TAC:53166
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Questions Answers Results Other: ML20080G854, ML20086A840, ML20093G567, ML20113D694, ML20117L918, ML20138A294, ML20202C554 | |
From | |
MONTHYEARML20080G8541983-09-14014 September 1983
[table view]Advises That Actions Required by 830708 Generic Ltr 83-28, Items 2.2.2,4.2.3,4.2.4 & 4.3 Re Reactor Trip Breakers Currently Being Reviewed.Response Will Be Provided Upon Completion ML20086A8401983-11-0404 November 1983 Forwards Response to Generic Ltr 83-28, Required Actions Based on Generic Implications of Salem ATWS Events.' Proprietary List Rules Will Be Forwarded Separately ML20093G5671984-07-16016 July 1984 Forwards Responses to NRC Questions Re Preliminary Design for Automatic Shunt Trip Feature Per Generic Ltr 83-28.Shunt Trip Mod Will Be Installed During Fifth Refueling Outage ML20113D6941985-01-14014 January 1985 Forwards Response to Conditional Items Per 841108 SER on Generic Ltr 83-28,Item 4.3 Reactor Trip Breaker Automatic Shunt Trip. Addl Info Justifying Addition of Status Lights for Bypass Breakers Also Encl ML20113A5021985-01-14014 January 1985 Forwards Current List,As of 850111,for 58 Outstanding SER Issues.Specific Description of Unresolved Issue,Safety Evaluation for Issues Identified in Generic Ltr 82-33,SER, Safety Implementation Rept for SPDS & ACRS Items Requested ML20100B1091985-03-20020 March 1985 Forwards Addl Info Re Six Backfit Requirements,As Discussed in Util .Meetings Re Resolution of Items Requested.Agenda Should Include Major Points of NRC Basis (Improvement to Safety) ML20117L9181985-05-10010 May 1985 Forwards Revised Response to Generic Ltr 83-28,Item 4.3 Re Bypass Breaker Status Indication.Rev to Design Concept for Shunt Trip Attachment Automatic Actuation Includes Status Indication for Reactor Trip Bypass Breaker ML20135A7951985-09-0303 September 1985 Responds to 850816 Telcon Request for Addl Info on Generic Ltr 83-28,Item 4.3 Re Bypass Breaker Status Lights & Seismic Qualification of Shunt Trip Attachment.Diagram of Revised Design of Control Room Status Lights Encl ML20138K9041985-10-0909 October 1985 Forwards Supplemental Safety Evaluation Accepting 850114 & 0510 Responses to Generic Ltr 83-28,Item 4.3 on Proposed Design Mods for Automatic Shunt Trip.Tech Spec Changes Should Be Submitted ML20138A2941986-03-0404 March 1986 Advises That Shunt Trip Attachment & Automatic Shunt Trip Panel Seismically Qualified Per 840716 Commitment Re Generic Ltr 83-28,Item 4.3 & Listed Responses to 841108 Safety Evaluation.Qualification Based on Westinghouse Tests ML20202C5541986-04-0303 April 1986 Forwards Sser Accepting Util 860304 Response to Generic Ltr 83-28,Item 4.3, Seismic Qualification of Shunt Trip Components 1985-10-09 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:53166&oldid=3334315"