- 05000324/LER-1982-048, Forwards Updated LER 82-048/03L-1 + (03:29:52, 27 May 2025)
- 05000325/LER-1982-062, Forwards LER 82-062/03L-0 + (03:30:02, 27 May 2025)
- 05000334/LER-1981-006-03, During Surveillance Tests on Low Head Safety Injection Pumps,Water in Recirculation Line on Refueling Water Storage Tank Found Frozen.Caused by Heat Trace Circuit Thermostat Line in Off Position + (03:30:04, 27 May 2025)
- 05000334/LER-1982-020-03, /03L-0:on 820610,chlorine Detector CLA-VS-101B, Found to Have Slow Trip Rate.Caused by Dirty Wick.Wick Checked & Cleaned.Procedure Revised to Replace Demineralized Water W/Distilled Water + (03:30:06, 27 May 2025)
- 05000280/LER-1982-035-03, /03L-0:on 820607,w/unit at Full power,TV-IA-201A Would Not Remain Closed After High Radiation Test Signal Cleared.Caused by Incomplete Valve Contact Due to Loosened Limit Switch Mounting Plate.Plate Secured + (03:30:09, 27 May 2025)
- 05000334/LER-1981-006, Forwards Updated LER 81-006/03X-1.Detailed Event Analysis Encl + (03:30:11, 27 May 2025)
- 05000325/LER-1982-061-03, /03L-0:on 820607,source Range Monitor C Indicated Count of 3.0 X 10(4) While Monitors a & D Indicated 1.5 X 10(3).Caused by Failure of Monitor C Input Signal Preamplifier.Preamplifier Replaced + (03:30:14, 27 May 2025)
- 05000260/LER-1982-018-03, /03L-0:on 820602,while Calibr Pressure Switches That Bypass Control Valve Fast Closure/Stop Valve Scram, Pressure Switch PS-1-81B Operated at 156.9 Psig.Caused by Instrument Drift.Switch Recalibr & Tested + (03:30:16, 27 May 2025)
- 05000280/LER-1982-061-03, /03L-0:on 820606,w/unit at 100% Power,Core Cooling Monitor a Showed Erratic Indication & Was Removed from Svc. Caused by Failed Printed Circuit Board.Board Replaced + (03:30:17, 27 May 2025)
- 05000338/LER-1982-046-03, /03L-0:on 820603,control Room Door Seal Failed, Decreasing Emergency Ventilation & Bottled Air Pressurization Sys Ability to Pressurize Control Room. Seal Failure Due to Normal Wear.Seal Replaced + (03:30:29, 27 May 2025)
- 05000321/LER-1982-052-03, /03L-0:on 820601,determined That Four Fire Doors Did Not Comply W/Tech Specs.On 820605 Two Unit 2 Doors Failed to Comply W/Tech Specs.Caused by Component Failure. Unit 1 Doors Repaired.Unit 2 Doors Replaced + (03:30:45, 27 May 2025)
- 05000325/LER-1982-056, Forwards LER 82-056/03L-0 + (03:30:53, 27 May 2025)
- 05000369/LER-1982-040-03, /03L-0:on 820529,during Fire Protection Sys High Velocity Flush & Chlorination Periodic Test,Five Fire Hose Stations in Auxiliary Bldg Discovered W/O Adequate Water Pressure.Caused by Mistaken Valve Lineup in Test + (03:31:01, 27 May 2025)
- 05000327/LER-1982-068-03, /03L-0:on 820603,condenser Vacuum Exhaust Radiation Monitor 1-RM-90-119 Had Spurious High Radiation Signals.Caused by Noise Picked Up by Monitor Detector Signal Cable.Detector Cables Will Be Installed in Conduit + (03:31:04, 27 May 2025)
- 05000287/LER-1982-008-01, /01T-0:on 820609,during Removal of Locking Clips on Thermal Shield bolts,19 of 27 Bolts Had Bolt Heads Broken Off.Upon Completion of Locking Clip removal,46 of 96 Had Heads Broken Off.Caused by Stress Cracking + (03:31:13, 27 May 2025)
- TAC:44478 + (03:31:16, 27 May 2025)
- 05000269/LER-1982-007-01, /01T-0:on 820616,during Periodic Environ Surveillance,Keowee Hydro Station Water Fire Suppression Sys Declared Inoperable Due to Inability to Obtain Flow from Fire Hydrant.Caused by Clogged Inlet Strainer + (03:31:23, 27 May 2025)
- 05000271/LER-1981-030, Updated LER 81-030/03L-1:cracks Found on Internal Surface of Valve Bodies & Seating Surfaces of Reactor Water Cleanup Valves Attributed to Surface Shrinking of Casting & Intergranular Stress Corrosion Cracking,Respectively + (03:31:29, 27 May 2025)
- IR 05000333/1980020 + (03:31:44, 27 May 2025)
- 05000259/LER-1982-037-03, /03L-0:on 820528,pressure Switches 1-PS-1-8A & B Found Operating Out of Calibr.Caused by Calibr Drift.Switch 1-PS-18B Recalibr.Switch 1-PS-18A Replaced + (03:31:47, 27 May 2025)
- 05000259/LER-1982-038-03, /03L-0:on 820601,pressure Switches PS-3-74B Switch 1 & 2 Found Operating Out of Calibr.Caused by Calibr Drift. Switches Recalibr,Returned to Svc & Replaced 820622 + (03:31:55, 27 May 2025)
- IR 05000327/1981028 + (03:31:58, 27 May 2025)
- 05000311/LER-1981-050, Forwards LER 81-050/03X-1.Detailed Event Analysis Encl + (03:33:08, 27 May 2025)
- 05000272/LER-1982-039-03, /03L-0:on 820608,three Valves Found Missing from Surveillance Procedure Action Statement 3.6.1.1.Caused by Oversight.Immediate Change Incorporated Into Procedure + (03:33:11, 27 May 2025)
