- 05000312/LER-1980-047-01, /01T-0:on 801222,IE Bulletin 79-01B Review Found Lack of Qualification Documentation for Flow Transmitter Utilized to Establish Dilution Flow to Prevent Boron Precipitation Following Loca.Cause Not Stated + (22:42:17, 23 December 2024)
- 05000295/LER-1980-053-03, /03L-0:on 800825,component Cooling Liquid Rad Monitor 1RE 0017 Did Not Respond to Check Source & Indicator Was at Bottom of Scale.Caused by Drift in Monitor Plateau. Plateau Reset + (22:42:19, 23 December 2024)
- 05000334/LER-1980-105-03, /03L-0:on 801205,thermocouple Readings Indicated Temps Below Tech Spec Level Around Boron Injection Tank Outlet Isolation Valves.Caused by Thermocouples Not in Full Contact W/Pipes.Heat Tracing Sys Study Is Being Conducted + (22:42:21, 23 December 2024)
- 05000334/LER-1980-105, Forwards LER 80-105/03L-0 + (22:42:22, 23 December 2024)
- 05000296/LER-1980-058-03, /03L-0:on 801207,MSIV 1-14,1-15,1-26,1-27,1-37 & 1-38 & 1-51 Found Leaking.Caused by Seating Surface Deterioration Due to Normal Wear.Valves Repaired + (22:42:24, 23 December 2024)
- 05000339/LER-1980-099, Forwards LER 80-099/03L-0 + (22:42:26, 23 December 2024)
- 05000312/LER-1980-047, Forwards LER 80-047/01T-0 + (22:42:28, 23 December 2024)
- 05000339/LER-1980-097-03, /03L-0:on 801209 & 10,containment Penetration Conductor for Polar Crane Energized in Mode for Which Breaker Overload Protection Not Qualified.Caused by Closing Breaker 2B1-2A3 for Insp & Work Completion + (22:42:29, 23 December 2024)
- 05000339/LER-1980-098-03, /03L-0:on 801208,individual Rod Position Indication for Rod J-9 in Shutdown Bank B Deviated from Demand Position by More than 12 Steps.Caused by Instrument Drift.Rod Position Indicator Channel Recalibr + (22:42:33, 23 December 2024)
- 05000339/LER-1980-097, Forwards LER 80-097/03L-0 + (22:42:35, 23 December 2024)
- 05000296/LER-1980-058, Forwards LER 80-058/03L-0 + (22:42:38, 23 December 2024)
- 05000339/LER-1980-098, Forwards LER 80-098/03L-0 + (22:42:40, 23 December 2024)
- 05000295/LER-1980-053, Forwards LER 80-053/03L-0 + (22:42:42, 23 December 2024)
- ML19351F542 + (22:42:43, 23 December 2024)
- 05000295/LER-1980-054, Forwards LER 80-054/03L-0 + (22:42:45, 23 December 2024)
- 05000338/LER-1980-105, Forwards LER 80-105/03L-0 + (22:42:47, 23 December 2024)
- ML19351F536 + (22:42:50, 23 December 2024)
- 05000334/LER-1980-109-03, /03L-0:on 801208,axial Flux Difference Increased Above Target Band.Caused by High Initial Second Fuel Cycle 100% Target Flux Value.Target Flux Value Lowered + (22:42:51, 23 December 2024)
- 05000368/LER-1980-056, Forwards Updated LER 80-056/03X-1 + (22:42:53, 23 December 2024)
- ML19351F531 + (22:42:55, 23 December 2024)
- 05000260/LER-1980-056-03, /03L-0:on 801215,reactor Water Level Switch LIS-3-56A Switch 2 Setpoint Found Outside of Tech Spec Limits.Caused by Yarway Model 4418c Setpoint Drift.Switch Recalibr & Functionally Tested for Repeatability + (22:42:56, 23 December 2024)
- 05000334/LER-1980-107-03, /03L-0:on 801206,electrolyte for Detectors 101A & 101B Found Not Dripping.Caused by Clogged Wick & Glass Orifice.Wick & Orifice Cleaned & Top Vent Filter Loosened + (22:42:58, 23 December 2024)
- 05000260/LER-1980-056, Forwards LER 80-056/03L-0 + (22:43:00, 23 December 2024)
- 05000334/LER-1980-106-03, /03L-0:on 801206,inner Door of Containment Air Lock Failed Surveillance Leakage Test Per Tech Spec.Cause Not stated.O-rings Greased & Valves Tightened + (22:43:01, 23 December 2024)
- ML19351F525 + (22:43:06, 23 December 2024)
- 05000334/LER-1980-104-03, /03L-0:on 801204,F-476 Feed Flow Protection Channel for 1A Steam Generator Failed Surveillance Test. Caused by Bad Clock Board Allowing Loop Voltage Drift on Steam Flow Input.Clock Pulse Adjusted + (22:43:07, 23 December 2024)
- ML19351F523 + (22:43:09, 23 December 2024)
- ML19351F521 + (22:43:09, 23 December 2024)
- ML19351F520 + (22:43:11, 23 December 2024)
- ML19351F516 + (22:43:13, 23 December 2024)
- ML19351F515 + (22:43:14, 23 December 2024)
- ML19351F514 + (22:43:14, 23 December 2024)
- ML19351F513 + (22:43:17, 23 December 2024)
- ML19351F512 + (22:43:17, 23 December 2024)
- ML19351F511 + (22:43:18, 23 December 2024)
- ML19351F510 + (22:43:19, 23 December 2024)
- ML19351F509 + (22:43:19, 23 December 2024)
- ML19351F507 + (22:43:20, 23 December 2024)
- ML19351F506 + (22:43:21, 23 December 2024)
- 05000285/LER-1980-030-03, /03L-0:801211,diesel Generator 1 Failed to Start on Secondary Air Sys.Caused by Vanes of Air Motor Sticking & Preventing Motors from Turning.Vanes Cleaned & Motors Installed + (22:43:23, 23 December 2024)
- ML19351F504 + (22:43:24, 23 December 2024)
- ML19351F502 + (22:43:25, 23 December 2024)
- 05000285/LER-1980-030, Forwards LER 80-030/03L-0 + (22:43:26, 23 December 2024)
- ML19351F499 + (22:43:27, 23 December 2024)
- ML19351F498 + (22:43:28, 23 December 2024)
- ML19351F497 + (22:43:28, 23 December 2024)
- ML19351F496 + (22:43:31, 23 December 2024)
- ML19351F495 + (22:43:34, 23 December 2024)
- ML19351F494 + (22:43:35, 23 December 2024)
- ML19351F493 + (22:43:36, 23 December 2024)
- ML19351F490 + (22:43:37, 23 December 2024)