Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20072R858 + (13:36:55, 26 May 2025)
- ML20072R844 + (13:36:56, 26 May 2025)
- ML20072R840 + (13:36:59, 26 May 2025)
- ML20072R794 + (13:37:03, 26 May 2025)
- ML20072R785 + (13:37:05, 26 May 2025)
- ML20072R780 + (13:37:07, 26 May 2025)
- ML20072R772 + (13:37:09, 26 May 2025)
- ASLBP 20-962-01-LA-BD01, NRC Staff Answer Opposing Epstein Motion + (13:37:13, 26 May 2025)
- 05000454/LER-1994-008-06, :on 940803,discovered That Since 940304,CS Valves Not Stroke Time Tested in Closed Direction Due to Misinterpretation of TS Requirements.Ist Review That Added Valves Verified as Complete + (13:37:28, 26 May 2025)
- ML20072R474 + (13:37:41, 26 May 2025)
- ML20072R463 + (13:37:44, 26 May 2025)
- ML20072R449 + (13:37:46, 26 May 2025)
- ML20072R381 + (13:37:58, 26 May 2025)
- ML20072R348 + (13:38:00, 26 May 2025)
- NRC-94-4268, Forwards Proprietary LTCT-T2R-023,LTCT-T2R-025 & LTCT-T2R-032,providing NRC W/Info on AP600 Matrix Tests of Sufficient Depth to Enable Early Evaluation & Analysis of Test Results.Repts Withheld (Ref 10CFR2.790) + (13:38:02, 26 May 2025)
- ML20072R330 + (13:38:05, 26 May 2025)
- ML20072R328 + (13:38:07, 26 May 2025)
- ML20072R325 + (13:38:09, 26 May 2025)
- 05000424/LER-1994-005-03, :on 940810,follow-up Investigation Found That Failed Relay Inside of Radiation Monitor Had Caused CVI Signal.Caused by Failure of 1RE-2565 Output Relay.Failed Relay Was Replaced + (13:38:10, 26 May 2025)
- ML20072R322 + (13:38:12, 26 May 2025)
- 05000338/LER-1983-010-03, /03L-0:on 830304,while in Mod 3,fire Door S71-17 Between 1J Emergency Diesel Generator Room & Turbine Bldg Declared Inoperable.Caused by Warping Due to Closing Door During Diesel Operation.Closure Device Readjusted + (13:38:13, 26 May 2025)
- ML20072R317 + (13:38:15, 26 May 2025)
- ML20072R305 + (13:38:17, 26 May 2025)
- 05000339/LER-1983-020-03, /03L-0:on 830302,MOV-RS-55A,2-RS-P-2A Suction Isolation Valve Could Not Be Reopened After Having Been Closed for Periodic Test,Rendering Recirculation Spray Pump Inoperable.Caused by Stripped Bevel Gear.Gear Replaced + (13:38:19, 26 May 2025)
- 05000336/LER-1980-012-03, During Power Operation, Hydraulic Snubber on Hangar 490001 Found W/No Visible Fluid Level.Caused by Seal Deterioration.Snubber Replaced + (13:38:21, 26 May 2025)
- 05000353/LER-1994-007-01, :on 940328,identified That Weekly Performance of I&C ST Procedure ST-2-074-424-2 Had Not Been Performed by Due Date.Caused by Less than Adequate Communications. Procedures Has Been Revised & Staff Counseled + (13:38:25, 26 May 2025)
- 05000321/LER-1983-024-03, /03L-0:on 830224,A Hydrogen Peroxide Analyzers Found Out of Calibr During Hydrogen & Oxygen Analyzer Instrument Surveillance Procedure.Caused by Instrument Drift.Analyzers Recalibr.Design Change Request Written + (13:38:26, 26 May 2025)
- 05000336/LER-1980-012, Forwards Updated LER 80-012/03X-1 + (13:38:27, 26 May 2025)
- ML20072R247 + (13:38:31, 26 May 2025)
- ML20072R159 + (13:38:44, 26 May 2025)
- ML20072R153 + (13:38:46, 26 May 2025)
- 05000366/LER-1980-162-03, While Reviewing Local Leak Rate Test Data on Vent Purge Outlet Isolation Valve 2T48-F318,leakage Determined to Exceed Allowable Tech Spec Limits.Caused by Worn Seat Rings.Rings Replaced + (13:38:48, 26 May 2025)
