[k UNITED STATES j l X(., j NUCLEAR REGULATORY COMMISSION t

WA$HINGTON, D.C. 20555 0001 o

5

%J p

        • +

NORTHEAST NUCLEAR ENERGY COMPANY. ET AL.

QDCKET N0. 50-423 MILLSTONE NUCLEAR POWER STATION. UNIT NO. 3 AMENDMENT TO FACILITY OPERATING LICEf151 Amendment No. 94 License No. NPF-49 1.

The Nuclear Regulatory Commission (the Commission) has found that:

l A.

The application for amendment by Northeast Nuclear Energy Company, et al. (the licensee), dated May 27, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and t v 3ssion's rules and regulations set forth in 10 CFR Chapter i, B.

The facility will operate conformity with the application, the provisions of the Act, and se rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

94o9130194 940901 PDR ADOCK 05000423 P

PDR

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-49 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised l

through Amendment No. 94

, and the Environmental Protection Plan

~

contained in Appendix B, both of which are attached hereto are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

j 3.

This license amendment is effective as of the date of its issuance, to be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION i

John F. S olz, Director Project Directorate I-4 Division of Reactor Projects - 1/II i

Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

September 1, 1994 i

ATTACHMENT TO LICENSE AMENDMENT NO. 94 FACIllTY OPERATING LICENSE NO. NPF-49 DOCKET N0. 50-423 Replace the following page of the Appendix A Technical Specifications with the l

enclosed page.

The revised page is identified by amendment number and contains vertical lines indicating the areas of change.

Remove Insert 6-5 6-5 l

1 i

i i

I i

l l

ADMINISTRATIVE CONTROLS 6.3 FACILITY STAFF OVALIFICATIONS 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971* for comparable positions, except for the i

Health Physics Manager who shall meet or exceed the qualifications of Regulatory Guide 1.8, Revision 1, May 1977.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Senior Vice President -

Millstone Station and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and 10 CFR Part 55.59. The Director-Nuclear Training has the overall responsibility for the implementation of the Training Program.

6.4.2 Deleted.

6.5 REVIEW AND AUDIT 6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)

FUNCTION 6.5.1.1 The PORC shall function to advise the Nuclear Unit Director on all matters related to nuclear safety.

COMPOSITION l

l 6.5.1.2 The PORC shall be composed of the:

l Chairperson:

Nuclear Unit Director l

Vice Chairperson and Member:

Operations Manager l

Member:

Maintenance Manager Member:

Instrument and Controls Manager Member:

Reactor Engineer Member:

Radiation Protection Supervisor or l

Chemistry Supervisor Member:

Engineering Manager j

l Member:

Staff Engineer l

l

  • For the period ending three years after the issuance of Amendment No.

, the Operations Manager will be permitted to have held a senior reactor operator license at a similar Pressurized Water Reactor other than Millstone Unit No. 3 and at least one of the Operations Assistant (s) shall hold a senior reactor operator license.

I MILLSTONE - UNIT 3 6-5 Amendment No. 77, 77, pp. 77, 94 0287 i

!