- 05000368/LER-1979-079-03, /03L-0:on 790904,containment Bldg Sump Level Indicator Was Inoperable.Caused by Loss of Power Due to Power Supply Being Inadvertently Switched Off.Power Supply Was re-energized within 13-h & Caution Cord Attached + (08:34:22, 3 January 2025)
- 05000368/LER-1979-078-03, /03L-0:on 790828,refueling Water Tank Level Indicator Read 2.7% Less than Computer Point Indication. Caused by Current Loop Opening When Indicator Head Was Lifted.Resistor Location Corrected & Indicator Recalibr + (08:34:27, 3 January 2025)
- 05000338/LER-1979-107-03, /03L-0:on 790831,slug of Water Entered Process Vent Blower & Filter B Causing Vent Flow to Decrease to Zero & Blower to Stop.Caused by Water Entering from Spent Resin Dewatering Tank Vent.Water Drained & Filters Replaced + (08:34:32, 3 January 2025)
- ML19275A283 + (08:34:36, 3 January 2025)
- ML19275A282 + (08:34:37, 3 January 2025)
- 05000338/LER-1979-107, Forwards LER 79-107/03L-0 + (08:35:12, 3 January 2025)
- ML19275A278 + (08:35:16, 3 January 2025)
- 05000338/LER-1979-120-01, /01T-0:on 790917,potential for Failure of Certain Control Sys When Subjected to Adverse Environ Discussed W/ Westinghouse.Review of FSAR Indicated That Present Analysis Will Remain Unaffected + (08:35:49, 3 January 2025)
- ML19275A276 + (08:35:52, 3 January 2025)
- ML19275A275 + (08:35:53, 3 January 2025)
- 05000245/LER-1979-026-01, /01T-0:on 790914,discovered That Loss of Power to ECCS Electrical Buses Could Occur W/O Being Sensed by Loss of Normal Power Initiation Logic.Caused by Design Oversight. Logic Changed + (08:35:56, 3 January 2025)
- 05000318/LER-1979-034-01, /01T-0:on 790914,noted That Air Start Sys Hangers Not Built to Meet Seismic Requirements.Caused by Error Classifying Lines as Nonseismic.Installation of Seismic Pipe Supports Upgraded Diesel Starting Air Sys + (08:36:09, 3 January 2025)
- ML19275A272 + (08:36:13, 3 January 2025)
- 05000245/LER-1979-026, Forwards LER 79-026/01T-0 + (08:36:16, 3 January 2025)
- ML19275A269 + (08:36:22, 3 January 2025)
- 05000338/LER-1979-120, Forwards LER 79-120/01T-0 + (08:36:39, 3 January 2025)
- 05000318/LER-1979-034, Forwards LER 79-034/01T-0 + (08:37:01, 3 January 2025)
- ML19275A264 + (08:37:05, 3 January 2025)
- ML19275A262 + (08:37:06, 3 January 2025)
- ML19275A261 + (08:37:08, 3 January 2025)
- ML19275A257 + (08:37:09, 3 January 2025)
- ML19275A256 + (08:37:10, 3 January 2025)
- ML19275A255 + (08:37:11, 3 January 2025)
- ML19275A254 + (08:37:12, 3 January 2025)
- ML19275A253 + (08:37:15, 3 January 2025)
- ML19275A252 + (08:37:17, 3 January 2025)
- ML19275A251 + (08:37:18, 3 January 2025)
- 05000336/LER-1979-026-03, /03L-0:on 790906,fluctuation Noted in Indicated Level of Safety Injection Tank 3 W/No Concurrent Plant Evaluation or Change in Tank Pressure.Cause Not Determined. Calibr Checked & Transmitter Replaced + (08:37:47, 3 January 2025)
- 05000336/LER-1979-026, Forwards LER 79-026/03L-0 + (08:38:13, 3 January 2025)
- ML19275A247 + (08:38:15, 3 January 2025)
- ML19275A246 + (08:38:17, 3 January 2025)
- 05000219/LER-1979-031-03, /03L-0:on 790829,seal Water Piping Found Cracked on Short Pipe Nipple Section Where Threaded Into Seal Cartridge.Caused by Operator Using half-inch Piping as Foot Support.Pipe Nipple Replaced + (08:38:48, 3 January 2025)
- ML19275A244 + (08:38:52, 3 January 2025)
- ML19275A243 + (08:38:54, 3 January 2025)
- ML19275A242 + (08:38:55, 3 January 2025)
- ML19275A241 + (08:38:57, 3 January 2025)
- ML19275A240 + (08:38:58, 3 January 2025)
- 05000219/LER-1979-031, Forwards LER 79-031/03L-0 + (08:39:20, 3 January 2025)
- ML19275A236 + (08:39:22, 3 January 2025)
- ML19275A234 + (08:39:23, 3 January 2025)
- ML19275A233 + (08:39:30, 3 January 2025)
- ML19275A232 + (08:39:31, 3 January 2025)
- 05000338/LER-1979-105-03, /03L-0:on 790828,during Testing of Containment Particulate Monitor,Power Fuses Blew When Sample Pump Was Placed in Stop Position Causing Particulate & Gas Monitor to Be Inoperable.Caused by Shorted Valve K5 + (08:40:10, 3 January 2025)
- ML19275A230 + (08:40:23, 3 January 2025)
- ML19275A229 + (08:40:25, 3 January 2025)
- IR 05000460/1979008 + (08:40:28, 3 January 2025)
- 05000338/LER-1979-100-03, /03L-0:on 790903,during Steady State Operation, Greater than 12-step Disagreement Was Noted Between Rod Position Indicator D-10 & Group Demand Indication.Caused by Voltage Drift in Signal Conditioning Card + (08:40:42, 3 January 2025)
- ML19275A226 + (08:40:45, 3 January 2025)
- ML19275A224 + (08:40:47, 3 January 2025)
- ML19275A223 + (08:40:49, 3 January 2025)
- ML19275A221 + (08:40:50, 3 January 2025)