Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000325/LER-1979-044, Forwards LER 79-044/03L-0 + (18:47:10, 4 January 2025)
- ML19242A852 + (18:47:12, 4 January 2025)
- 05000333/LER-1979-043, Forwards LER 79-043/03L-0 + (18:47:14, 4 January 2025)
- 05000346/LER-1979-073-03, /03L-0 on 790708:during Checkout of Valve Relay, Main Steam Inlet to Auxiliary Feed Pipe Turbine 1-1 Isolation Valve Torqued While Opening.Caused by Normal Valve Wear.Valve Was Readjusted & Returned to Svc + (18:47:17, 4 January 2025)
- 05000346/LER-1979-073, Forwards LER 79-073/03L-0 + (18:47:19, 4 January 2025)
- ML19242A843 + (18:47:20, 4 January 2025)
- 05000366/LER-1979-067-03, /03L-0 on 790707:while Performing Sequence of HPCI Quick Start Test,Breaker for 2E41-F001 Valve Tripped. Caused by Motor Failure on Valve.Motor Was reworked,bench-tested, Reinstalled & Operated Satisfactorily + (18:47:24, 4 January 2025)
- 05000346/LER-1979-072-03, /03L-0 on 790708:position Indication on Rod Two of Group Eight Was Inoperable.Caused by Component Failure of Reed Switch within Position Indicator Tube.Part Was Replaced & Returned to Svc + (18:47:26, 4 January 2025)
- 05000333/LER-1979-044-03, /03L-0 on 790720:mainstream Line Tunnel Radiation Monitor D Drifted So That Indicator & Trip Point Were Approx 5.5% Low.Caused by Instrument Drift.Instrument Calibr & Tested + (18:47:29, 4 January 2025)
- 05000346/LER-1979-072, Forwards LER 79-072/03L-0 + (18:47:31, 4 January 2025)
- ML19242A836 + (18:47:33, 4 January 2025)
- 05000271/LER-1979-013-03, /03L-0 on 790710:during Testing of RHR Subsys Logic a Relay 10A-K46A Failed to Energize.Caused by Disconnected Lead of Contact to Relay Coils Control Circuit. Wire Was Reconnected & Sys Returned to Operation + (18:47:34, 4 January 2025)
- 05000366/LER-1979-067, Forwards LER 79-067/03L-0 + (18:47:36, 4 January 2025)
- 05000333/LER-1979-044, Forwards LER 79-044/03L-0 + (18:47:38, 4 January 2025)
- 05000271/LER-1979-013, Forwards LER 79-013/03L-0 + (18:47:40, 4 January 2025)
- 05000346/LER-1979-075-03, /03L-0 on 790708:no Visible Oil Level in Outboard Bearing Oil Reservoir Sight Glass on Containment Spray Pump 1-2.Caused by Component Failure.Oil Added to Reservoir & Fittings Tightened + (18:47:42, 4 January 2025)
- ML19242A827 + (18:47:43, 4 January 2025)
- 05000346/LER-1979-075, Forwards LER 79-075/03L-0 + (18:47:44, 4 January 2025)
- ML19242A823 + (18:47:46, 4 January 2025)
- ML19242A822 + (18:47:46, 4 January 2025)
- 05000324/LER-1979-021-03, /03L-0 on 790702:steam Line Snubber,Pump Suction Snubber & Main Steam Relief Smubbers Found Inoperable. Caused by Seal Failure.Snubbers Rebuilt,Functionally Tested & Reinstalled + (18:47:48, 4 January 2025)
- 05000366/LER-1979-069-03, /03L-0 on 790712:inboard Steam Isolation Valve (2E51-F001) Did Not Close When Isolation Signal Given. Caused by Valve Stem Being Galled Against Packing Follower. Stem Was Replaced + (18:47:50, 4 January 2025)
- ML19242A819 + (18:47:52, 4 January 2025)
- 05000324/LER-1979-021, Forwards LER 79-021/03L-0 + (18:47:53, 4 January 2025)
- ML19242A816 + (18:47:55, 4 January 2025)
- 05000366/LER-1979-069, Forwards LER 79-069/03L-0 + (18:47:56, 4 January 2025)
- ML19242A813 + (18:47:58, 4 January 2025)
- ML19242A812 + (18:48:03, 4 January 2025)
- ML19242A811 + (18:48:04, 4 January 2025)
- ML19242A810 + (18:48:06, 4 January 2025)
- ML19242A809 + (18:48:07, 4 January 2025)
- ML19242A808 + (18:48:07, 4 January 2025)
- ML19242A807 + (18:48:08, 4 January 2025)
- ML19242A806 + (18:48:10, 4 January 2025)
- ML19242A804 + (18:48:12, 4 January 2025)
- ML19242A805 + (18:48:12, 4 January 2025)
- ML19242A803 + (18:48:14, 4 January 2025)
- ML19242A802 + (18:48:15, 4 January 2025)
- ML19242A793 + (18:48:16, 4 January 2025)
- ML19242A788 + (18:48:16, 4 January 2025)
- ML19242A781 + (18:48:17, 4 January 2025)
- ML19242A785 + (18:48:17, 4 January 2025)
- ML19242A779 + (18:48:18, 4 January 2025)
- 05000219/LER-1979-023-01, /01T-0 on 790719:reactor Power Was Reduced Above Value for Removal of a Feedwater String.Caused by Removal of Recirculating Pump Reactor for Maint.Inboard & Outboard Collector Rings Resurfaced & Pump Returned to Svc + (18:48:20, 4 January 2025)
- 05000219/LER-1979-023, Forwards LER 79-023/01T-0 + (18:48:22, 4 January 2025)
- ML19242A772 + (18:48:23, 4 January 2025)
- ML19242A774 + (18:48:23, 4 January 2025)
- ML19242A771 + (18:48:24, 4 January 2025)
- ML19242A767 + (18:48:25, 4 January 2025)
- ML19242A768 + (18:48:25, 4 January 2025)
- ML19242A764 + (18:48:26, 4 January 2025)