Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000339/LER-1980-104, Forwards LER 80-104/03L-0 + (20:24:57, 23 December 2024)
- ML20002D350 + (20:24:58, 23 December 2024)
- ML20002D349 + (20:24:59, 23 December 2024)
- 05000338/LER-1980-107-03, /03L-0:on 801226,while Operating at 59% Power, Steam Generator 1B Steam Pressure Channel II Observed Indicating High,Resulting in Channel Being Locked In.Caused by Sensing Line for Pressure Transmitter 1484 Freezing + (20:25:00, 23 December 2024)
- ML20002D347 + (20:25:01, 23 December 2024)
- ML20002D346 + (20:25:02, 23 December 2024)
- ML20002D345 + (20:25:02, 23 December 2024)
- 05000338/LER-1980-107, Forwards LER 80-107/03L-0 + (20:25:03, 23 December 2024)
- ML20002D342 + (20:25:04, 23 December 2024)
- ML20002D339 + (20:25:06, 23 December 2024)
- ML20002D340 + (20:25:06, 23 December 2024)
- ML20002D338 + (20:25:07, 23 December 2024)
- ML20002D337 + (20:25:07, 23 December 2024)
- ML20002D335 + (20:25:08, 23 December 2024)
- 05000368/LER-1980-092-03, /03L-0:on 801222,emergency Control Room Chiller 2VE-1A Compressor Failed to Start.Caused by Freon Migration Due to Cold Ambient Temp Affect on Sys.Mod Being Evaluated to Add Time Delay on Interlocks to Allow Low Temp Starts + (20:25:09, 23 December 2024)
- 05000368/LER-1980-092, Forwards LER 80-092/03L-0 + (20:25:11, 23 December 2024)
- ML20002D328 + (20:25:12, 23 December 2024)
- ML20002D330 + (20:25:12, 23 December 2024)
- 05000368/LER-1980-093-03, /03L-0:on 801220,emergency Diesel Generator 2 Tripped on Reverse Power on Breaker Closure.Caused by Operator Applying Manual Generator Load Increase Too Slowly. Operators Instructed on Importance of Applying Load Quickly + (20:25:14, 23 December 2024)
- ML20002D326 + (20:25:15, 23 December 2024)
- ML20002D325 + (20:25:16, 23 December 2024)
- 05000368/LER-1980-093, Forwards LER 80-093/03L-0 + (20:25:17, 23 December 2024)
- ML20002D320 + (20:25:18, 23 December 2024)
- ML20002D322 + (20:25:18, 23 December 2024)
- ML20002D319 + (20:25:19, 23 December 2024)
- 05000272/LER-1980-068, Forwards LER 80-068/03L-0 + (20:25:20, 23 December 2024)
- ML20002D317 + (20:25:22, 23 December 2024)
- 05000339/LER-1980-103-03, /03L-0:on 801220,refueling Water Storage Tank Level Transmitters LT-QS-200B,C & D Froze.Caused by Cold Outside Temp Along W/Improperly Adjusted Setpoint Pots on Heat Tracing Circuits.Transmitters Thawed & Pots Adjusted + (20:25:24, 23 December 2024)
- 05000339/LER-1980-103, Forwards LER 80-103/03L-0 + (20:25:25, 23 December 2024)
- 05000338/LER-1980-106-03, /03L-0:on 801221,fire Door S94-6 Found to Be Nonfunctional.Caused by Hole in Door & Misaligned Hardware. Cover Plate Installed Over Hole & Hardware Adjusted + (20:25:27, 23 December 2024)
- 05000338/LER-1980-106, Forwards LER 80-106/03L-0 + (20:25:28, 23 December 2024)
- 05000339/LER-1980-102-03, /03L-0:on 801218,axial Flux Difference Deviated Above Target.Caused by Increasing Reactor Power During Startup W/Effects of Xenon Burnout.Rods Borated Out to Restore Axial Flux Difference to within Target Band + (20:25:30, 23 December 2024)
- 05000339/LER-1980-102, Forwards LER 80-102/03L-0 + (20:25:32, 23 December 2024)
- ML20002D306 + (20:25:34, 23 December 2024)
- B10142, Application to Amend License DPR-21,revising Fire Protection Section 3.F to Permit Util to Proceed W/Mods Identified in NRC 780926 Fire Protection Safety Evaluation.Mods Will Be Completed Prior to Return to Power Following 1980 Outage + (20:25:35, 23 December 2024)
- ML20002D304 + (20:25:36, 23 December 2024)
- ML20002D303 + (20:25:37, 23 December 2024)
- ML20002D301 + (20:25:37, 23 December 2024)
- ML20002D300 + (20:25:38, 23 December 2024)
- ML20002D299 + (20:25:38, 23 December 2024)
- ML20002D297 + (20:25:39, 23 December 2024)
- 05000312/LER-1980-049-03, /03L-0:on 801219,during Performance of Sp 206.03B, B Diesel Generator Failed to Start.Cause Not Stated.Unit Declared Operable 801222 After Passing Applicable Surveillance Test + (20:25:41, 23 December 2024)
- ML20002D295 + (20:25:42, 23 December 2024)
- ML20002D294 + (20:25:43, 23 December 2024)
- ML20002D292 + (20:25:44, 23 December 2024)
- 05000278/LER-1980-030-03, /03L-0:on 801214,backup Nitrogen Bottle Supply to Inboard Containment Isolation Valve AO-3506 Found Valved Out of Svc.Pressure Regulation Adjustment Screw Missing.Cause Unknown.Backup Nitrogen Supply Restored + (20:25:45, 23 December 2024)
- ML20002D290 + (20:25:46, 23 December 2024)
- ML20002D289 + (20:25:47, 23 December 2024)
- ML20002D288 + (20:25:47, 23 December 2024)
- ML20002D287 + (20:25:48, 23 December 2024)
- TXX-3266, Interim Deficiency Rept Re Unauthorized Field Mods to Hilti-Kwik Concrete Anchor Bolts,Initially Reported 801001. Bolts Have Not Been Modified in Unauthorized Manner. Follow-up Rept Will Be Submitted by 810417 + (20:25:48, 23 December 2024)