- ML20078C365 + (11:50:10, 26 May 2025)
- ML20078C356 + (11:50:11, 26 May 2025)
- ML20078C350 + (11:50:13, 26 May 2025)
- ML20078C342 + (11:50:15, 26 May 2025)
- ML20078C330 + (11:50:17, 26 May 2025)
- ML20078C315 + (11:50:19, 26 May 2025)
- ML20078C302 + (11:50:21, 26 May 2025)
- ML20078C300 + (11:50:25, 26 May 2025)
- ML20078C257 + (11:50:28, 26 May 2025)
- ML20078C226 + (11:50:30, 26 May 2025)
- ML20078C223 + (11:50:32, 26 May 2025)
- ML20078C153 + (11:50:39, 26 May 2025)
- ML20078C139 + (11:50:41, 26 May 2025)
- 05000316/LER-1983-083-03, /03L-0:on 830823,during Ice Condenser Lower Inlet Door Surveillance Test,Five Doors Exceeded Max Initial Opening Force Specs.Caused by Obstructions & Debris on Seals & Seating Surfaces.Procedure to Check Doors Modified + (11:50:48, 26 May 2025)
- 05000333/LER-1993-021, :on 930722,motor for 10MOV-25A RHR a Side LPCI Inboard Isolation Valve Failed Due to Inadequate Brake Design Test.Mod M1-90-174 Completed on Motor Actuators for 10MOV-25A & B + (11:50:55, 26 May 2025)
- 05000455/LER-1994-000, :on 940923,rod Drive 2BD Power Cabunet Urgent Failures & Subsequent Reactor Trip Occurred Due to Drop in Rcca.Rack Connector Socket for Group 2 Stationary Regulation Card Repaired + (11:51:13, 26 May 2025)
- 05000298/LER-1994-033, :on 941220,eight SRVs Removed & Sent to W Testing Facilities Because Four of SRV Lift Pressures Higher than Required Setpoint Tolerance.Caused by Design & Mfg.Ge Confirmed set-points Pose No Adverse Affects + (11:51:19, 26 May 2025)
- 05000219/LER-1994-018, :on 940924,containment Exhaust Valves Inadvertently Isolated Due to Improper Switch Position. Caused by Fabrication Deficiency.Four Isolated Valves Reopened & Surveillance Procedure Revised + (11:51:21, 26 May 2025)
- ML20078B826 + (11:51:35, 26 May 2025)
- 05000315/LER-1983-075-99, Discovered Check Valve RH-142 Exceeded Allowable Leak Rate.During Repairs,Disc Lapped & Seat Inspected.Check Valve Reinstalled W/New Gasket + (11:51:39, 26 May 2025)
- 05000362/LER-1983-063-03, /03L-0:on 830811,during Normal Start of Auxiliary Feedwater Pump Turbine,Steam Inlet Valve HV-4716 Did Not Open Completely.Cause of Valve Trip During Pump Starting Unknown.Valve Reset + (11:51:43, 26 May 2025)
- 05000255/LER-1983-060-01, /01T-0:on 830906,pipe Cap Removed from Containment Side of Penetration 21A,creating Open Path to Outside Containment.Caused by Procedural Inadequacy.Procedures Revised + (11:51:46, 26 May 2025)
- 05000325/LER-1994-015-01, :on 941215,HPCI Injection Valve Did Not Receive an Open Signal & No Injection Into Rv.Caused by Personnel Error.Use of Simpson 260 Meters Which Have Tone Position on Switch Has Been Discontinued + (11:51:50, 26 May 2025)
- 05000498/LER-1994-015, :on 940920,unit 1 Experienced Reactor Trip on low-low Steam Generator Level for Approx Four Minutes After Loss of Steam Generator Feedwater Pump.Caused by Expected Response Instead of Actual Conditions + (11:51:54, 26 May 2025)
- NRC-94-0097, Forwards Proprietary Documents Re Fermi 2 Turbine Generator Repairs,Actions Taken as Result of 931225 Event & Restart from Fourth Refueling Outage.Repts Withheld (Ref 10CFR2.790).W/4 Oversize Drawings + (11:51:56, 26 May 2025)
- 05000317/LER-1980-038-03, Control Room Air Conditioning Compressor 12 Tripped & Would Not Restart.On 800801 Compressor Tripped on Overcurrent.Caused by Amps Higher than Specs.Load Demand Adjusted + (11:53:13, 26 May 2025)
- 05000271/LER-1983-002-01, Leak Found in 2-inch SS Schedule 160 Elbow in Isolable Section of Reactor Drain Line.Caused by Intergranular Stress Corrosion Cracking.Elbow Replaced W/Type 304L Stainless Steel Matl + (11:53:19, 26 May 2025)
