- ML20009E941 + (13:28:38, 21 December 2024)
- ML20009E938 + (13:28:39, 21 December 2024)
- 05000336/LER-1981-025-03, /03L-0:on 810615,span Gas Voltage on Hydrogen Analyzer B Found Out of Spec.Caused by Instrument Drift Due to High Temp within Analyzer Cabinets.Temp Control Switch Reset + (13:28:41, 21 December 2024)
- ML20009E934 + (13:28:42, 21 December 2024)
- ML20009E927 + (13:28:43, 21 December 2024)
- ML20009E924 + (13:28:43, 21 December 2024)
- 05000366/LER-1981-058-03, /03L-0:on 810622,during steady-state Operation at 2,194 Mw,Reactor Bldg to Torus Vacuum Breaker Isolation Valve 2T48-F310 Failed Open.Cause Attributed to Torus Differential Pressure Switch Setpoint Drift.Switch Recalibr + (13:28:44, 21 December 2024)
- 05000336/LER-1981-025, Forwards LER 81-025/03L-0 + (13:28:46, 21 December 2024)
- ML20009E917 + (13:28:48, 21 December 2024)
- ML20009E913 + (13:28:49, 21 December 2024)
- ML20009E914 + (13:28:49, 21 December 2024)
- ML20009E912 + (13:28:50, 21 December 2024)
- ML20009E911 + (13:28:50, 21 December 2024)
- 05000366/LER-1981-058, Forwards LER 81-058/03L-0 + (13:28:53, 21 December 2024)
- 05000339/LER-1981-050-03, /03L-0:on 810619 & 20,during RCS Cooldown to Cold Shutdown Conditions,Individual Rod Position Indication B Shutdown Bank Rod G-7 & J-9 Deviated from Group Demand Position.Caused by Instrument Drift + (13:28:55, 21 December 2024)
- ML20009E906 + (13:28:56, 21 December 2024)
- ML20009E902 + (13:28:57, 21 December 2024)
- ML20009E901 + (13:28:58, 21 December 2024)
- ML20009E900 + (13:28:59, 21 December 2024)
- ML20009E899 + (13:28:59, 21 December 2024)
- 05000339/LER-1981-050, Forwards LER 81-050/03L-0 + (13:29:01, 21 December 2024)
- ML20009E896 + (13:29:02, 21 December 2024)
- ML20009E895 + (13:29:02, 21 December 2024)
- ML20009E892 + (13:29:05, 21 December 2024)
- 1CAN078105, Advises That Licensee Response to NRC 810109 Request for Addl Info Re Asymmetric LOCA Loads,Has Been Provided by B&W + (13:29:06, 21 December 2024)
- ML20009E890 + (13:29:07, 21 December 2024)
- 05000327/LER-1981-073-03, /03L-0:on 810629,w/unit in Mode 1 at 100% RTP, Ice Condenser Intermediate Deck Doors Found to Be Frosted. Caused by Moisture Dripping from Upper Deck Doors,Due to Damaged Tape Seals.Frost Was Removed by 810630 + (13:29:09, 21 December 2024)
- ML20009E888 + (13:29:09, 21 December 2024)
- ML20009E884 + (13:29:12, 21 December 2024)
- ML20009E882 + (13:29:12, 21 December 2024)
- 05000327/LER-1981-073, Forwards LER 81-073/03L-0 + (13:29:17, 21 December 2024)
- ML20009E878 + (13:29:18, 21 December 2024)
- ML20009E875 + (13:29:19, 21 December 2024)
- 0CAN078107, Responds to Generic Ltr 81-04 Re Emergency Procedures & Training for Station Blackout Events.Sufficient Time Is Available to Restore Power Following Station Blackout. Capability to Mitigate Effects of Postulated Event Is Good + (13:29:20, 21 December 2024)
- 05000334/LER-1981-062-03, /03L-0:on 810619,auxiliary Flow Path to Steam Generator 1A Was Isolated.Caused by Maint on Leaking Feed Flow Transmitter Instrument Line Penetration Into Auxiliary Feed Flow Header A.Piping Refabricated + (13:29:22, 21 December 2024)
- ML20009E872 + (13:29:23, 21 December 2024)
- ML20009E871 + (13:29:24, 21 December 2024)
- ML20009E870 + (13:29:25, 21 December 2024)
- ML20009E869 + (13:29:25, 21 December 2024)
- 05000334/LER-1981-062, Forwards LER 81-062/03L-0 + (13:29:26, 21 December 2024)
- ML20009E866 + (13:29:27, 21 December 2024)
- ML20009E864 + (13:29:30, 21 December 2024)
- ML20009E860 + (13:29:30, 21 December 2024)
- 05000302/LER-1981-038-04, /04T-0:on 810605,first Half 1981 Green Leafy Vegatable Sample for Station C48 Had 83 Picocuries Per Kg of Sr-90,exceeding ETS by 10 Times.Cause Undetermined.Resample Being Performed + (13:29:32, 21 December 2024)
- ML20009E857 + (13:29:33, 21 December 2024)
- ML20009E856 + (13:29:34, 21 December 2024)
- ML20009E854 + (13:29:35, 21 December 2024)
- 05000302/LER-1981-038, Forwards LER 81-038/04T-0 + (13:29:36, 21 December 2024)
- 05000311/LER-1981-044-04, /04T:on 810707,contamination of Onsite Storage Area Ten Times Normal Background Reading Discovered Where Old Spent Fuel Storage Racks Had Been Stored.Caused by Rinsing of Racks & High Ambient Temps + (13:29:38, 21 December 2024)
- 05000245/LER-1981-015-03, /03L-0:on 810617,failure to Perform Routine Primary Containment Personnel Airlock Door Leak Rate Test Identified.Cause Attributed to Personnel Oversight.Test Completed & Added to Shift Surveillance Schedule Log + (13:29:40, 21 December 2024)
- ML20009E848 + (13:29:41, 21 December 2024)