- ML19332B381 + (08:06:34, 31 December 2024)
- 05000309/LER-1980-017-03, /03L-0:on 800822,boron Sample Taken at Completion of Addition to RWST Indicated Concentration Below Tech Spec Limit.Caused by Failure of Technician to Obtain Sufficient Sample Prior to Addition + (08:06:36, 31 December 2024)
- 05000263/LER-1980-027-03, /03L-0:on 80823,during Monthly surveillance,42-11 Test Control Rod Could Not Be Withdrawn After Partial Insertion.Caused by Closed Drive Withdraw Riser Isolation Valve CRD-102.Valve Opened & Rod Was Operable + (08:06:38, 31 December 2024)
- ML19332B378 + (08:06:39, 31 December 2024)
- 05000324/LER-1980-066-01, /01T-0:on 800907,reactor Core Isolation Cooling Turbine Tripped on High Turbine Exhaust Pressure.Caused by Improper Valve Positioning Apparently Due to Personnel Error + (08:06:41, 31 December 2024)
- 05000309/LER-1980-017, Forwards LER 80-017/03L-0 + (08:06:43, 31 December 2024)
- 05000409/LER-1980-008-03, /03L-0: 800819,1B High Pressure Svc Water Diesel Did Not Start on Manual Activation.Diesel Did Start Locally from Battery Banks.Caused by Bad Cell in One B Bank Battery. Battery Replaced + (08:06:46, 31 December 2024)
- 05000409/LER-1980-008, Forwards LER 80-008/03L-0 + (08:06:52, 31 December 2024)
- 05000263/LER-1980-027, Forwards LER 80-027/03L-0 + (08:06:54, 31 December 2024)
- ML19332B367 + (08:06:57, 31 December 2024)
- ML19332B364 + (08:07:01, 31 December 2024)
- ML19332B363 + (08:07:02, 31 December 2024)
- ML19332B360 + (08:07:03, 31 December 2024)
- ML19332B359 + (08:07:04, 31 December 2024)
- ML19332B358 + (08:07:05, 31 December 2024)
- ML19332B356 + (08:07:06, 31 December 2024)
- ML19332B354 + (08:07:10, 31 December 2024)
- ML19332B353 + (08:07:11, 31 December 2024)
- ML19332B352 + (08:07:12, 31 December 2024)
- ML19332B351 + (08:07:13, 31 December 2024)
- ML19332B349 + (08:07:14, 31 December 2024)
- ML19332B350 + (08:07:14, 31 December 2024)
- ML19332B348 + (08:07:15, 31 December 2024)
- ML19332B347 + (08:07:16, 31 December 2024)
- ML19332B345 + (08:07:17, 31 December 2024)
- ML19332B344 + (08:07:18, 31 December 2024)
- ML19332B343 + (08:07:19, 31 December 2024)
- ML19332B342 + (08:07:20, 31 December 2024)
- ML19332B340 + (08:07:21, 31 December 2024)
- ML19332B338 + (08:07:22, 31 December 2024)
- ML19332B337 + (08:07:23, 31 December 2024)
- ML19332B336 + (08:07:24, 31 December 2024)
- ML19332B335 + (08:07:25, 31 December 2024)
- ML19332B334 + (08:07:26, 31 December 2024)
- ML19332B333 + (08:07:27, 31 December 2024)
- ML19332B332 + (08:07:28, 31 December 2024)
- ML19332B331 + (08:07:29, 31 December 2024)
- ML19332B330 + (08:07:29, 31 December 2024)
- ML19332B326 + (08:07:32, 31 December 2024)
- 05000309/LER-1980-018-03, /03L-0:on 800826,during Steady State Power Operation,W/Diesel generator,DG-1B,being Operated in Surveillance mode,DG-1B Auto Tripped on Overspeed.Caused by Loose Overspeed Trip Switch Actuating Arm.Arm Tightened + (08:07:34, 31 December 2024)
- ML19332B324 + (08:07:35, 31 December 2024)
- 05000309/LER-1980-018, Forwards LER 80-018/03L-0 + (08:07:37, 31 December 2024)
- ML19332B320 + (08:07:38, 31 December 2024)
- ML19332B319 + (08:07:39, 31 December 2024)
- ML19332B318 + (08:07:39, 31 December 2024)
- 05000293/LER-1980-032-01, /01T:on 800724,GE SIL 299 Review Revealed Higher Drywell Ambient Temp than Used for Original Safeguard Yarway Calibrs.Caused by High Temp Due to Inadequate Drywell Cooling.Recalibr & Survey of Drywell Ventilation Conducted + (08:07:41, 31 December 2024)
- ML19332B315 + (08:07:42, 31 December 2024)
- 05000293/LER-1980-032, Forwards LER 80-032/01T-0 + (08:07:43, 31 December 2024)
- ML19332B309 + (08:07:44, 31 December 2024)
- 05000312/LER-1980-040-03, /03L-0:on 800812,reactor Protection Sys Channel D Trip Signal Was Received.Caused by Amplifier Failure in Electronic Portion of Transmitter.Transmitter Replaced, Calibr,Leak Tested & Returned to Svc + (08:07:46, 31 December 2024)
- 05000293/LER-1980-050-01, /01T-0:on 800911,during Mgt Review,Concluded That Operation & Maint on Containment Cooling Sys Had Been Conducted in Less Conservative Manner than Prescribed in Tech Specs.Caused by Sparse & Ambiguous Tech Specs + (08:07:48, 31 December 2024)