- 05000354/LER-1996-004, :on 960229,discovered Required IST Surveillances for D Safety Auxiliaries Cooling Sys Pump & B Station Svc Water Pump Not Performed.Caused by Less than Adequate Oversight.Instruction Provided + (01:19:31, 26 May 2025)
- ML20101K425 + (01:19:36, 26 May 2025)
- ML20101K418 + (01:19:37, 26 May 2025)
- 05000483/LER-1992-008, :on 920305,boron Dilution Mitigation Sys Inoperability Noted.Caused by Design Oversight.Modification to Bdms & Revision of Bdms Setpoint Initiated + (01:19:39, 26 May 2025)
- ML20101K384 + (01:19:41, 26 May 2025)
- ML20101K374 + (01:19:43, 26 May 2025)
- 05000425/LER-1991-003, :on 910129,diesel Generator Nonvalid Failures Occurred Due to Reactive Power When Tying to Grid.Cause Not Identified.Transfer Relays Replaced & DG Demonstrated to Be Operable + (01:26:14, 26 May 2025)
- ML20101H288 + (01:27:44, 26 May 2025)
- ML20101H269 + (01:27:47, 26 May 2025)
- 05000352/LER-1984-013-02, :on 841120,outboard Isolation Valve for Shutdown Cooling Line Failed to Respond to Open Signal from Remote Shutdown Panel.Caused by Mechanical Interference. Lead Repositioned + (01:27:48, 26 May 2025)
- 05000353/LER-1992-005-02, :on 920605,EDG D21 Inadvertently Started Due to Personnel Error.Operator Involved Counseled on Importance of Procedure Compliance & Strict Attention to Detail + (01:27:49, 26 May 2025)
- 05000424/LER-1992-004, :on 920514,reactor Shut Down Due to Excessive Unidentified Leakage.Caused by Fatigue Failure.Metallurgical Analysis Underway to Confirm Failure Mechanism + (01:27:51, 26 May 2025)
- 05000354/LER-1992-006-02, :on 920525,suppression Chamber Inoperable Due to Suppression Chamber to Drywell Vacuum Breaker Failures. Inoperable Vacuum Breakers Repaired & Bypass Leakage Surveillance Completed Satisfactorily + (01:27:52, 26 May 2025)
- ML20101H245 + (01:27:53, 26 May 2025)
- ML20101H232 + (01:27:56, 26 May 2025)
- 05000366/LER-1992-006-02, :on 920522,vol of Liquid Radwaste Discharged W/O Monthly/Quarterly Composite Sample Having Been Updated. Caused by Personnel Errors.Responsible Personnel Counseled + (01:27:59, 26 May 2025)
- 05000457/LER-1992-003-08, :on 920527,2A Essential Svc Water Pump Automatically Started Due to Procedural Deficiency. Surveillance Procedure Will Be Revised + (01:28:02, 26 May 2025)
- ML20101G860 + (01:29:16, 26 May 2025)
- ML20101G841 + (01:29:19, 26 May 2025)
- ML20101G835 + (01:29:21, 26 May 2025)
- ML20101G830 + (01:29:22, 26 May 2025)
- ML20101G824 + (01:29:24, 26 May 2025)
- 05000254/LER-1996-003-02, :on 960222,unanticipated Start Occurred on Unit 1 Edg.Caused by Inadequate Guidance within Procedure Qcmms 6600-03.Procedure Qcmms 6600-03 Will Be Revised to Clarify Switch Settings + (01:29:29, 26 May 2025)
- ML20101G772 + (01:29:31, 26 May 2025)
- 05000325/LER-1992-016, :on 920402,fire Seals Around Diesel Generator Pedestals Found Outside Tss.Caused by Oil Leakage on Seals. Design Change Will Also Be Developed + (01:29:56, 26 May 2025)
- HL-2227, Forwards Renewal Application for NPDES Permit Ga 0004120,per ETSs Section 5.6.3.2 & May 1991 Rept Entitled, Relative Toxicities of Continuous & Intermittent Exposures of Chloride & Bromine.. + (01:30:39, 26 May 2025)
- TAC:M81256 + (01:30:46, 26 May 2025)
- TAC:56390 + (01:30:55, 26 May 2025)
- TAC:55704 + (01:31:06, 26 May 2025)
- TAC:69934 + (01:32:13, 26 May 2025)