- 05000317/LER-1980-051-01, Control Room Air Conditioning Units 11 & 12 Failed During post-maint Testing. Temp Did Not Exceed Design Limit.Cause Not Stated. Unipressure Valves Replaced on hot-gas Bypass + (11:53:22, 26 May 2025)
- 05000317/LER-1980-049-03, Control Room Air Conditioning Unit 12 Tripped & Would Not Restart.Caused by High Discharge Pressure.Unipressure Valves Adjusted.Valves Replaced W/Hot Gas Bypass Valves + (11:53:29, 26 May 2025)
- 05000317/LER-1980-034-01, Control Room Air Conditioning Unit 11 Tripped Off.Unit 12 Immediately Started But Tripped.Caused by High Discharge Pressure.Unipressure Valves Adjusted + (11:53:32, 26 May 2025)
- 05000249/LER-1982-042-01, Excessive Amount of Water Discovered Leaking from Recirculating Seal Cavity 3B.Caused by Failure Due to Excessive Heat of Recirculation Pump 3B Rotating Hardface Seal (EPN24610) + (11:54:18, 26 May 2025)
- 05000317/LER-1980-039-03, Control Room Air Conditioning Compressor 12 Tripped.Unit Tripped Again on 800817.Caused by High Discharge Pressure.Unipressure Valves Adjusted + (11:54:20, 26 May 2025)
- IR 05000289/1977005 + (11:56:20, 26 May 2025)
- ML20077R687 + (11:56:58, 26 May 2025)
- 05000352/LER-1994-013, :on 941208,discovered That Isolation Valves Closed.Caused by Personnel Error Re Inadequate Position Verifications.Insp of Isolation Valves for Remaining Level Switches Performed Immediately + (11:57:00, 26 May 2025)
- ML20077R358 + (11:57:21, 26 May 2025)
- 05000361/LER-1983-067-01, Routine 6-month Surveillance of Fire Detection Supervisory Circuits Conducted Feb 1983 Did Not Demonstrate Operability of Fire Panel 3L-198.Caused by Inoperable Instrument + (11:57:31, 26 May 2025)
- 05000333/LER-1991-011, :on on 910617,walkdown of Panel Anchorage & Adjacent Panels Revealed Number of Anchorage Points Not Plug Welded to Existing Embedded Floor Steel.Caused by Original Const Error.Mod to Anchor Panels Initiated + (11:57:33, 26 May 2025)
- 05000247/LER-1983-015-03, Shutdown Initiated When Containment Spray Pump 21 Operability Criteria Not Met & Diesel Generator 23 Out of Svc for Maint.Pump 21 Removed from Svc Due to High Vibrations + (11:59:27, 26 May 2025)
- TAC:51991 + (12:00:05, 26 May 2025)
- ML20077N727 + (12:00:14, 26 May 2025)
- ML20077N025 + (12:00:56, 26 May 2025)
- 05000387/LER-1983-107-01, /01T-0:on 830818,spray Pond Riser Network a Inlet Manual Isolation Valve Would Travel Only in Closed Direction.Caused by Valve Operator Open Stopnut Moving Out of Position.Mechanical Stop Casing Loosened + (12:01:11, 26 May 2025)
- PMNS20200190, Forthcoming Meeting Between the U.S. Nuclear Regulatory Commission and the PWR Owners Group to Discuss PWROG-18029-NP, Component Reliability Data Issues for Discussion with NRC Research (Note: Meeting Time Is in the Mountain Time Zone) + (12:02:09, 26 May 2025)
- ML20077M187 + (12:02:30, 26 May 2025)
- ML20077L169 + (12:03:43, 26 May 2025)
- TAC:44300 + (12:04:03, 26 May 2025)
- TAC:44467 + (12:04:04, 26 May 2025)
- 05000325/LER-1983-019-03, /03L-0:on 830425,standby Liquid Control Sys Relief Valves 1-C41-F029A & B Lifted at Setpoints Exceeding Tech Specs.Caused by Out of Tolerance Relief Valve Settings. Valves Adjusted + (12:04:08, 26 May 2025)
- TAC:44398 + (12:04:12, 26 May 2025)
- A820021, Responds to NRC Re Violations Noted in IE Insp Rept 50-298/82-26.Corrective Actions:Qa Program Revised to Require Notification of Plant Mgt During Course of Evaluating Commercial Grade Relays for Safety Sys + (12:04:19, 26 May 2025)