Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19254F544 + (10:16:00, 4 January 2025)
- ML19254F543 + (10:16:02, 4 January 2025)
- ML19254F541 + (10:16:03, 4 January 2025)
- ML19254F540 + (10:16:08, 4 January 2025)
- ML19254F537 + (10:16:14, 4 January 2025)
- ML19254F536 + (10:16:15, 4 January 2025)
- ML19254F535 + (10:16:17, 4 January 2025)
- ML19254F534 + (10:16:19, 4 January 2025)
- ML19254F533 + (10:16:21, 4 January 2025)
- ML19254F531 + (10:16:23, 4 January 2025)
- ML19254F530 + (10:16:30, 4 January 2025)
- ML19254F529 + (10:16:32, 4 January 2025)
- IR 05000546/1979020 + (10:16:47, 4 January 2025)
- ML19254F527 + (10:16:50, 4 January 2025)
- ML19254F526 + (10:16:52, 4 January 2025)
- ML19254F524 + (10:16:54, 4 January 2025)
- ML19254F522 + (10:16:55, 4 January 2025)
- ML19254F521 + (10:16:57, 4 January 2025)
- ML19254F518 + (10:17:40, 4 January 2025)
- 05000366/LER-1979-114-03, /03L-0:on 791015,pump Suction from Suppression Chamber Valve 2E41-F041 Failed to Open When Initiated from Control Switch.Caused by Failure of Motor Winding.Direct Cause Not Known + (10:18:57, 4 January 2025)
- 05000366/LER-1979-114, Forwards LER 79-114/03L-0 + (10:20:38, 4 January 2025)
- ML19254F511 + (10:21:36, 4 January 2025)
- ML19254F510 + (10:21:39, 4 January 2025)
- ML19254F508 + (10:21:42, 4 January 2025)
- 05000302/LER-1979-098-99, /99T-0:on 791021,improper Mounting Discovered for Triaxial time-history Accelograph SI-2-MAT on Containment Ring Girder.Caused by Personnel Error.Technical Assistants Instructed in Proper Installation Techniques + (10:22:24, 4 January 2025)
- 05000302/LER-1979-098, Forwards LER 79-098/99T-0 + (10:23:09, 4 January 2025)
- ML19254F503 + (10:23:33, 4 January 2025)
- ML19254F502 + (10:23:38, 4 January 2025)
- ML19254F501 + (10:23:43, 4 January 2025)
- 05000334/LER-1979-041-03, /03L-0:on 791004,after Control Rod Bank D Was Withdrawn Several Steps,Analog Rod Position Indicators Demonstrated All Rods within +/- 5 Steps of Each Other. Caused by Instrument Drift.Indicators Recalibr + (10:24:28, 4 January 2025)
- ML19254F499 + (10:24:33, 4 January 2025)
- ML19254F498 + (10:24:35, 4 January 2025)
- 05000334/LER-1979-041, Forwards LER 79-041/03L-0 + (10:25:11, 4 January 2025)
- ML19254F495 + (10:25:17, 4 January 2025)
- 05000344/LER-1979-015-01, /01T-0:on 791019,discovered That Piping Restraint on Concrete Block Wall Might Result in Localized Overstress Condition & Degradation of Support Function Under Design Loads.Caused by Inadequate Consideration of Piping Design + (10:25:24, 4 January 2025)
- 05000333/LER-1979-083-03, /03L-0:on 791008,during Normal Operation,Routine Computer Printout of Core Performance Log Indicated That Max Fraction of Limiting Power Density Exceeded 1.000. Reactor Power Immediately Reduced 3% + (10:27:14, 4 January 2025)
- 05000333/LER-1979-083, Forwards LER 79-083/03L-0 + (10:27:40, 4 January 2025)
- ML19254F489 + (10:27:43, 4 January 2025)
- 05000338/LER-1979-139-03, /03L-0:on 791011,during Testing of RM-RMS-159, Power Fuses for Containment Particulate & Gas Radiation Monitors Blew.Caused by Short in Solenoid Valve K5.Solenoid Valve Coil Replaced & Monitors Returned to Svc + (10:28:25, 4 January 2025)
- 05000333/LER-1979-084-03, /03L-0:on 791009,during Surveillance Test F-ST-5Q, Average Power Range Monitor Channels a & D Tripped at Value Above Tech Spec Max.Caused by Error in Calibr Procedure. Calibr Procedure Revised & Instruments Returned to Svc + (10:28:56, 4 January 2025)
- 05000338/LER-1979-139, Forwards LER 79-139/03L-0 + (10:29:42, 4 January 2025)
- 05000237/LER-1979-033, Forwards LER 79-033/03X-1 + (10:30:09, 4 January 2025)
- 05000333/LER-1979-084, Forwards LER 79-084/03L-0 + (10:30:43, 4 January 2025)
- ML19254F479 + (10:30:47, 4 January 2025)
- ML19254F478 + (10:30:49, 4 January 2025)
- ML19254F477 + (10:30:51, 4 January 2025)
- 05000325/LER-1979-081-03, /03L-0:on 791005,during Normal Operation,Attempt to Start Reactor Bldg Exhaust & Supply Fan C Resulted in Tripping Breaker from Substation E-5 to Motor Control Ctr 1XG.Breaker Reset & Control Ctr re-energized + (10:31:31, 4 January 2025)
- ML19254F475 + (10:31:35, 4 January 2025)
- ML19254F474 + (10:31:37, 4 January 2025)
- 05000325/LER-1979-081, Forwards LER 79-081/03L-0 + (10:32:12, 4 January 2025)
- ML19254F471 + (10:32:17, 4 January 2025)