- 0CAN119104, Proposes Listed Changes in Communication Channels for performance-related Issues & Trends,Per 910924 Performance Meeting.Initial Objectives of Performance Meetings Satisfied & Further Performance Meetings Unnecessary +
- ELV-03206, Forwards Vogtle Unit 1,Cycle 4 Core Operating Limits Rept. Revised Rept Became Effective Upon Entry Into Mode 5 Following Completion of Fuel Loading +
- ELV-03200, Special Rept 1-91-5:on 911008,discovered That Amount of Grease Injected Into Vertical Tendon V10-102 Significantly Larger than Amount of Grease Removed from Tendon.Caused by Voids in Tendons.Tendon Retensioned +
- ELV-01006, Application for Amends to Licenses NPF-68 & NPF-81,changing Tech Specs 3/4.6.1.7 & 4.6.1.2f Re Containment Ventilation Sys to Clarify Action Statement & Surveillance Requirements Per NRC Info Notice 88-073 +
- ML20057B650 +
- 05000289/LER-1991-004-02, :on 911008,irradiated Fuel Assembly Moved W/O Verification of Containment Integrity During Performance of Main Fuel Bridge Hoist Test.Caused by Procedural Weaknesses/ Personnel Error.Incident Reviewed W/Personnel +
- 05000413/LER-1991-024, :on 911009,TS 3.0.3 Entered When Both Trains of Control Room Area Ventilation & Chilled Water Sys Declared Inoperable.Caused by Corroded Switch Contacts & Problems W/Actuator.Actuator to Be Replaced +
- ML20086D816 +
- ML20086C022 +
- ML20086D804 +
- ML20086B953 +
- 05000311/LER-1991-014-02, :on 911010,monitor 2R12B RMS Channel Failed Low Resulting in ESF Signal for CP/pressure-vacuum Relief Sys Isolation.Caused by Component Failure.Channel Returned to Svc.Mods Planned to Eliminate Spurious RMS +