Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000317/1980017 + (14:34:06, 24 December 2024)
- ML19345D907 + (14:34:07, 24 December 2024)
- ML19345D905 + (14:34:08, 24 December 2024)
- ML19345D903 + (14:34:12, 24 December 2024)
- ML19345D902 + (14:34:13, 24 December 2024)
- ML19345D900 + (14:34:14, 24 December 2024)
- ML19345D899 + (14:34:15, 24 December 2024)
- ML19345D897 + (14:34:16, 24 December 2024)
- IR 05000029/1980017 + (14:34:18, 24 December 2024)
- ML19345D895 + (14:34:19, 24 December 2024)
- ML19345D893 + (14:34:20, 24 December 2024)
- ML19345D892 + (14:34:21, 24 December 2024)
- ML19345D890 + (14:34:23, 24 December 2024)
- ML19345D889 + (14:34:23, 24 December 2024)
- ML19345D888 + (14:34:24, 24 December 2024)
- ML19345D886 + (14:34:24, 24 December 2024)
- ML19345D885 + (14:34:26, 24 December 2024)
- ML19345D884 + (14:34:27, 24 December 2024)
- ML19345D883 + (14:34:29, 24 December 2024)
- ML19345D882 + (14:34:31, 24 December 2024)
- ML19345D880 + (14:34:32, 24 December 2024)
- ML19345D879 + (14:34:34, 24 December 2024)
- ML19345D878 + (14:34:35, 24 December 2024)
- ML19345D877 + (14:34:37, 24 December 2024)
- ML19345D876 + (14:34:37, 24 December 2024)
- ML19345D874 + (14:34:38, 24 December 2024)
- ML19345D872 + (14:34:39, 24 December 2024)
- 05000278/LER-1980-027-01, /01T-0:on 801124,HPCI Valve MO-3-23-14 Kept Driving in Closed Direction Causing Valve Fuses to Blow. Probably Caused by Improper Adjustment of Valve Closing Torque Switch.Valve Disassembled,Inspected & Tested + (14:34:40, 24 December 2024)
- 05000281/LER-1980-041-03, /03L-0:on 801112,snubber 2-WFPD-HSS-18 Found to Have Bent rod-eye & Was Declared Inoperable.Caused by Improper Alignment of Pipe Clamp to Snubber.Snubber Replaced + (14:34:45, 24 December 2024)
- ML19345D868 + (14:34:48, 24 December 2024)
- 05000278/LER-1980-027, Forwards LER 80-027/01T-0 + (14:34:49, 24 December 2024)
- 05000368/LER-1980-084-03, /03L-0:on 801118,valve Stroke Time of MSIV 2CV-1010 Exceeded Limit.Caused by Valve Internal Damper Adjustment Drift.Valve Adjusted & Retested + (14:34:51, 24 December 2024)
- 05000324/LER-1980-082-03, /03L-0:on 801114,Unit 2 Reactor Scrammed.During Subsequent Startup,Coolant Activity Exceeded Tech Specs. Caused by Leaking Fuel Element.Fuel Bundles Will Be Sipped During Next Refueling & Leaking Bundles Removed + (14:34:59, 24 December 2024)
- ML19345D861 + (14:35:01, 24 December 2024)
- 05000368/LER-1980-084, Forwards LER 80-084/03L-0 + (14:35:03, 24 December 2024)
- 05000304/LER-1980-028-03, /03L-0:on 801110,steam Generator 2B Feed Flow Channel 2F-540 Out of Tolerance.Caused by Zero Shifting of Fisher Porter Transmitter.Transmitter Zero Adjusted & Channel Returned to Svc + (14:35:05, 24 December 2024)
- 05000301/LER-1980-010-03, /03L-0:on 801117,safety Injection Pump 2P15A Motor & Pump Shaft to Coupling Keys Found to Be Sheared.Cause Undetermined.Pump & Motor Checked for Damage,Keys Replaced & Pump Operability Verified + (14:35:07, 24 December 2024)
- 05000324/LER-1980-082, Forwards LER 80-082/03L-0 + (14:35:09, 24 December 2024)
- 05000296/LER-1980-052-03, /03L-0:on 801118,recirculation Discharge Valve Activation Pressure Switch 3-PS-68-95,switch 1,found Below Tech Spec Limit by 8%.Caused by Instrument Drift.Switch Recalibr & Tested.Switch to Be Replaced + (14:35:11, 24 December 2024)
- 05000304/LER-1980-028, Forwards LER 80-028/03L-0 + (14:35:13, 24 December 2024)
- 05000301/LER-1980-012-03, /03L-0:on 801202,slippage Found in Shaft Driven Seal Water Pump Impeller Resulting in Overheating of Throttle Bushing.Caused by Reduced Seal Water Flow Due to Loosening of Pumping Ring.Shaft Sleeve & Bushing Replaced + (14:35:15, 24 December 2024)
- 05000327/LER-1980-187-03, /03L-0:on 801118,found Vital Instrument Power Board 2-III Being Powered from Maint Power Supply.Caused by Failure of Vital Inverter 2-III.Inverter Restored + (14:35:17, 24 December 2024)
- 05000301/LER-1980-011-03, /03L-0:on 801118,axial Flux Difference Deviated from Target Band.Caused by Improper Interpretation of Tech Specs Resulting in Failure to Lower High Neutron Flux Setpoint.Instruction Clarified + (14:35:19, 24 December 2024)
- 05000296/LER-1980-052, Forwards LER 80-052/03L-0 + (14:35:21, 24 December 2024)
- 05000327/LER-1980-187, Forwards LER 80-187/03L-0 + (14:35:22, 24 December 2024)
- 05000301/LER-1980-012, Forwards LER 80-012/03L-0 + (14:35:24, 24 December 2024)
- 05000296/LER-1980-050-03, /03L-0:on 801115,breaker for Standby Liquid Control Pump B Motor Tripped When Pump Started.Caused by Overcurrent Tripping Device on B Phase Tripping at Lower Value than Other Phases.Breaker Replaced + (14:35:26, 24 December 2024)
- ML19345D841 + (14:35:28, 24 December 2024)
- 05000301/LER-1980-010, Forwards LER 80-010/03L-0 + (14:35:30, 24 December 2024)
- ML19345D838 + (14:35:31, 24 December 2024)
- 05000301/LER-1980-011, Forwards LER 80-011/03L-0 + (14:35:33, 24 December 2024)