Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000458/LER-1989-045, :on 891212,Div I Standby Svc Water Pumps Received Automatic Start Signal Due to Spurious Low Svc Water Pressure Signal When Normal Svc Water Pump Secured. Signal Cleared & Sys Restored to Normal Lineup + (12:56:38, 23 December 2024)
- ML20005G165 + (12:56:40, 23 December 2024)
- 05000458/LER-1989-044, :on 891211,unplanned ESF Actuation Occurred, Resulting in Isolation of Rcic.Caused by Technician Failing to Perform Steps of Surveillance Test Procedure in Sequence.Div II Isolation Signal Reset + (12:56:41, 23 December 2024)
- ML20005G163 + (12:56:43, 23 December 2024)
- ML20005G162 + (12:56:44, 23 December 2024)
- ML20005G161 + (12:56:45, 23 December 2024)
- ML20005G157 + (12:56:46, 23 December 2024)
- NLS9000008, Application for Amend to License DPR-46,consisting of Proposed Change 85 to Tech Specs Removing motor-operated Bypass Valves & Air Operators from Testable Check Valves in Rhr,Core Spray,Rcic & HPCI Sys + (12:56:47, 23 December 2024)
- ML20005G153 + (12:56:50, 23 December 2024)
- RBG-32073, Forwards Rev to Informational Rept Re Test of thermo-lag Fire Barrier Matl Transmitted on 891220.Rept Provides Info Re Ongoing Investigations of Issue & Interim Corrective Actions Taken + (12:56:55, 23 December 2024)
- ML20005G148 + (12:56:57, 23 December 2024)
- BSEP-90-0006, Special Rept 1-SR-90-001:on 900103,technician Opened Cabinet Door to 4,160 Volt Contactor Cabinet for motor-driven Fire Pump,Resulting in Operating Fire Pump Trip.Technician Immediately Closed Cabinet Door.Power Supplies Reenergized + (12:56:58, 23 December 2024)
- ML20005G145 + (12:57:00, 23 December 2024)
- ML20005G144 + (12:57:01, 23 December 2024)
- ML20005G143 + (12:57:02, 23 December 2024)
- ML20005G142 + (12:57:03, 23 December 2024)
- ML20005G141 + (12:57:04, 23 December 2024)
- ML20005G138 + (12:57:05, 23 December 2024)
- ML20005G140 + (12:57:05, 23 December 2024)
- ML20005G137 + (12:57:06, 23 December 2024)
- ML20005G135 + (12:57:08, 23 December 2024)
- ML20005G136 + (12:57:08, 23 December 2024)
- ML20005G133 + (12:57:09, 23 December 2024)
- ML20005G131 + (12:57:10, 23 December 2024)
- ML20005G129 + (12:57:11, 23 December 2024)
- ML20005G128 + (12:57:12, 23 December 2024)
- PNO-V-90-002, on 900107,earthquake of 4.7 on Richter Scale Occurred 40 Miles Northwest of Fairbanks,Al.Region V Notified by FEMA on 900107.No Damage Reported + (12:57:17, 23 December 2024)
- ML20005G124 + (12:57:18, 23 December 2024)
- ML20005G125 + (12:57:18, 23 December 2024)
- ML20005G122 + (12:57:19, 23 December 2024)
- ML20005G121 + (12:57:20, 23 December 2024)
- ML20005G119 + (12:57:21, 23 December 2024)
- ML20005G118 + (12:57:22, 23 December 2024)
- IR 05000445/1989088 + (12:57:28, 23 December 2024)
- ML20005G115 + (12:57:29, 23 December 2024)
- ML20005G113 + (12:57:30, 23 December 2024)
- ELV-01211, Responds to NRC 891206 Transmittal of SALP & Discussion at 891214 Meeting W/Nrc at Site.Disagrees W/Nrc Evaluation as Stated in SALP Ltr & Transmittal Ltr Re Overall Level of Performance During SALP Period.Reasons Listed + (12:57:32, 23 December 2024)
- ML20005G112 + (12:57:32, 23 December 2024)
- IR 05000361/1989032 + (12:57:35, 23 December 2024)
- ML20005G107 + (12:57:37, 23 December 2024)
- ML20005G106 + (12:57:38, 23 December 2024)
- ML20005G104 + (12:57:39, 23 December 2024)
- AECM-89-0231, Forwards Comments on SALP Rept for Period May 1988 - Sept 1989 + (12:57:40, 23 December 2024)
- 05000293/LER-1989-038, :on 891208,unplanned Automatic Reactor Protection Sys Scram Signal & Reactor Scram Occurred.Caused by False Low Reactor Vessel Water Level Signal.Local Level Indicators Satisfactorily Calibr + (12:57:42, 23 December 2024)
- ML20005G096 + (12:57:44, 23 December 2024)
- ML20005G095 + (12:57:45, 23 December 2024)
- ML20005G092 + (12:57:46, 23 December 2024)
- ML20005G091 + (12:57:47, 23 December 2024)
- ML20005G090 + (12:57:48, 23 December 2024)
- ML20005G088 + (12:57:49, 23 December 2024)
- 0CAN019008, Discusses Util long-term Resolution to Hydrogen Monitoring Capabilities & Requests Relief from NUREG-0737,Item II.F.1. Util Completed Design Changes to Provide fail-open Solenoid Operated Valve in Place of motor-operated Valve + (12:57:53, 23 December 2024)