- 05000275/LER-1982-007-03, /03L-0:on 820526,prior to Fuel Load,Control Room Received Alarm on Plant Vent Iodine Sampler (RE-24).Caused by Failure of Sample Pump Due to End of Vane Life.Pump Cleaned,Vanes Replaced & Oil Changed + (03:33:12, 27 May 2025)
- 05000311/LER-1982-048-03, /03L-0:on 820606,red Tag Discovered Missing from post-LOCA Sampling Sys Containment Isolation Valve.Tagging Request Form Also Missing.Tag Inadvertently Knocked Off & Tagging Request Form Lost.Form Reissued & Tag Replaced + (03:33:17, 27 May 2025)
- 05000280/LER-1982-032-03, /03L-0:on 820531,pressure in Nitrogen Bottle Supplying Emergency Air to PCV-MS-202A & B Found Below Tech Spec Limit.Caused by Fitting Leaks in Air Lines.Fittings Tightened & Pressurized Bottle Installed + (03:33:28, 27 May 2025)
- ML20054L619 + (03:33:35, 27 May 2025)
- ML20054L603 + (03:33:40, 27 May 2025)
- IR 05000213/1981014 + (03:33:40, 27 May 2025)
- AECM-82-300, Application for Amend to License NPF-13 Proposing Change to License Condition 2.C(42) & Tech Spec 3/4.6.5,drywell post-LOCA Vacuum Breakers + (03:33:43, 27 May 2025)
- 05000272/LER-1982-038-03, /03L-0:on 820604,pressurizer Pressure Discovered Less than Tech Spec Requirements.Caused by Shift of Pressure Controller from Auto to Manual Mode W/O Operator Action. Incident Termed Isolated Controller Malfunction + (03:34:00, 27 May 2025)
- 05000361/LER-1982-015-03, /03L-0:on 820512,diesel Generator 2G003 Tripped During Monthly Surveillance Test.Caused by Failed Resistor within Power Supply Module,Cutting Power to Governor Control Module.Power Supply Module Replaced + (03:34:38, 27 May 2025)
- 05000361/LER-1982-020-01, /01T-0:on 820608,containment Air Lock Operability Test Not Performed in Time Required by Tech Spec.Caused by Personnel Error.Personnel Reinstructed + (03:34:43, 27 May 2025)
- TAC:48414 + (03:35:21, 27 May 2025)
- ML20054L352 + (03:35:29, 27 May 2025)
- IR 05000410/1982002 + (03:35:45, 27 May 2025)
- 05000346/LER-1982-026-03, /03L-0:on 820530 & 0608,fire Door 504 Between Computer Room & Cabinet Room Found Blocked Open.Caused by Personnel Error.Personnel Instructed in Proper Procedure for Blocking fire/safety-related Doors + (03:36:23, 27 May 2025)
- 05000373/LER-1982-036-03, /03L-0:on 820606,during Performance of STP-17 Hot Line Walks,Mechanical Snubber MS14-1058S Found Damaged. Snap Ring Which Holds Snubber Together Had Become Loose. Caused by Introduction of Lateral Force on Snubber + (03:36:26, 27 May 2025)
- IR 05000412/1982004 + (03:36:31, 27 May 2025)
- IR 05000315/1982007 + (03:36:32, 27 May 2025)
- IR 05000333/1982008 + (03:36:34, 27 May 2025)
- 05000373/LER-1982-034-03, /03L-0:on 820605,RHR Shutdown Cooling Isolation Valve 1E12-F009 Would Not Open Due to Isolated RHR Pump Suction Flow Switch 1E31-N012B.Caused by Flow Switch Left Isolated During Personnel Reassignment + (03:36:50, 27 May 2025)
- 05000293/LER-1982-016-03, /03L-0:on 820602,weekly Average Power Range Monitor Surveillance Test Not Performed for Wk Ending 820527.Caused by Verbal Miscommunication During Development Phase.Training on Master Surveillance Program Completed + (03:37:01, 27 May 2025)
- 05000336/LER-1982-018-03, /03L-0:on 820527,containment Atmosphere Particulate Radioactivity Monitoring Channels Became Inoperable When Indication Went Offscale High.Caused by Valve Leakage.Detector Shielding Added + (03:37:03, 27 May 2025)
- 05000313/LER-1982-012-03, /03L-0:on 820525,steam Generator a Tube Leak Determined from Indications on Condenser Offgas & N-16 Monitors.Leakage Undetectable Using Normal Leak Rate Calculations.Caused by Intergranular Cracking + (03:37:15, 27 May 2025)
- 05000289/LER-1982-009-03, /03L-0:on 820526,during Shutdown,Improper Valve Lineup Discovered.Caused by Technician Failure to Follow Sampling Procedure & to Realign Valves + (03:37:20, 27 May 2025)
- 05000219/LER-1982-032-03, /03L-0:on 820524,during Reactor Shutdown,B Main Steam Line Tunnel Rod Monitors Output Failed Downscale. Caused by Drift of Grid Bias on front-end Amplifier.Drawer Replaced W/Operational Spare + (03:37:24, 27 May 2025)
- ML20054L050 + (03:37:26, 27 May 2025)
- 05000298/LER-1982-013-03, /03L-0:on 820607,during Performance of Snubber Operability Test,Two Mechanical Shock Suppressors, RR-SNUB-SS7A1 & RR-SNUB-SS7B1,found Inoperable.Caused by Overload of Snubbers.Snubbers Replaced + (03:37:41, 27 May 2025)
- 05000336/LER-1982-019, Forwards LER 82-019/99X-0.Detailed Event Analysis Encl + (03:37:46, 27 May 2025)