Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000260/LER-1980-047-04, /04T-0:on 801107,component Cooling Water Pumps Found Not Operating,Thus Not Providing Adequate Dilution of Water to Environ.Caused by Component Cooling Water Pumps Being Out of Svc.Plant Instructions Revised + (09:04:52, 7 January 2025)
- 05000260/LER-1980-047, Forwards LER 80-047/04T-0 + (09:04:54, 7 January 2025)
- 05000260/LER-1980-045-01, /01T-0:on 801107,door Latch Mechanism Failed on Equipment Access Doors 237 & 238 Between Turbine Bldg & Reactor Bldg.Caused by Misaligned Latch Pin.Door Adjusted + (09:04:56, 7 January 2025)
- 05000260/LER-1980-045, Forwards LER 80-045/01T-0 + (09:04:57, 7 January 2025)
- ML18025B194 + (09:04:59, 7 January 2025)
- ML18025B190 + (09:05:00, 7 January 2025)
- ML18025B192 + (09:05:00, 7 January 2025)
- 05000260/LER-1980-044-03, /03L-0:on 801012,refueling Zone Inboard Isolation Time Delay Relay R3A Found Out of Tolerance & Nonrepetitive. Caused by Relay Failure.Relay,Agastat Model 7022 Ab,Replaced & Calibr + (09:05:02, 7 January 2025)
- 05000260/LER-1980-044, Forwards LER 80-044/03L-0 + (09:05:03, 7 January 2025)
- 05000260/LER-1980-043-03, /03L-0:on 801009,during Refueling operations,17 Level Switches Would Not Operate.Caused by Crud from Sys Accumulating on Float,Preventing Operation of Level Switch. Switches Cleaned,One Replaced + (09:05:11, 7 January 2025)
- 05000260/LER-1980-043, Forwards LER 80-043/03L-0 + (09:05:13, 7 January 2025)
- ML18025B183 + (09:05:14, 7 January 2025)
- ML18025B179 + (09:05:19, 7 January 2025)
- ML18025B174 + (09:05:20, 7 January 2025)
- ML18025B172 + (09:05:21, 7 January 2025)
- ML18025B171 + (09:05:23, 7 January 2025)
- ML18025B170 + (09:05:25, 7 January 2025)
- 05000260/LER-1980-042-03, LER:80-042/03L-0:on 800929,during Leak Rate Testing on Main Steam Isolation Valves,Valves 1-14,1-15,1-26 & 1-52 Exceeded Allowable Leakage Rate.Caused by Seating Surface Deterioration.Valves Repaired & Retested + (09:05:27, 7 January 2025)
- ML18025B168 + (09:05:31, 7 January 2025)
- 05000260/LER-1980-042, Forwards LER 80-042/03L-0 + (09:05:33, 7 January 2025)
- ML18025B165 + (09:05:35, 7 January 2025)
- ML18025B164 + (09:05:36, 7 January 2025)
- ML18025B162 + (09:05:37, 7 January 2025)
- ML18025B160 + (09:05:37, 7 January 2025)
- ML18025B158 + (09:05:41, 7 January 2025)
- ML18025B155 + (09:05:49, 7 January 2025)
- ML18025B154 + (09:05:51, 7 January 2025)
- 05000260/LER-1980-039-03, /03L-0:on 800916,drywell Control Air Valve 2-FCV-32-62 Could Not Be Closed by Handswitch.Cause Has Yet to Be Determined + (09:05:53, 7 January 2025)
- 05000260/LER-1980-039, Forwards LER 80-039/03L-0 + (09:05:57, 7 January 2025)
- 05000260/LER-1980-040-01, /01T-0:on 800929,five Main Steam Relief Valves Failed to Actuate within Required 1% of Set Pressure During Bench Test.Cause Unknown.Set Pressure Was Reset & Proper Operation Verified + (09:06:01, 7 January 2025)
- 05000260/LER-1980-040, Forwards LER 80-040/01T-0 + (09:06:04, 7 January 2025)
- PNO-II-80-119B, on 800628,76 of 185 Control Rods Failed to Fully Insert Due to Accumulation of Water in Scram Discharge Vol.Extensive Investigations & Tests Failed to Identify Cause of Accumulation of Water in Discharge Vol + (09:06:10, 7 January 2025)
- ML18025B138 + (09:06:11, 7 January 2025)
- ML18025B137 + (09:06:12, 7 January 2025)
- ML18025B134 + (09:06:13, 7 January 2025)
- ML18025B132 + (09:06:14, 7 January 2025)
- 05000260/LER-1980-003, Updated LER 80-03L/01X-1:on 800914,during EOC-3 Fuel Shuffling Operations,Fuel Assemblies Tz 758 & Tz 399 Discovered Misoriented 90 Degrees.Caused by Misorientation of 16 Fuel Assemblies During Previous Refueling Outage + (09:06:16, 7 January 2025)
- ML18025B129 + (09:06:18, 7 January 2025)
- 05000260/LER-1980-037, Forwards Updated LER 80-037/01X-1 + (09:06:19, 7 January 2025)
- ML18025B126 + (09:06:21, 7 January 2025)
- ML18025B124 + (09:06:25, 7 January 2025)
- ML18025B123 + (09:06:26, 7 January 2025)
- ML18025B122 + (09:06:27, 7 January 2025)
- ML18025B121 + (09:06:28, 7 January 2025)
- ML18025B119 + (09:06:30, 7 January 2025)
- ML18025B118 + (09:06:32, 7 January 2025)
- ML18025B117 + (09:06:33, 7 January 2025)
- 05000260/LER-1980-038-03, /03L-0:on 800911,during Refueling Outage W/Unit in Cold Shutdown,Hpci Check Valve 2-73-609 Failed Local Leak Rate Test.Caused by Buildup of Residual Matl on Body,Causing Disc of Hcpi Valve to Be Cocked Open.Matl Removed + (09:06:35, 7 January 2025)
- ML18025B113 + (09:06:37, 7 January 2025)
- 05000260/LER-1980-038, Forwards LER 80-038/03L-0 + (09:06:38, 7 January 2025)
- ML18025B110 + (09:06:42, 7 January 2025)