- 05000369/LER-1981-070, Forwards LER 81-070/03L-0.Detailed Event Analysis Encl + (13:17:14, 21 December 2024)
- 05000369/LER-1981-083, Forwards LER 81-083/01T-0.Detailed Event Analysis Encl + (13:17:17, 21 December 2024)
- 05000280/LER-1981-035-03, Fuel Oil Transfer Pump 1B Suction Valve 1-EE-14 Found Closed.Caused by Personnel Error.Valve Opened + (13:17:19, 21 December 2024)
- ML20009F716 + (13:17:21, 21 December 2024)
- ML20009F715 + (13:17:21, 21 December 2024)
- 05000280/LER-1981-015-03, /03L-0:on 810603,spent Fuel Pit Overflowed Into New Fuel Handling Area & Outside to Storm Drain.Caused by Leaking Diaphragm Valve & Defeated High Level Alarm Annunciator.Valve Repaired + (13:17:25, 21 December 2024)
- 05000366/LER-1981-067, Forwards LER 81-067/03L-0 + (13:17:28, 21 December 2024)
- 05000280/LER-1981-015, Forwards LER 81-015/03L-0,updated LER 81-035/03X-1 & Corrected LER 81-036/03L-0 + (13:17:30, 21 December 2024)
- 05000339/LER-1981-047-03, /03L-0:on 810609,solid State Protection Sys Train B Stop Valve Generator Trip Logic Failed to Meet Acceptance Criteria.Caused by Faulty Universal Card A404. Card Replaced & Logic Channel Returned to Svc + (13:17:34, 21 December 2024)
- ML20009F707 + (13:17:35, 21 December 2024)
- 05000339/LER-1981-047, Forwards LER 81-047/03L-0 + (13:17:37, 21 December 2024)
- 05000366/LER-1981-061-03, /03L-0:on 810624,hi-lo Flow Alarm Received for Reactor Bldg Vent Radiation Monitor Sys.Caused by Tripping of Sample Pumps a & B Due to Overload Protection Tripping. Vanes in Pump a Replaced.Pump B Overload Reset + (13:17:44, 21 December 2024)
- 05000327/LER-1981-065-03, /03L-0:on 810603,turbine Sump Discharge Monitor O-RM-90-212 Declared Inoperable.Caused by Broken Pump/Motor Coupling.Coupling Replaced & Monitor Returned to Svc + (13:17:45, 21 December 2024)
- ML20009F700 + (13:17:48, 21 December 2024)
- 05000369/LER-1981-076-03, /03L-0:on 810502,alarm Annunciated for Noble Gas Activity monitor,EMF-33,indicating Loss of Sample Flow During Initial Fuel Loading.Caused by Bolts Insufficiently Tightened to Secure Seals During Monitor Maint + (13:17:52, 21 December 2024)
- ML20009F697 + (13:17:52, 21 December 2024)
- ML20009F695 + (13:17:54, 21 December 2024)
- 05000369/LER-1981-076, Forwards LER 81-076/03L-0.Detailed Event Analysis Encl + (13:17:55, 21 December 2024)
- 05000369/LER-1981-072-03, /03L-0:on 810427,RHR Sys Discovered Isolated from RCS During Mod of Train a Solid State Protection Sys to Include Reactor on Turbine Trip.Caused by de-energized Relay in Logic,Closing Isolation Valve + (13:17:57, 21 December 2024)
- 05000327/LER-1981-065, Forwards LER 81-065/03L-0 + (13:17:58, 21 December 2024)
- ML20009F686 + (13:17:59, 21 December 2024)
- 05000366/LER-1981-061, Forwards LER 81-061/03L-0 + (13:18:02, 21 December 2024)
- 05000369/LER-1981-072, Forwards LER 81-072/03L-0.Detailed Event Analysis Encl + (13:18:06, 21 December 2024)
- ML20009F680 + (13:18:09, 21 December 2024)
- 05000302/LER-1981-039-03, /03L-0:on 810630,control Rod Units 1 & 2 Rendered Inoperable During Maint on House Svcs Transformer.Caused by Personnel Shorting 4,160-volt Bus Supplying Startup Transformer While Checking Energized Sections + (13:18:12, 21 December 2024)
