Amend 138 to License DPR-46,revising TS Table 3.7.4 to Reflect Mod Associated W/Air Operated Testable Check Valves RCIC-AO-22 & HPCI-AO-18
ML20072R317
Person / Time
Site: Cooper 
Issue date: 03/15/1991
From: Quay T
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20072R320 List:
References
NUDOCS 9103250083
Download: ML20072R317 (4)


Text

_ _. - _ _

i e eare.q\\

e UNiitDSTATES

[

NUCLEAR RECULATORY COMMISSION 5

wamatow, c. c. seems g

i e...+

.4 A

NEBRASKA PUBLIC POWER DISTRICT DOCKET NO. 50-298 COOPER NUCLEAR STATION AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.138 License No. DPR-46 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Nebraska Public Power District (the licensee) dated January ll, 1990, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized-

[

by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commir.sion's regulations; D.

The issuance'of this license amendment will not be inimical to the common defense and security or to the health and safety of the pubile; and

)

t E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

~ 9103250083 910315 PDR ADOCK 05000298.

p PDR r

z.

o

)

.p.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of facility Operating License No. OPR 46 is hereby amended to read as follows:

2.

lechnicalSpecifications The Tecnnical Specifications contained in Appendix A, as revised through Amendment N' o.138, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

The license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION n

8 t t v d c %. h d y

-)

ac j

Theodore R. Quay, Direct.or Project Directorate IV-1 Division of Reactor Projects III, IV, and V Office of Nuclear Reactor Regulation Attachtnent:

Changes to the Technical Specifications Date of Issuance: March 15,1991 p

s

,.v-

,n nw.-

..,,.w,.~.

a

,.-~ ~....,,, - -, -.

-,,,.,,,,--,-n--n--

r, n. r-y v,,--,

,1-.,..,n.w e-.,,

k ATTACHMENT TO LICENSE AMENDMENT NO.138 FACILITY OPERATING LICENSE NO. DPR-46 DOCKET NO. 50-298 Replace the following page of the Appendix A Technical Specifications with the enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the area of change, REMOVE PAGE INSERT PAGE 173 173 i

l l

l

TABLE 3.7,4 e

PRIMARY CONTAINMENT TESTABLE ISOLATION VALVES TEST PEN. NO.

VALVE RUMBERS HEDIA X.7A MS. A0 80A and MS. A0 86A, Main Steam Isolation Valves Air MS.A0 80B and MS.AO.86B, Main Steam Isolation Valves Air X 7B X.7C MS.A0 80C and MS A0 86C, Main Steam Isolation Valves Air X 7D MS*A0 800 and MS.A0 86D, Main Steam Isolation valves Air X.8 MS MO.74 and MS MO.77, Main Steam Line Drain Air X 9A RT 15CV and RF.16CV, Feedvater Check Valves Air X 9A RCIC.26CV, and RWCU.15CV, RCIC/RVCU Connection Air to Feedwater X 9B RP.13CV and RF 14CV, Feedwater Check Valves Air Air X 9B HPCI.29CV, HPCI Cotinection to feedwater Air X 10 RCIC.MO.15 and RCIC.MO.16, RCIC Stea., Line X.11 HPCI.MO 15 and HPCI.MO 16, HPCI Steam Line Air X 12 RRR.MO.17 and RHR.MO 16, RHR Suction Cooling Air X 13A RHR.MO 25A and P.HR.MO.27A, RHR Supply to RPV Air X 13B RHR.MO 25B and RRR.MO 27B, RHR Supply to RTV Air X 14 RWCU MO 15 and RWCU.MO 18 Inlet to RWCU System Air X.16A CS.MO*11A and CS.MO 12A, Core Spray to RPV Air X 16B CS.MO 11B and CS.MO 12B, Core Spray to RPV Air X.18 RW.732Av' and RW.733AV, Drywell Equipment Sump Discharge Air f

X.19 RV.765AV and RW.766AV, Drywell Floor Drain Sump Discharge Air f

X.25 (Note 1)

PC.232KV and PC.238AV, Purge and Vent Supply to Drywell Air X.25 ACAD 1305HV and ACAD 1306MV,. Supply to Drywell Air f

.026 (Note 1)

PC.231MV, PC.246AV, and PC 306 MV Purge and Vent' Air E:<haust from Drywell j

Air X.26 ACAD 1310KV, Bleed from Drywell Amendment No. 80,12,08.100.I03' 173 129,138 o