Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000366/LER-1981-102, Forwards Updated LER 81-102/03X-1 + (15:12:32, 26 May 2025)
- 05000321/LER-1980-023-03, Hpic Did Not Actuate Until Tech Spec Limit Passed.Caused by Instrument Drift. Switches Calibr & Necessary Design Changes Will Be Implemented + (15:12:35, 26 May 2025)
- 05000321/LER-1980-023, Forwards Updated LER 80-023/03X-1 + (15:12:38, 26 May 2025)
- 05000321/LER-1981-090-01, Performance of RCIC Turbine Exhaust Diaphragm Pressure Instrument Showed N012 A-D Switches Actuating Above Tech Spec.Caused by Setpoint Drift.Switches Recalibr.Design Changes Implemented + (15:12:42, 26 May 2025)
- 05000321/LER-1981-090, Forwards Updated LER 81-090/01X-1 + (15:12:44, 26 May 2025)
- 05000321/LER-1980-013-03, Reactor Recirculation Pump a Tripped Causing Power Reduction.Caused by Electrical Short Circuit Due to Steam Leak in Drywell.Terminal Board Replaced & Tested + (15:12:48, 26 May 2025)
- 05000321/LER-1980-013, Forwards Updated LER 80-013/03X-1 + (15:12:51, 26 May 2025)
- ML20070K460 + (15:13:28, 26 May 2025)
- ML20070K390 + (15:13:34, 26 May 2025)
- 05000321/LER-1980-058-03, During steady-state Operation,Control Rod Drive Units Could Not Maintain Required Pressure.Caused by Cartridge Valve 1C11-F111 Leaking at Steam Packing.Valves Rebuilt + (15:13:45, 26 May 2025)
- 05000321/LER-1980-058, Forwards Updated LER 80-058/03X-1 + (15:13:48, 26 May 2025)
- ML20070K311 + (15:13:52, 26 May 2025)
- ML20070K304 + (15:13:55, 26 May 2025)
- ML20070J790 + (15:15:04, 26 May 2025)
- ML20070J582 + (15:15:34, 26 May 2025)
- ML20070J290 + (15:15:56, 26 May 2025)
- ML20070H811 + (15:16:32, 26 May 2025)
- ML20070H209 + (15:17:30, 26 May 2025)
- ML20070G911 + (15:17:54, 26 May 2025)
- 05000338/LER-1982-079-03, /03L-0:on 821126,in Mode 3,flow Path from Boric Acid Tanks to RCS Inoperable.Caused by Ruptured Diaphragm of Boric Acid Transfer Pump Suction Header Isolation Valve 1-CH-80.Valve Diaphragm Replaced + (15:18:18, 26 May 2025)
- 05000338/LER-1982-079, Forwards LER 82-079/03L-0 + (15:18:28, 26 May 2025)
- ML20070G538 + (15:18:44, 26 May 2025)
- ML20070G478 + (15:18:55, 26 May 2025)
- 05000272/LER-1982-091-01, /01T-0:on 821130,leakage Discovered from Weld on Svc Water Piping to Component Cooling HX 12.Caused by Degradation of Weld & Similar Joints Due to Type of Filler Metal Used & Corrosive Environ of Svc Water Sys + (15:18:59, 26 May 2025)
- 05000338/LER-1982-078-03, /03L-0:on 821125,in Mode 3,120-volt Ac Vital Bus 1-IV Lost Voltage.Caused by Failure of Normal Power Supply Inverter 1-VB-I-04 Due to Failed Oscillator Board, Transformer & Fuse.Parts Replaced & Inverter Tested + (15:19:08, 26 May 2025)
- 05000338/LER-1982-078, Forwards LER 82-078/03L-0 + (15:19:12, 26 May 2025)
- 05000333/LER-1982-051-03, While Conducting Surveillance Testing on Reactor Low Water Scram Switch 02-3-LIS-101D,setpoint Found Less Conservative than Required.Caused by Instrument Drift.Setpoint Adjusted + (15:19:37, 26 May 2025)