- 05000336/LER-1981-011-03, Accessible safety-related Intl Nuclear Safeguards Co Mechanical Snubbers Stroke Tested Per IE Bulletin 81-01.Fifteen Snubbers Failed to Stroke.Caused by Generic Problems.Snubbers Replaced + (13:38:51, 26 May 2025)
- 05000366/LER-1980-162, Forwards Updated LER 80-162/03X-1 + (13:38:54, 26 May 2025)
- 05000336/LER-1981-011, Forwards Updated LER 81-011/03X-1 + (13:38:57, 26 May 2025)
- 05000321/LER-1982-095-03, While Shut Down for Refueling/Torus Mod Outage,Various Containment Isolation Valves Did Not Have Acceptable Results During Local Leak Rate Testing.Valves Repaired to Meet Tech Specs + (13:39:00, 26 May 2025)
- 05000321/LER-1982-095, Forwards Updated LER 82-095/03X-1 + (13:39:03, 26 May 2025)
- 05000395/LER-1983-019-01, /01L-0:on 830317,trains of RHR & High Head Safety Injection Train a Inoperable for Approx 45 Minutes.Caused by Switching Problems W/Starting Circuitry of Chiller Unit XHX0001C.Switch Apparatus Modified + (13:39:06, 26 May 2025)
- 05000458/LER-1994-007, :on 940501,RPS Bus B Lost Due to Electrical Protection Assembly (EPA) Breakers Failure.Epa Breakers Will Be Modified by Replacing Existing Logic Cards W/New Generation III Logic Cards + (13:39:15, 26 May 2025)
- ML20072Q984 + (13:39:17, 26 May 2025)
- 05000483/LER-1994-004, :on 940816,found That Surveillance of Tech Spec on Total Curie Content in Gdt E Not Properly Performed Due to Cognitive Human Performance Error.Responsible Technicians Counseled on Failure to Follow Procedure + (13:39:19, 26 May 2025)
- 05000366/LER-1980-021-03, During Local Leak Rate Test While Shut Down,Various Containment Isolation Valves Did Not Have Acceptable Initial Test Results.Caused by Improper Adjustments.Each Valve Repaired & Retested + (13:39:22, 26 May 2025)
- 05000424/LER-1991-003-03, :on 910222,during Relay Testing RHR Sys Containment Sump Suction Valve Opened.Caused by Electrical Ground on stem-mounted Limit Switch.Ground Condition Will Be Examined,Confirmed & Corrected + (13:39:25, 26 May 2025)
- 05000336/LER-1981-018-03, Mechanical Snubber Discovered Omitted from IE Bulletin 81-01 Evaluation List. No Cause Stated.Snubbers Reviewed & Reclassified as safety-related.Thirty-nine Snubbers Failed Stroke Test + (13:39:27, 26 May 2025)
- 05000366/LER-1980-021, Forwards Updated LER 80-021/03X-1 + (13:39:28, 26 May 2025)
- ML20072Q945 + (13:39:30, 26 May 2025)
- ML20072Q923 + (13:39:37, 26 May 2025)
- 05000321/LER-1991-005-02, :on 910217,pressure Spike Experienced on Instrument Sensing Line While Attempting to Rectify Mismatch Between Redundant Reactor Water Level Indications.Caused by Air Bubble in Sensing Line.Sys Restored to Svc + (13:39:39, 26 May 2025)
- 05000413/LER-1991-007, :on 910115,Tech Spec Violation Re Failure to Perform Reactor Trip Sys Surveillance Due to Inappropriate Action.Discussion of Event & Action W/Personnel Involved, Training to Improve Communications + (13:39:41, 26 May 2025)
- 05000336/LER-1981-018, Forwards Updated LER 81-018/03X-2 + (13:39:43, 26 May 2025)
- ML20072Q913 + (13:39:45, 26 May 2025)