquehanna,andThreeMileIslandPlantLicensingBranchI 2DivisionofOperatingReactorLicensing 2 OfficeofNuclearReactorRegulationU.S.NuclearRegulatoryCommission(301)4154090jeffrey.whited@nrc.gov