- TAC:56337 + (01:33:49, 26 May 2025)
- 05000282/LER-1996-006, :on 960217,cooling Water Surveillance Tests Missed as Result of Rescheduling Error Occurred.Caused by Personnel Error.Surveillance Procedure Will Be re-written to Split Unit 1 + (01:33:55, 26 May 2025)
- 05000341/LER-1996-003, :on 960216,ECCS Outside Design Basis During ESF Bus 64C Undervoltage Protection Testing Occurred.Caused by Consequences of Bus 64C Udervoltage Testing Lineup.Dedicated Operator W/No Duties Stationed in CR + (01:33:56, 26 May 2025)
- ML20101D783 + (01:34:19, 26 May 2025)
- 05000354/LER-1995-038, :on 951127,failed to Comply W/Required Action Statement Upon Removal of Failed Snubber on RHR SDC Line.C/A to Avoid Unnecessary SDC Isolations & Associated Potential for Water Hammer Events Identified & Assigned in CAP + (01:34:37, 26 May 2025)
- ML20101D375 + (01:34:46, 26 May 2025)
- ML20101C666 + (01:35:47, 26 May 2025)
- 05000302/LER-1992-006, :on 920501,four safety-related Pipe Supports Did Not Meet Minimum Fs as Specified in NRC IE Bulletin 79-02.Caused by Design Oversight by Ae Firm in 1984.Sys Modified in Compliance W/Bulletin 79-02 + (01:36:57, 26 May 2025)
- TXX-9121, Discusses Confirmatory Testing of Thermo-Lag Fire Barrier Sys.Comprehensive Confirmatory Testing Program Initiated to Envelope Full Range of Protected Conduit & Cable Tray Configurations.Testing Scheduled for Second Wk in June + (01:38:07, 26 May 2025)
- ML20101A865 + (01:38:36, 26 May 2025)
- TXX-9217, Forwards Evaluation of Indication Discovered in Nozzle to Channel Head Weld on Tube Side Outlet Nozzle of RHR HX (TBX-RHAHRS-01) During First Refueling Outage ASME Section XI ISI Exam.Weld Will Be Reexam During Next Insp Period + (01:39:13, 26 May 2025)
- 05000498/LER-1989-017, Informs NRC of Change to Commitment Made as Result of LER 89-017 Re Event Involving Inadvertent Contamination of Nonradioactive Sys on 890814.Mods 89228,89229,89239 & 89231 No Longer Necessary.Justification Included + (01:39:25, 26 May 2025)
- ML20100R440 + (01:39:50, 26 May 2025)
- L-96-004, Monthly Operating Repts for Feb 1996 for Point Beach Nuclear Plant,Units 1 & 2 + (01:40:13, 26 May 2025)
- 05000341/LER-1996-001, :on 960205,EDG CW Function Potentially Lost Due to Ice Formation in Pump Columns.Performed Operability Determination on Dgsw Pumps B & C + (01:40:28, 26 May 2025)
- 05000369/LER-1984-029, :on 841029,concentration of Nitrogen in Upper Head Injection Accumulator Exceeded Tech Spec Limits.Caused by Repetitive Continuous Makeup to Accumulator from Upper Head Injection Surge Tank + (01:41:15, 26 May 2025)
- 05000482/LER-1996-002, :on 960130,lost a Train ESW Due to Icing on Trash Racks.Contingency Plans Developed to Be Implemented Whenever Lake Temp Drops to 40F or Lower & Air Bubblers Being Maintained in Outer Bays to Sweep Frazil Ice + (01:41:31, 26 May 2025)
- 05000261/LER-1981-002-01, /01T-3:on 810113,review of Svc Water Sys Revealed Potential Unmonitored Release Path to Environ.Caused by Lack of Radiation Monitoring on Svc Water Return Lines from Containment.Discharge Lines Modified + (01:42:12, 26 May 2025)
- 05000255/LER-1984-022, :on 840704,containment Dome Temp Measured at 138 F.Determined Reportable on 841022.Caused by Personnel Error.Containment Temp Limits Established + (01:43:19, 26 May 2025)
- TAC:65303 + (01:44:37, 26 May 2025)
- ML20100L151 + (01:46:54, 26 May 2025)