- 05000366/LER-1981-065-03, /03L-0:on 810626,hydrogen-oxygen Analyzer Found Inoperable.Caused by Partially Clogged Gas Flow Regulators. Gas Flow Regulators Cleaned & Readjusted.Analyzer Recalibr + (13:18:14, 21 December 2024)
- ML20009F675 + (13:18:15, 21 December 2024)
- ML20009F674 + (13:18:15, 21 December 2024)
- 05000302/LER-1981-039, Forwards LER 81-039/03L-0 + (13:18:16, 21 December 2024)
- ML20009F671 + (13:18:17, 21 December 2024)
- ML20009F669 + (13:18:18, 21 December 2024)
- 05000260/LER-1981-034-03, /03L-0:on 810630,RHR Svc Water Pumps B2,D-1 & D-2 Were Not in Svc.Caused by Removing B2 from Svc to Change Motor Oil & Tagging Closed Crosstie Valve to Unit 1, FCV-1-74-100.Oil Changed + (13:18:19, 21 December 2024)
- 05000260/LER-1981-031-03, /03L-0:on 810701,RHR Pump Room Cooler 3-A Developed Water Leak.Caused by Broken Silfos Joint on 1/4-inch Vent Line.Joint Resoldered + (13:18:20, 21 December 2024)
- ML20009F666 + (13:18:22, 21 December 2024)
- 05000339/LER-1981-054-03, /03L-0:on 810629,train J of Onsite Ac Power Sys Discovered Not Tested Per Tech Specs Since 790316.Caused by Mistaken Impression That Both Buses Were Retested on 800331.Emergency Bus J Tested on 800331 + (13:18:24, 21 December 2024)
- 05000260/LER-1981-034, Forwards LER 81-034/03L-0 + (13:18:25, 21 December 2024)
- 05000366/LER-1981-065, Forwards LER 81-065/03L-0 + (13:18:26, 21 December 2024)
- ML20009F659 + (13:18:27, 21 December 2024)
- ML20009F658 + (13:18:29, 21 December 2024)
- 05000260/LER-1981-031, Forwards LER 81-031/03L-0 + (13:18:30, 21 December 2024)
- 05000348/LER-1981-045-03, /03L-0:on 810613,train Svc Water Loop a Declared Inoperable.Caused by Inoperable Emergency Recirculation Valve Due to Blown Control Circuit Fuse.Fuse Replaced,Valve Tested & Loop Returned to Svc on 810613 + (13:18:31, 21 December 2024)
- 05000339/LER-1981-054, Forwards LER 81-054/03L-0 + (13:18:33, 21 December 2024)
- ML20009F652 + (13:18:34, 21 December 2024)
- ML20009F650 + (13:18:35, 21 December 2024)
- 05000369/LER-1981-082-03, /03L-0:on 810504-22,fire Detection Sys Found Inoperable.Caused by Const in Area.Fire Watches & Patrols Established + (13:18:36, 21 December 2024)
- 05000335/LER-1981-027-03, /03L-0:on 810519,while Cleaning Condenser Water Boxes,Control Element Assembly 65 Dropped While Being Inserted.Cause Unknown.Assembly Returned to Group Position + (13:18:38, 21 December 2024)
- 05000348/LER-1981-044-03, /03L-0:on 810610,diesel Generator 1C Declared Inoperable During Test FNP-1-STP-28.1.Caused by Overvoltage Condition Due to Damaged Voltage Regulator Circuitry Resulting from Failed Engine Running Relay + (13:18:39, 21 December 2024)
- 05000369/LER-1981-095-03, /03L-0:on 810606,flow Rate Measurement Instrumentation on Waste Monitor Tank a Declared Inoperable During Attempted Liquid Water Release.Caused by Supply Air Isolation Valve to Transmitter Left Closed Following Maint + (13:18:40, 21 December 2024)
- 05000321/LER-1981-057-03, /03L-0:on 810611,temporary Change to HNP-1-6907 (Reactor Core Isolation Cooling Pump Suction Hydro) Found Not Approved by Mgt within Reguired Time.Caused by Personnel Failure to Maintain Adequate Control Over Procedure + (13:18:42, 21 December 2024)
- 05000369/LER-1981-082, Forwards LER 81-082/03L-0 + (13:18:43, 21 December 2024)
- ML20009F640 + (13:18:44, 21 December 2024)
- 05000335/LER-1981-027, Forwards LER 81-027/03L-0 + (13:18:45, 21 December 2024)