TAC:56525
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Initiation
Questions Answers Results Other: ML20195C233, ML20209G130, ML20209G166, ML20209G183, ML20209G226, ML20209G235, ML20212H039, ML20236G894, ML20236G900, ML20236G904, ML20236N590 | |
| From | |
MONTHYEARML20195C2331986-05-21021 May 1986
[table view]Informs That Revised SPDS Design Will Be Submitted by 861231,per 860407 Ser.Design Currently Under Review to Remove Human Engineering Discrepancies within Sys & Change Displays ML20210G2431986-09-15015 September 1986 Forwards Audit Plan for Safety Evaluation of Facility Action Plan for Performance Improvement of Control Room Design & Spds.Audit Should Be Conducted in Early Oct to Preclude Impact on Proposed Restart Date ML20209G2261986-12-0505 December 1986 Rev 1 to Final Rept,Qualification Test of Isolation Device for SPDS Multiplexers Rancho Seco Nuclear Generating Station ML20209G2351986-12-30030 December 1986 Preliminary Results of Central Control Unit Isolation Devices Test,Rancho Seco Plant ML20209G1661986-12-31031 December 1986 SPDS Safety Analysis for Rancho Seco Nuclear Generating Station Unit 1 ML20209G1831986-12-31031 December 1986 Rev 1 to Availability Evaluation for SPDS at Rancho Seco Plant ML20209G1301987-01-12012 January 1987 Forwards Listed Documentation,Including 47-1139815-01, SPDS Safety Analysis for Rancho Seco Nuclear Generating Station Unit 1 & Rev 1 to BAW-1753, Availability Evaluation for Spds..., Per NRC Request Re ML20212H0391987-01-12012 January 1987 Responds to Questions Discussed During 861216 Telcon Re SPDS & Main Feedwater (MFW) Indication in Control Room.Util Will Revise Action Plan,Section 4B.19 Re MFW Pump Trips ML20212N3381987-01-14014 January 1987 Forwards Audit Plan for 870210-12 Safety Evaluation of SPDS in Lynchburg,Va ML20206S2681987-04-17017 April 1987 Forwards Description of SPDS Isolation Methodology Based on Discussion at 870407 Meeting.Method Will Provide Isolation When Exposed to Max Credible Fault.One Oversize Drawing Encl ML20236G8941987-07-24024 July 1987 Forwards Evaluations of Preliminary Test Results of SPDS Isolation Devices,Including Isolators 4,5,8,9 & 10 ML20236G9001987-07-24024 July 1987 Rev 0 to Test of Isolation Devices for Data Acquisition Sys (Anatec) ML20236G9041987-07-24024 July 1987 Rev 0 to Test of Ccu/Csu Interface Devices for Data Acquisition Sys (Anatec) ML20236N5901987-11-0909 November 1987 Discusses SPDS Safety Evaluation Issues Re Fire Protection, Software Validation & Verification & Electrical Isolation. Listing of Status of Each Issue & Comparison of Nonlinear Data Points in Final Acceptance Test Encl 1986-09-15 | |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:56525&oldid=4122645"