Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19332F905 + (22:56:42, 25 December 2024)
- LIC-89-1142, Responds to NRC Re Violations Noted in Insp Rept 50-285/89-27.Corrective Actions:Replacement of Failed Differential Transmitter DPT-1039 Will Be Completed by 900131 & Procedures Re Speed Control Loop Issued by 900210 + (22:56:44, 25 December 2024)
- ML19332F902 + (22:56:44, 25 December 2024)
- ML19332F900 + (22:56:47, 25 December 2024)
- 05000461/LER-1989-036, :on 891113,incorrect Connection of Source to Terminals Directly Below Correct Terminals Caused Div 1 Isolation of RCIC Sys.Caused by Personnel Error.Personnel Briefed on Need to Use Ladders/Stools + (22:56:49, 25 December 2024)
- ML19332F896 + (22:56:51, 25 December 2024)
- 05000346/LER-1989-017, :on 891113,containment Spray Pump 1-1 Inadvertently Started During Monthly Functional Test in Safety Features Actuation Sys (Sfas) Channel 1.Caused by Failed Relay in Sfas Channel 3.Relay Replaced + (22:56:52, 25 December 2024)
- ML19332F890 + (22:56:54, 25 December 2024)
- ML19332F885 + (22:56:55, 25 December 2024)
- ML19332F883 + (22:56:56, 25 December 2024)
- ML19332F880 + (22:56:57, 25 December 2024)
- ML19332F879 + (22:56:58, 25 December 2024)
- ML19332F873 + (22:56:59, 25 December 2024)
- 05000321/LER-1989-018-02, :on 891114,sys High Differential Flow Condition Occurred Causing Actuation of Primary Containment Isolation Sys Valve Group 5 Logic Resulting in Closure of RWCU Valve. Caused by Personnel Error.Personnel Counseled + (22:57:00, 25 December 2024)
- ML19332F867 + (22:57:01, 25 December 2024)
- ML19332F866 + (22:57:06, 25 December 2024)
- 05000352/LER-1989-056, :on 891119,unexpected Nuclear Steam Supply Shutoff Sys Group Iii,Div 4 Isolation Initiated ESF Actuation.Caused by Defective read-set Selector Switch. Switch Repositioned + (22:57:07, 25 December 2024)
- ML19332F862 + (22:57:08, 25 December 2024)
- ML19332F860 + (22:57:18, 25 December 2024)
- ML19332F859 + (22:57:19, 25 December 2024)
- ML19332F856 + (22:58:25, 25 December 2024)
- ML19332F852 + (22:58:27, 25 December 2024)
- PNO-V-89-072, on 891208,licensee Completed Defueling of Reactor.Spent Fuel Pool Presently Contains 493 Fuel Assemblies.Efforts to Correct Minor Spent Fuel Pool Leak Underway + (22:58:27, 25 December 2024)
- ML19332F849 + (22:58:29, 25 December 2024)
- ML19332F850 + (22:58:29, 25 December 2024)
- ML19332F847 + (22:58:31, 25 December 2024)
- ML19332F843 + (22:58:32, 25 December 2024)
- ML19332F846 + (22:58:32, 25 December 2024)
- ML19332F842 + (22:58:33, 25 December 2024)
- IR 05000213/1989022 + (22:58:34, 25 December 2024)
- ML19332F840 + (22:58:36, 25 December 2024)
- ML19332F839 + (22:58:37, 25 December 2024)
- ML19332F835 + (22:58:38, 25 December 2024)
- ML19332F837 + (22:58:38, 25 December 2024)
- ML19332F833 + (22:58:39, 25 December 2024)
- ML19332F830 + (22:58:45, 25 December 2024)
- ML19332F825 + (22:58:46, 25 December 2024)
- ML19332F818 + (22:58:47, 25 December 2024)
- ML19332F819 + (22:58:47, 25 December 2024)
- ML19332F815 + (22:58:48, 25 December 2024)
- 05000327/LER-1989-028, :on 891115,penetration Room Developed Noble Gas High Airborne Radioactivity Excursion of 86.1 Max Permissible Concentration Fraction.Caused by Inadequate Latching Mechanism on Access Door + (22:58:52, 25 December 2024)
- 05000341/LER-1989-031, :on 891120,both Div II Emergency Equipment Cooling Water (EECW) & Emergency Equipment Svc Water Sys Pumps Tripped Immediately.Caused by Inadequacies in Stated Procedures.Procedures Revised + (22:58:57, 25 December 2024)
- ML19332F805 + (22:59:00, 25 December 2024)
- 3F1289-12, Forwards Revised Justification for Continued Operation, Including Updated Status of Corrective Action Planned for Refuel 7.Util Will Upgrade low-range Instrumentation to safety-grade During Refueling Outage + (22:59:01, 25 December 2024)
- ML19332F802 + (22:59:03, 25 December 2024)
- NRC-89-0257, Ro:On 891115,second Start Failure of Emergency Diesel Generator 14 Occurred.Caused by Test Personnel Incorrectly Determining ECCS Signal Voltage & Frequency.Surveillances Completed,Indicating That Problem self-corrected + (22:59:06, 25 December 2024)
- 05000341/LER-1989-025, :on 891115,low Level 2 Signal Unintentionally Induced During Reactor Pressure Vessel Hydrostatic Pressure Test.Caused by Personnel Error.Personnel Counseled on Notifying & Coordinating Instrument Lineups + (22:59:08, 25 December 2024)
- 3F1289-04, Requests Temporary Exemption from Emergency Diesel Generator Upgrade,Per GDC 2,to Permit Temporary Removal of Steel Encls Which Provide Missile Protection for Two Emergency Diesel Generators.Diagram of Missile Shields to Be Removed Encl + (22:59:12, 25 December 2024)
- PY-CEI-NRR-1081, Responds to NRC 890531 Request for Addl Info Re NRC Bulletin 88-004, Safety-Related Pump Loss. Info Covers pump-to-pump Interaction That Could Result in Deadheading & Adequacy of Min Flow Bypass Lines Against Pump Damage + (22:59:16, 25 December 2024)
- ML19332F793 + (22:59:18, 25 December 2024)
- RBG-31940, Forwards Cajun Electric Power Cooperative,Inc Audited Financial Statements for 1988 Since Annual Rept Will Not Be Compiled + (22:59:19, 25 December 2024)
- ML19332F787 + (22:59:21, 25 December 2024)