Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000289/LER-1986-011, :on 860601,breaker 1C-02 (Feeder Breaker to Turbine Plant Bus 1C) Tripped.Caused by Failure to Reset Plunger on Phase a Overload Device,Discovered on 860602. Westinghouse Breaker DB-25 Replaced + (04:13:05, 7 December 2024)
- ML20206U144 + (04:13:06, 7 December 2024)
- ML20206U143 + (04:13:07, 7 December 2024)
- ML20206U142 + (04:13:08, 7 December 2024)
- 05000352/LER-1986-028, :on 860603,ESF Actuated Control Room Emergency Fresh Air Sys.Caused by Ventilation Sys Toxic Gas Analyzer Misinterpreting Freon Refrigerant as Toxic Gas.Ventilation Manually Isolated + (04:13:09, 7 December 2024)
- 05000301/LER-1986-003, :on 860603,turbine Runback Occurred Due to Loss of Power on Instrument Bus.Caused by Trip of White Inverter Output Breaker.Procedures for Placing Inverter on Line Will Be Revised by 860901 + (04:13:11, 7 December 2024)
- ML20206U135 + (04:13:13, 7 December 2024)
- ML20206U137 + (04:13:13, 7 December 2024)
- 05000482/LER-1986-034, :on 860604,discovered That Handwheel Lock on Containment Isolation Valve Lf FV-96 Improperly Lockwired, Causing Valve to Be Inoperable.Caused by Personnel Error. Rept Incorporated Into Required Reading + (04:13:15, 7 December 2024)
- JPN-99-016, Forwards Application for Amend to License DPR-59,requesting 14 Day AOT for EDG Sys.Commitment Made by Util,Encl + (04:13:16, 7 December 2024)
- ML20206U125 + (04:13:17, 7 December 2024)
- ML20206U121 + (04:13:18, 7 December 2024)
- ML20206U123 + (04:13:18, 7 December 2024)
- ML20206U118 + (04:13:19, 7 December 2024)
- ML20206U117 + (04:13:20, 7 December 2024)
- RA99-093, Requests Extension of Time Periods for Submission of Annual Inventory Repts,As Required by Licensee Fundamental Nuclear Matl Plan & NUREG/BR-0007.NRC Forms 742C & 742 Will Be Submitted by 990604 & NRC Form 327 Submitted by 990702 + (04:13:21, 7 December 2024)
- ML20206U113 + (04:13:22, 7 December 2024)
- ML20206U105 + (04:13:23, 7 December 2024)
- ML20206U107 + (04:13:23, 7 December 2024)
- ML20206U104 + (04:13:24, 7 December 2024)
- B17764, Application for Amend to License NPF-49,deleting Reference to ASME Code Paragraph Iwv 3472(b) Re Frequency of Leakage Rate Testing for Valves Six Inches Nominal Pipe Size & Larger Contained in TS 4.4.6.2.2.e + (04:13:25, 7 December 2024)
- ML20206U100 + (04:13:25, 7 December 2024)
- ML20206U098 + (04:13:26, 7 December 2024)
- ML20206U092 + (04:13:27, 7 December 2024)
- ML20206U095 + (04:13:27, 7 December 2024)
- ML20206U088 + (04:13:28, 7 December 2024)
- B17783, Forwards NRC Forms 398 & 396 in Support of Licensee Renewal for Listed ROs & Sros.Attachments Contain Personal & Medical Info & No Redacted Versions Are Being Supplied.Encl Withheld Per 10CFR2.790(a)(6) + (04:13:29, 7 December 2024)
- ML20206U083 + (04:13:30, 7 December 2024)
- ML20206U084 + (04:13:30, 7 December 2024)
- ML20206U075 + (04:13:31, 7 December 2024)
- ML20206U072 + (04:13:32, 7 December 2024)
- ML20206U074 + (04:13:32, 7 December 2024)
- ML20206U069 + (04:13:33, 7 December 2024)
- AECM-86-0197, Application for Amend to License NPF-29,revising Tech Specs to Delete Control Room Chlorine Detectors & Requirement for Automatic Isolation of Control Room Upon Detection of Chlorine.Fee Paid + (04:13:34, 7 December 2024)
- ML20206U068 + (04:13:34, 7 December 2024)
- ML20206U065 + (04:13:35, 7 December 2024)
- ML20206U066 + (04:13:35, 7 December 2024)
- ML20206U063 + (04:13:36, 7 December 2024)
- ML20206U064 + (04:13:36, 7 December 2024)
- ML20206U062 + (04:13:37, 7 December 2024)
- ML20206U059 + (04:13:38, 7 December 2024)
- ML20206U060 + (04:13:38, 7 December 2024)
- ML20206U058 + (04:13:39, 7 December 2024)
- ML20206U054 + (04:13:39, 7 December 2024)
- ML20206U053 + (04:13:40, 7 December 2024)
- ML20206U050 + (04:13:41, 7 December 2024)
- ML20206U051 + (04:13:41, 7 December 2024)
- ML20206U047 + (04:13:42, 7 December 2024)
- ML20206U044 + (04:13:42, 7 December 2024)
- AECM-86-0192, Forwards Addl Info Re Util Evaluation of Structural Integrity of Unprotected Supports for Fire Barrier Assemblies Protecting Safe Shutdown Cable Raceways,Per Util 850614 Exception to 10CFR50,App R,Section III.G.2.a + (04:13:43, 7 December 2024)
- ML20206U039 + (04:13:44, 7 December 2024)