- 05000313/LER-1979-005, Forwards LER 79-005/03L-0 + (10:18:36, 3 January 2025)
- ML19273B965 + (10:18:39, 3 January 2025)
- ML19273B963 + (10:18:43, 3 January 2025)
- ML19273B962 + (10:18:44, 3 January 2025)
- ML19273B961 + (10:18:45, 3 January 2025)
- ML19273B958 + (10:18:50, 3 January 2025)
- ML19273B957 + (10:18:51, 3 January 2025)
- ML19273B955 + (10:18:53, 3 January 2025)
- 05000333/LER-1979-030-03, /03L-0 on 790518:during Cold Shutdown,Test Point Was Discovered in Error.Caused by Deviations in Conduction of Surveillance Test Procedures F-ISP-89.Procedure Was Immediately Correted & Surveillance Complete + (10:18:54, 3 January 2025)
- ML19273B953 + (10:18:56, 3 January 2025)
- 05000368/LER-1979-036-03, /03L-0 on 790514:during Mode 3,emergency Feedwater Supply Valve Did Not Meet Required Limiting Value of Stroke Time.Caused by Tripper Bar Pickup Out of Adjustment & Low Oil Level.Repairs Made + (10:18:58, 3 January 2025)
- 05000333/LER-1979-030, Forwards LER 79-030/03L-0 + (10:19:00, 3 January 2025)
- ML19273B948 + (10:19:02, 3 January 2025)
- ML19273B947 + (10:19:09, 3 January 2025)
- 05000368/LER-1979-035-03, /03L-0 on 790514:during Mode 3,emergency Feedwater Flow Control Valve Failed to Open or Respond to Demand Signal.Similar to LERs 50-368/78-028 & 50-368/78-009. Caused by Pressure Switch Malfunction.Switch Repaired + (10:19:11, 3 January 2025)
- 05000333/LER-1979-028-03, /03L-0 on 790517:during Cold Shutdown,Level Instrument of Carbon Dioxide Storage Sys Was Out of Calibr. Caused by Procedural Error.Instrument Racalibr & Satisfactorily Tested + (10:19:13, 3 January 2025)
- ML19273B944 + (10:19:15, 3 January 2025)
- 05000333/LER-1979-028, Forwards LER 79-028/03L-0 + (10:19:16, 3 January 2025)
- 05000312/LER-1979-005-03, /03L-0 on 790509:two Inaccessible Safety Sys Hydraulic Snubbers Were Inoperable.Cause Unknown.One Snubber Rebuilt & Tested;Other Snubber Refilled + (10:19:19, 3 January 2025)
- ML19273B939 + (10:19:20, 3 January 2025)
- 05000312/LER-1979-005, Forwards LER 79-005/03L-0 + (10:19:22, 3 January 2025)
- 05000346/LER-1979-059-03, /03L-0 on 790517:unsealed Hole Discovered in Fire Barrier Floor.Caused by Uncompleted Survey of Work Items.Gap Sealed & Training Meeting Held W/Maint & Const Supervisors + (10:19:24, 3 January 2025)
- 05000346/LER-1979-059, Forwards LER 79-059/03L-0 + (10:19:26, 3 January 2025)
- 05000346/LER-1979-060-03, /03L-0 on 790519:fire Barrier Removed to Allow Removal of Hydraulic Snubber,But Continuous Fire Watch Was Not Established.Caused by Faulty Procedure.Mod Made to Hydraulic Snubber Testing Procedure + (10:19:32, 3 January 2025)
- 05000346/LER-1979-060, Forwards LER 79-060/03L-0 + (10:19:33, 3 January 2025)
- 05000338/LER-1979-054-03, /03L-0 on 790513:charging Pump Removed from Svc to Repair Crack Inlet Piping.Caused by Bad Weld at Base of Vent Line.Crack Ground Out & Rewelded + (10:19:36, 3 January 2025)
- 05000338/LER-1979-054, Forwards LER 79-054/03L-0 + (10:19:38, 3 January 2025)
- ML19273B926 + (10:19:39, 3 January 2025)
- ML19273B927 + (10:19:39, 3 January 2025)
- ML19273B925 + (10:19:41, 3 January 2025)
- ML19273B924 + (10:19:42, 3 January 2025)
- ML19273B922 + (10:19:43, 3 January 2025)
- 05000324/LER-1979-033-03, /03L-0 on 790518:HPCI Turbine Tripped on Mechanical Overspeed at 3,500 Rpm.Caused by Spring Adjusting Screw Being Approx Five Turns Out of Position.Set Screw for Securing Spring Adjusting Screw Was Approx Six Turns Out + (10:19:44, 3 January 2025)
- 05000324/LER-1979-033, Forwards LER 79-033/03L-0 + (10:19:46, 3 January 2025)
- 05000302/LER-1979-052-03, /03L-0 on 790516:in Mode 6,diesel Driver Fire Svc Pumps Discovered to Be Out of Svc.Caused by Diesel Manufacturer Representative Being Unfamiliar W/Approved Plant Procedures.Personnel Instructed + (10:19:48, 3 January 2025)
- 05000302/LER-1979-052, Forwards LER 79-052/03L-0 + (10:19:50, 3 January 2025)
- 05000336/LER-1978-019-03, /03X-2 on 780803:while Operating 13U Diesel for Surveillance,Leaking Injector Pump Observed.Caused by Elemental Lead Inclusions,Resulting in Stress Risers at Surface of Valve Cages + (10:19:52, 3 January 2025)
- ML19273B914 + (10:19:53, 3 January 2025)
- 05000336/LER-1978-019, Forwards LER 78-019/03X-2 + (10:20:02, 3 January 2025)
- ML19273B911 + (10:20:03, 3 January 2025)
- ML19273B908 + (10:20:04, 3 January 2025)
- ML19273B907 + (10:20:05, 3 January 2025)
- ML19273B906 + (10:20:07, 3 January 2025)
- ML19273B904 + (10:20:08, 3 January 2025)
- ML19273B903 + (10:20:09, 3 January 2025)
- ML19273B901 + (10:20:10, 3 January 2025)
- 05000333/LER-1979-032-03, /03L-0 on 790519:sequencing Timer Associated W/Total Flooding Carbon Dioxide Sys Not Functioning Properly.Cause Not Stated.Sequencing Timer Cams Adjusted + (10:20:12, 3 January 2025)
- ML19273B898 + (10:20:14, 3 January 2025)
- ML19273B897 + (10:20:15, 3 January 2025)
- ML19273B896 + (10:20:17, 3 January 2025)
- 05000333/LER-1979-032, Forwards LER 79-032/03L-0 + (10:20:18, 3 January 2025)