Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000368/LER-1978-031-03, /03L-0 on 781207:failure to Perform Semiannual Surveillance on Triaxial response-spectrum Recorders 2XR-8350 as Scheduled on 781005.Caused by Personnel Error + (11:10:27, 3 January 2025)
- 05000313/LER-1978-031, Forwards LER 78-031/03L-0 + (11:10:29, 3 January 2025)
- ML19270F551 + (11:10:30, 3 January 2025)
- ML19270F549 + (11:10:31, 3 January 2025)
- 05000321/LER-1979-006-03, /03L-0 on 790122:during Normal Startup,Reactor Operated Above 1% for Over 24-h W/O Critical Mass Peaking Factor Being Calculated.Caused by Computer Limitations for Low Power Operation + (11:10:32, 3 January 2025)
- 05000321/LER-1979-006, Forwards LER 79-006/03L-0 + (11:10:34, 3 January 2025)
- 05000321/LER-1979-022-03, /03L-0 on 790120:during Normal Operation & Procedure HNP-1-3405,core Isolation Cooling Min Flow Valve (E51-F006) Failed to Close Automatically at 80 Gpm.Caused by Failure of Open Limit Switch + (11:10:36, 3 January 2025)
- 05000321/LER-1979-022, Forwards LER 79-022/03L-0 + (11:10:38, 3 January 2025)
- 05000321/LER-1979-009-03, /03L-0 on 790123:during Normal Operation,While Performing Maint on Reactor Water Cleanup Pumps,Personnel Unable to Sample Primary Coolant Every 4-h.Caused by Stopped Up Redundant Sample Line + (11:10:39, 3 January 2025)
- ML19270F541 + (11:10:41, 3 January 2025)
- 05000321/LER-1979-009, Forwards LER 79-009/03L-0 + (11:10:42, 3 January 2025)
- 05000338/LER-1979-006-03, /03L-0 on 790111:damaged Wiper Seal Found on Hydraulic Suppressor 1-FW-HSS-233.Caused by Poppet Valves Which Control Lock Up Rate Being Improperly Set.Suppressor Replaced W/Operable Spare Suppressor.No Danger to Public + (11:10:47, 3 January 2025)
- 05000338/LER-1979-006, Forwards LER 79-006/03L-0 + (11:10:50, 3 January 2025)
- 05000321/LER-1979-014-03, /03L-0 on 790124:secondary Containment Violation Surveillance Not Performed Immediately After Restoration of Secondary Containment,Due to Misinterpretation of Tech Specs.Memo Subsequently Issued to Clarify Requirements + (11:10:52, 3 January 2025)
- 05000346/LER-1979-011-03, /03L-0:on 790115,reactor Coolant Pump 1-2-2 Started W/Incorrect Breaker Alignment,Causing Low Voltage Relays to Trip Which de-energized Both 4.16 Kv Essential Buses C1 & D1.Caused by Personnel Error + (11:10:54, 3 January 2025)
- ML19270F533 + (11:10:56, 3 January 2025)
- 05000321/LER-1979-014, Forwards LER 79-014/03L-0 + (11:10:57, 3 January 2025)
- 05000366/LER-1979-010-03, /03L-0 on 790117:in Cold Shutdown,While Performing HNP-2-3820,switches 2B21-N301 F,H & L Did Not Actuate.Caused by Switch Diaphragm Failure + (11:10:59, 3 January 2025)
- 05000346/LER-1979-011, Forwards LER 79-011/03L-0 + (11:11:01, 3 January 2025)
- 05000346/LER-1979-009-03, /03L-0:on 790112,power to Vital Bus Y2 Lost. False Integrated Control Sys Signal Resulted in Reactor & Full Steam & Feedwater Rupture Control Sys Trip.Caused by Blown 125 Volt DC Fuse to Inverter + (11:11:02, 3 January 2025)
- ML19270F526 + (11:11:04, 3 January 2025)
- 05000366/LER-1979-010, Forwards LER 79-010/03L-0 + (11:11:05, 3 January 2025)
- 05000346/LER-1979-009, Forwards LER 79-009/03L-0 + (11:11:07, 3 January 2025)
- ML19270F520 + (11:11:08, 3 January 2025)
- 05000338/LER-1979-008-01, /01T-0 on 790129:design Flow of 37 Gpm to Charging Pump Coolers Could Not Be Met.Caused by 2 Inch Carbon Steel Piping & Charging Pump Skid Piping Being Too Large to Allow Adequate Flow + (11:11:09, 3 January 2025)
- 05000338/LER-1979-005-01, /01T-0 on 790129:mufflers for Emergency Diesel Generators Not Seismically Supported Nor Missile Protected as Required by Fsar.Caused by Const Error + (11:11:11, 3 January 2025)
- 05000338/LER-1979-005, Forwards LER 79-005/01T-0 & 79-008/01T-0 + (11:11:12, 3 January 2025)
- ML19270F515 + (11:11:14, 3 January 2025)
- ML19270F514 + (11:11:15, 3 January 2025)
- PM-79-116, Updates Re 790124 Scram.Informs of Satisfactory Leak Rate Test of Valve E11-F015A & Insp Results of Torus Spray Header,Piping & Hangers.No Significant Damage Found + (11:11:23, 3 January 2025)
- ML19270F508 + (11:11:26, 3 January 2025)
- ML19270F507 + (11:11:27, 3 January 2025)
- ML19270F503 + (11:11:28, 3 January 2025)
- ML19270F499 + (11:11:29, 3 January 2025)
- ML19270F498 + (11:11:30, 3 January 2025)
- ML19270F496 + (11:11:32, 3 January 2025)
- ML19270F495 + (11:11:33, 3 January 2025)
- ML19270F492 + (11:11:34, 3 January 2025)
- ML19270F491 + (11:11:35, 3 January 2025)
- ML19270F490 + (11:11:36, 3 January 2025)
- ML19270F489 + (11:11:37, 3 January 2025)
- ML19270F488 + (11:11:38, 3 January 2025)
- ML19270F487 + (11:11:39, 3 January 2025)
- ML19270F483 + (11:11:40, 3 January 2025)
- ML19270F484 + (11:11:40, 3 January 2025)
- 05000324/LER-1979-005-03, /03L-0 on 790109:RHR Pump Discharge Pressure Switch E11-PS-N020D Failed,Causing Pump Running Annunciator. Caused by Contact Plunger Stem Corrosion + (11:11:42, 3 January 2025)
- ML19270F480 + (11:11:43, 3 January 2025)
- 05000324/LER-1979-005, Forwards LER 79-005/03L-0 + (11:11:45, 3 January 2025)
- ML19270F477 + (11:11:46, 3 January 2025)
- ML19270F475 + (11:11:47, 3 January 2025)