- 05000387/LER-1982-005, Forwards LER 82-05L/03L-0 + (15:19:49, 26 May 2025)
- TAC:46275 + (15:20:12, 26 May 2025)
- 05000361/LER-1991-001-01, :on 910125,post-accident Cleanup Unit Inlet Duct Heater Found in Off Position,Resulting in Deenergization of Heater.From 910119-22,operability of Heater Pilot Switch Not Satisfied + (15:20:51, 26 May 2025)
- ML20070F294 + (15:21:26, 26 May 2025)
- ELV-02543, Forwards Reply to Notice of Violation & Proposed Imposition of Civil Penalty Re Unsecured,Unprotected & Unattended Safeguards Info Per Insp Repts 50-424/90-27 & 50-425/90-27 + (15:21:36, 26 May 2025)
- 05000335/LER-1982-053-03, /03L-0:on 821108,while Performing post-maint Surveillance Test of 1C Steam Driven Auxiliary Feedwater Pump,Steam Supply Valve from 1A Steam Generator Failed to Open.Caused by Failure of Contact in Switch + (15:22:03, 26 May 2025)
- 05000335/LER-1982-053, Forwards LER 82-053/03L-0 + (15:22:09, 26 May 2025)
- 05000333/LER-1990-005, :on 900220,high Pressure Coolant Injection Sys Inoperable.Caused by Binding in Remote Servo Resulting in Delay in Valve Response.Remote Servo Mechanism Replaced & Maint Insp Will Be Conducted + (15:22:19, 26 May 2025)
- 05000254/LER-1991-005, :on 910131,Train B of Standby Gas Treatment Sys Unexpectedly Autostarted,Resulting in Deenergization of Primary Containment Isolation Group II Relay Logic.Caused by Inadequate Procedure.Relay Logic Reset + (15:22:27, 26 May 2025)
- TAC:56447 + (15:23:06, 26 May 2025)
- 05000249/LER-1982-046-03, /03L-0:on 821112,water Discovered Spraying from 1-inch Drain Line Off Bottom of Feedwater Regulator Isolation Valve 3A.Caused by Cracked Weld at 1-inch Chain Line Due to Stresses from Thermal Effects + (15:23:24, 26 May 2025)
- 05000416/LER-1982-122, Forwards LER 82-122/99X-0 + (15:23:26, 26 May 2025)
- 05000249/LER-1982-046, Forwards LER 82-046/03L-0 + (15:23:29, 26 May 2025)
- 05000321/LER-1980-003-03, While Performing RHR Valve Operability Procedure,Outboard Shutdown Cooling Isolation Valve F008 Opened in 25.8-S.Caused by Normal Wear & Human Reaction Time.Valve Operator Adjusted + (15:23:37, 26 May 2025)
- 05000321/LER-1980-003, Forwards Revised LER 80-003/03X-1 + (15:23:44, 26 May 2025)
- ML20070E157 + (15:24:07, 26 May 2025)
- ML20070D905 + (15:24:34, 26 May 2025)
- TAC:48510 + (15:24:43, 26 May 2025)
- ML20070D829 + (15:24:48, 26 May 2025)
- TAC:M83431 + (15:24:57, 26 May 2025)
- 05000334/LER-1982-052-03, /03L-0:on 821105,leaking Fire Hydrant Reported in Southeast Yard.Cause Not Stated.Leak Isolated & Temporary Fire Hose Installed in Fuel Bldg to Insure Adequate Fire Protection + (15:25:31, 26 May 2025)
- 05000334/LER-1982-052, Forwards LER 82-052/03L-0 + (15:25:36, 26 May 2025)
- ML20070D379 + (15:25:49, 26 May 2025)
- 05000321/LER-1980-059-03, 2-h After Performance of Suppression Chamber to Drywell Vacuum Breaker Sys Operability Procedure,Closed Indication F Vacuum Breaker Light Found Extinguished.Caused by Burned Out Lamp + (15:25:53, 26 May 2025)