Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19270H075 + (10:52:20, 3 January 2025)
- ML19270H074 + (10:52:21, 3 January 2025)
- ML19270H073 + (10:52:22, 3 January 2025)
- ML19270H072 + (10:52:23, 3 January 2025)
- ML19270H071 + (10:52:24, 3 January 2025)
- ML19270H070 + (10:52:25, 3 January 2025)
- ML19270H068 + (10:52:26, 3 January 2025)
- ML19270H069 + (10:52:26, 3 January 2025)
- ML19270H067 + (10:52:27, 3 January 2025)
- ML19270H066 + (10:52:28, 3 January 2025)
- ML19270H064 + (10:52:29, 3 January 2025)
- 05000304/LER-1978-079-03, /03X-1 on 780901:valve 2FCV-PR24A Did Not Remain Open After Containment Isolation Test,Causing Particulate & Gas Monitors to Be Inoperable.Caused by Misaligned Limit Switch.Switch Adjusted + (10:52:30, 3 January 2025)
- ML19270H062 + (10:52:32, 3 January 2025)
- ML19270H061 + (10:52:33, 3 January 2025)
- ML19270H060 + (10:52:33, 3 January 2025)
- ML19270H059 + (10:52:34, 3 January 2025)
- ML19270H057 + (10:52:35, 3 January 2025)
- ML19270H056 + (10:52:36, 3 January 2025)
- ML19270H055 + (10:52:37, 3 January 2025)
- ML19270H053 + (10:52:38, 3 January 2025)
- ML19270H052 + (10:52:38, 3 January 2025)
- 05000324/LER-1979-037-03, /03L-0 on 790519:control Panel Instrument 2-CAC-ATH-1263-2 Gave Downscale Reading & 2-CAC-ATH-1259-2 Was Out of Calibr.Caused by Being Out of Calibr.Both Instruments Recalibr & Returned to Svc + (10:52:40, 3 January 2025)
- ML19270H050 + (10:52:42, 3 January 2025)
- 05000324/LER-1979-037, Forwards LER 79-037/03L-0 + (10:52:43, 3 January 2025)
- 05000324/LER-1979-038-03, /03L-0 on 790521:when Diesel Generator 3 Speed Was Lowered to 60 Hertz Per Second,Engine Failed to Start Alarm Energized,Making Generator Inoperable.Caused by Upward Drift in Airpox Tachometer Switches.Switches Recalibr + (10:52:50, 3 January 2025)
- 05000324/LER-1979-038, Forwards LER 79-038/03L-0 + (10:52:52, 3 January 2025)
- 05000304/LER-1977-010-03, /03L-0 on 770327:reactor Tripped & Breaker Train a Failed to Open.Breaker Taken to Shop & Tested.No Cause Found.Breaker Reinstalled & Verified Operable + (10:52:56, 3 January 2025)
- 05000324/LER-1979-039-03, /03L-0 on 790519:leak Rate Test on Airlock Not Completed within 72-h.Caused by Administrative Oversight. Test Completed Satisfactorily + (10:52:58, 3 January 2025)
- 05000304/LER-1977-010, Forwards LER 77-010/03L-0 + (10:53:00, 3 January 2025)
- 05000324/LER-1979-039, Forwards LER 79-039/03L-0 + (10:53:02, 3 January 2025)
- 05000304/LER-1979-032-03, /03L-0 on 790508:after Reactor Trip,Train a Reactor Trip Breaker Failed to Open.Caused by Plunger Out of Adjustment in Undervoltage Coil + (10:53:10, 3 January 2025)
- 05000304/LER-1979-032, Forwards LER 79-032/03L-0 + (10:53:12, 3 January 2025)
- 05000346/LER-1979-061-03, /03L-0 on 790518:control Room Emergency Damper HV5311A Stuck in Open Position During Surveillance Testing. Caused by Humidity Corroding Brass Bushings of Shaft.Damper Repaired & Humidifiers Relocated + (10:53:14, 3 January 2025)
- 05000265/LER-1979-010-03, /03L-0 on 790514:2A Fuel Pool Radiation Monitor Failed Upscale & Failed Again on 790601 & 02.Caused by Failure of GM-tube in Sensor Conventor Unit.Tube Finally Replaced W/Amperex 18529 + (10:53:16, 3 January 2025)
- 05000346/LER-1979-061, Forwards LER 79-061/03L-0 + (10:53:17, 3 January 2025)
- 05000265/LER-1979-010, Forwards LER 79-010/03L-0 + (10:53:19, 3 January 2025)
- ML19270H024 + (10:53:20, 3 January 2025)
- ML19270H023 + (10:53:21, 3 January 2025)
- ML19270H021 + (10:53:21, 3 January 2025)
- 05000324/LER-1979-035-03, /03L-0 on 790521:during Startup from Refueling Outage,Disccovered That Mod to Rod Lock Monitor Was Neither Approved Nor Installed.Mod Approved & Installed.Procedures Being Written to Prevent Recurrence + (10:53:22, 3 January 2025)
- 05000237/LER-1979-039-03, /03L-0 on 790528:125 Volt Dc Switch 2,reserve Feed Bus 22, Was Opened Causing Trip of 282 Recirculation Motor Generator Set Oil Pump.Caused by Inadvertent Opening of Switch.Switch Marked to Caution Against Opening + (10:53:24, 3 January 2025)
- ML19270H017 + (10:53:25, 3 January 2025)
- 05000324/LER-1979-035, Forwards LER 79-035/03L-0 + (10:53:26, 3 January 2025)
- ML19270H014 + (10:53:27, 3 January 2025)
- ML19270H013 + (10:53:28, 3 January 2025)
- ML19270H012 + (10:53:28, 3 January 2025)
- 05000265/LER-1979-009, Forwards LER 79-009/03L-0.Corrects Docket Number of Original Forwarding Ltr + (10:53:30, 3 January 2025)
- ML19270H010 + (10:53:32, 3 January 2025)
- 05000304/LER-1978-079, Forwards LER 78-079/03X-1.Update Notes Rept Number Change from 78-077 to 78-079 + (10:53:33, 3 January 2025)
- ML19270H006 + (10:53:34, 3 January 2025)
- ML19270H004 + (10:53:35, 3 January 2025)