ML20009F697

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Inconsistent Establishment of Insp Program,Initially Reported 810324.Program of Indentification/Evaluation of Const Activities Begun to Correct Deficiency.Next Rept Expected by 811215
ML20009F697
Person / Time
Site: Hartsville, Phipps Bend  
Issue date: 06/09/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8107310418
Download: ML20009F697 (1)


Text

_

OFFICIAL COPY TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TINNESSEE 37408 -

c'

~-

400 Chestnut Street Tower II June 9, 1981

,g gg pI 00 HTRD-50-518/81-12, -519, -520,-521/81-10 PBRD-50-553/81-13, -554/81-08

/ q,

((,h7 Mr. Jame.s P. O'Reilly, Director Office of Inspection and Enforcement 7 g,g i) L)

]

U.S. Nuclear Regulatory Commission Q

Region II - Suite 3100 JUL ' 01981, 101 Marietta Street

b. ms..ww#

?

Atlanta, Georgia 30303 4

xg

Dear Mr. O'Reilly:

HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - REPORTABLE DEFICIENCY -

INCONSISTENT ESTABLISHMENT OF INSPECTION PROGRAM -

HTRD-50-518/81-12, -519, -520 -521/81 PBRD-50-553/81-13.

-554/81-08 The subject deficiencies were initially reported to NRC-0IE, Region II, Inspector P. A. Taylor on March 24, 1981, as NCR's HTANEB81-01 and PBNNEB81-01. The first interim report was submitted on April 23, 1981.

In compliance with paragraph 50.55(e) of 10 CFR Part 50, this letter constitutes the second interim report on the subject deficiency.

TVA has begun a program at its Watts Bar Nuclear Plant by wnich this NCR will be resolved. The program serves as an ide6tification/ evaluation of construction activities, inspections, requirements, and associated procedures. The results of this program will then be evaluated and any changes or additions necessary to address design considerations will be incorporated. The applicability of this program to Hartsville and Phipps Bend will be addressed following completion of the Watts Bar program.

Because of the extensive nature of the program described above, TVA will submit another report on or oefore December 15, 1981. This deficiency has also been reported for TVA's.Sequoyah unit 2, Watts Bar, Bellefonte, and Yellow Creek Nuclear Plants.

If you have any questions, please call Jim Domer at FTS 857-2014 Very truly yours, TENNESSEE VALLEY AUTHORITY b.M b Lj DS K, L. M. Mills, Manager

(

Nuclear Regulation and Safety

(

cc:

Mr. Victor Stello, Jr., Director Office of Inspection and Enforement l

U.S. Nuclear Regulatory Commission Af I

Washington, DC 20555 6

8107310418 810609 PDR ADOCK 05000S18 S

PDR

_____Aarmi amnrtunitxC_..__ _

-,.