Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19347A998 + (11:39:41, 24 December 2024)
- ML19347A997 + (11:39:45, 24 December 2024)
- ML19347A995 + (11:39:46, 24 December 2024)
- ML19347A992 + (11:39:47, 24 December 2024)
- ML19347A994 + (11:39:47, 24 December 2024)
- ML19347A990 + (11:39:48, 24 December 2024)
- ML19347A989 + (11:39:49, 24 December 2024)
- ML19347A988 + (11:39:50, 24 December 2024)
- ML19347A985 + (11:39:51, 24 December 2024)
- PNO-I-80-129, on 800914,plant Was Shutdown When One of Three Seals Failed on Three Reactor Coolant Pump.Shutdown Expected to Last Until 800918 + (11:39:53, 24 December 2024)
- ML19347A981 + (11:39:54, 24 December 2024)
- ML19347A980 + (11:39:55, 24 December 2024)
- ML19347A978 + (11:39:56, 24 December 2024)
- ML19347A976 + (11:39:57, 24 December 2024)
- ML19347A975 + (11:39:58, 24 December 2024)
- ML19347A973 + (11:39:59, 24 December 2024)
- ML19347A972 + (11:40:00, 24 December 2024)
- ML19347A971 + (11:40:01, 24 December 2024)
- ML19347A969 + (11:40:02, 24 December 2024)
- 05000348/LER-1980-050-03, /03L-0:on 800825,svc Water Train B Dc Distribution Sys Declared Inoperable When No Output Indication from Battery Charger 4 Was Observed.Caused by Actuation of High Voltage Shutdown Relay.Reset & Returned to Svc + (11:40:04, 24 December 2024)
- ML19347A967 + (11:40:05, 24 December 2024)
- ML19347A965 + (11:40:05, 24 December 2024)
- 05000348/LER-1980-050, Forwards LER 80-050/03L-0 + (11:40:07, 24 December 2024)
- IR 05000367/1980002 + (11:40:08, 24 December 2024)
- ML19347A961 + (11:40:09, 24 December 2024)
- 05000219/LER-1980-038-03, /03L-0:on 800826,during Surveillance Testing of Reactor Triple Low Water Level sensors,RE18B Tripped at Level Less Conservative than Tech Spec Limits.Caused by Sensor Repeatability.Sensor Reset within Prescribed Limits + (11:40:11, 24 December 2024)
- 05000325/LER-1980-070-03, /03L-0:on 800828,during Normal Operation,Several Alarms Received from Diesel Generator 1.Cause Not Determined.Alarm Relays Reset,Generator Tested & Returned to Svc.Update Rept to Be Submitted Upon Discovery of Cause + (11:40:13, 24 December 2024)
- 05000259/LER-1980-068-01, /01T-0:on 800901,fire Protection Sys Insp Not Performed as Required by Tech Spec.Caused by Failure to Obtain Consultant Svcs within Specified Time Interval.Insp to Be Performed at Earliest Possible Date + (11:40:15, 24 December 2024)
- ML19347A955 + (11:40:17, 24 December 2024)
- ML19347A953 + (11:40:18, 24 December 2024)
- 05000219/LER-1980-038, Forwards LER 80-038/03L-0 + (11:40:23, 24 December 2024)
- 05000259/LER-1980-068, Forwards LER 80-068/01T-0 + (11:40:27, 24 December 2024)
- ML19347A947 + (11:40:29, 24 December 2024)
- 05000325/LER-1980-070, Forwards LER 80-070/03L-0 + (11:40:30, 24 December 2024)
- 05000267/LER-1980-047, Forwards LER 80-047/03L-0 + (11:40:34, 24 December 2024)
- ML19347A940 + (11:40:35, 24 December 2024)
- 05000296/LER-1980-035-03, /03L-0:on 800901, a Reactor Recirculation Pump Tripped.Caused Undetermined.Unit Load Reduced to 700 Mw & Pump Restarted in 6-h + (11:40:36, 24 December 2024)
- 05000368/LER-1980-063-03, /03L-0:on 800822,after Unit Trip at 90%,power a Condensate Storage Tank Level Fell Below Tech Spec Min. Caused by Emergency Feedwater Sys.Suction Taken from Tank After Unit Trip.Procedures Revised to Prevent Reoccurrence + (11:40:39, 24 December 2024)
- ML19347A935 + (11:40:40, 24 December 2024)
- 05000296/LER-1980-035, Forwards LER 80-035/03L-0 + (11:40:41, 24 December 2024)
- ML19347A932 + (11:40:42, 24 December 2024)
- 05000285/LER-1980-021-03, /03L-0:on 800910,transformer T4 of DG-1 Failed. Transformer Feeds Diesel Oil Immersion Heater & Alarm Relays.Caused by Moveable Armature Located on Immersion Heater Contractor.Armature Repaired + (11:40:43, 24 December 2024)
- 05000368/LER-1980-063, Forwards LER 80-063/03L-0 + (11:40:45, 24 December 2024)
- ML19347A928 + (11:40:46, 24 December 2024)
- ML19347A926 + (11:40:49, 24 December 2024)
- ML19347A924 + (11:40:49, 24 December 2024)
- 05000285/LER-1980-021, Forwards LER 80-021/03L-0 + (11:40:51, 24 December 2024)
- ML19347A919 + (11:40:54, 24 December 2024)
- 05000219/LER-1980-039-03, /03L-0:on 800829,during Low Pressure Main Steam Line Functional Test & calibr,RE23B & 23D Pressure Switches Actuated at Valve Above Tech Spec Limits.Caused by Instrument Repeatability.Switches Reset to Desired Limit + (11:40:55, 24 December 2024)
- 05000348/LER-1980-051-03, /03L-0:on 800826,diesel Generator 1C Failed to Reach Speed within Specified Limits.Apparent Cause Was Leaking Check Valve in Fuel Oil Sys.Valve Replaced & Diesel Generator Returned to Svc + (11:40:57, 24 December 2024)
- 05000366/LER-1980-128-03, /03L-0:on 800905,reactor High Pressure Instruments 2B21-N023C & D Actuated Above Tech Specs.Caused by Setpoint Drift.Switches Recalibr & Tested Successfully + (11:40:59, 24 December 2024)