Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20154J031 + (16:25:11, 24 May 2025)
- ML20154J022 + (16:25:14, 24 May 2025)
- ML20154J007 + (16:25:19, 24 May 2025)
- ML20154J000 + (16:25:22, 24 May 2025)
- ML20154H995 + (16:25:24, 24 May 2025)
- ML20154H992 + (16:25:26, 24 May 2025)
- ML20154H930 + (16:25:43, 24 May 2025)
- ML20154H817 + (16:26:20, 24 May 2025)
- ML20154H718 + (16:26:54, 24 May 2025)
- IR 05000206/1988017 + (16:26:55, 24 May 2025)
- ML20154H709 + (16:26:58, 24 May 2025)
- PM-98-046, Requests Mod to Release Plan for Northwest CaF2 Storage Area,Incorporating Recent Guidance Into Final Survey & Release Plan.Revised Wording to Sections 4r.3-4.5 of Current Plan.Extension of Current Schedule to 990416,is Requested + (16:27:01, 24 May 2025)
- 05000361/LER-1998-019, :on 980911,oxygen Monitor Setpoint Exceeded TS Limits.Cause Unknown Due to Passage of Time.Wghs Oxygen Concentration Instrument Setpoints Were Lowered to Incorporate Calculated Tlu + (16:27:05, 24 May 2025)
- 05000361/LER-1998-011-01, Forwards LER 98-011-01,re Inadequate Surveillance Test of Logarithmic Power Trip Bypass Removal Function.No New Commitments Are Made by Util + (16:27:15, 24 May 2025)
- 05000361/LER-1998-006-01, Forwards LER 98-006-01,re Event Involving Missed TS Surveillance.Sce Is Submitting Revised TS to Provide Addl Info Re Missed TS + (16:27:21, 24 May 2025)
- ML20154H599 + (16:27:35, 24 May 2025)
- ML20154H583 + (16:27:41, 24 May 2025)
- 05000271/LER-1988-004, :on 880420,manual Isolation Valves in Supply & Return Lines to Two Advanced Offgas Radiation Monitors Closed Preventing Supervision of Stream Radiation Levels. Caused by Personnel Leaving Drain Closed + (16:27:52, 24 May 2025)
- 05000458/LER-1998-003-01, Forwards LER 98-003-01,suppl to Previous Submittal Dtd 980724.Rept Addressed Adequacy of Control Air Supplies to DGs & Initially Submitted as Voluntary Rept + (16:27:57, 24 May 2025)
- 05000341/LER-1985-082, :on 851204,determined That Embedded Support Plates in Reactor Auxiliary Bldg Potentially Overloaded. Embedded Plates Acceptable,Based on Sargent & Lundy Analyses.Design Changes Do Not Affect Plates + (16:28:05, 24 May 2025)
- ML20154H487 + (16:28:09, 24 May 2025)
- 05000341/LER-1998-009, :on 980914,inadvertent Deenergization of Safety Bus 72F While Transferring from Alternate to Normal Power Resulted in ESF Actuations.Caused by Personnel Error. Operator Involved Was Counseled.With + (16:28:22, 24 May 2025)
- ML20154H410 + (16:28:42, 24 May 2025)
- 05000272/LER-1986-003, :on 860131,reactor Trip Occurred on Steam Generator 11 Due to Valve Partially Closing & Failure to Respond to Manual Control.Caused by Leak on Valve 11BF40 Positioner.Valve Replaced + (16:28:46, 24 May 2025)
- 05000267/LER-1986-011, :on 860201,automatic Loop 2 Shutdown Initiated on High Reheat Header Activity.Caused by Voltage Spike When RIS-93252-11 Manually Tripped Causing RIS-93251-11 to Trip. Station Svc Request Initiated to Test Switch + (16:28:58, 24 May 2025)
- ML20154H340 + (16:29:03, 24 May 2025)
- 05000397/LER-1986-001, :on 860209,spurious Actuation of Control Room Emergency Filtration Sys Occurred Due to Chlorine Monitor Tape Depletion.Caused by Inadequate Design & Personnel Error.Tape Replaced + (16:29:23, 24 May 2025)
- TAC:62736 + (16:29:46, 24 May 2025)
- ML20154H089 + (16:30:21, 24 May 2025)
- ML20154G888 + (16:31:09, 24 May 2025)
- ML20154G864 + (16:31:15, 24 May 2025)
- TAC:62929 + (16:31:26, 24 May 2025)
- TAC:00090 + (16:31:44, 24 May 2025)
- NUREG-0837, Discusses Data Suggesting That Factors Other than Operation of & Releases from Facility Affecting Results of Environ Monitoring Program Re Resin Release in June 1982.Higher Dose Readings & 1982 Release Coincidental.Related Info Encl + (16:32:24, 24 May 2025)
- 05000266/LER-1998-003-01, Forwards LER 98-003-01 Re Discovery That Flow Rates Were Outside Design Basis of Plant.Rept Revises Corrective Action Commitment Re Replacement of SW Piping to Unit 2 Fan Cooler Motor Heat Exchangers + (16:32:36, 24 May 2025)
- ML20154G534 + (16:32:44, 24 May 2025)
- ML20154G472 + (16:32:59, 24 May 2025)
- ML20154G401 + (16:33:13, 24 May 2025)
- ML20154G298 + (16:33:37, 24 May 2025)
- ML20154G267 + (16:33:45, 24 May 2025)
- 05000382/LER-1997-032-01, Forwards LER 97-032-01,re Details of Noncompliance with Plant TS Due to Failure to Meet GDC 54,per 10CFR50.73 (a)(2)(i)(B) + (16:33:54, 24 May 2025)
- ML20154F991 + (16:34:55, 24 May 2025)
- ML20154F934 + (16:35:07, 24 May 2025)
- ML20154F887 + (16:35:18, 24 May 2025)
- ML20154F853 + (16:35:27, 24 May 2025)
- IR 05000010/1998016 + (16:36:39, 24 May 2025)
- ML20154F599 + (16:36:51, 24 May 2025)
- ML20154F497 + (16:37:16, 24 May 2025)
- 05000293/LER-1998-021, :on 980902,inadequate Fuel Supply for EDGs Was Noted.Root Cause Analysis Is Being Performed.Revised Calculation Control Process to Ensure Consistency with FSAR + (16:37:33, 24 May 2025)
- 05000341/LER-1998-007, :on 980908,inadvertent Deenergization of Safety Buses During Performance of Surveillance Testing Resulted in ESF Actuations.Caused by Faulty Static Underfrequency Relay. Relay Was Removed & Benched Tested + (16:37:50, 24 May 2025)
- ML20154F355 + (16:37:54, 24 May 2025)