- 05000369/LER-1981-079-03, /03L-0:on 810508,during Fuel Loading,Water Found in Sample Line for Noble Gas Activity Monitor.Caused by Improperly Designed Loop Seal on Sample Line.Monitor Repaired & Mods Being Made to Correct Deficiency + (13:07:50, 21 December 2024)
- ML20009G220 + (13:07:51, 21 December 2024)
- ML20009G218 + (13:07:52, 21 December 2024)
- 05000277/LER-1981-035-01, /01T-0:on 810622,leakage Through Several Points in Recombiner Sys Resulted in 3-h Release Through Unit 3 Reactor Bldg Vent.Caused by Loss of Negative Pressure. Leak Points Isolated by Valve Closure or Pipe Capping + (13:07:53, 21 December 2024)
- 05000369/LER-1981-079, Forwards LER 81-079/03L-0.Detailed Event Analysis Encl + (13:07:55, 21 December 2024)
- 05000369/LER-1981-075-03, /03L-0:on 810501,during Routine Surveillance, Broken Motor Mounts Discovered on Control Room Outside Air Filter Makeup Fan.Caused by Metal Fatigue.Mounts Repaired & Sys Returned to Operability + (13:07:57, 21 December 2024)
- ML20009G213 + (13:07:58, 21 December 2024)
- 05000277/LER-1981-035, Forwards LER 81-035/01T-0.Detailed Event Analysis Encl + (13:07:59, 21 December 2024)
- 05000369/LER-1981-075, Forwards LER 81-075/03L-0.Detailed Event Analysis Encl + (13:08:01, 21 December 2024)
- 05000335/LER-1981-028-03, /03L-0:on 810522,during Normal Operations,One of Two Chlorine Detectors in North Control Room Air Intake Failed.Caused by Clogging of Wick.Wick Replaced + (13:08:03, 21 December 2024)
- ML20009G204 + (13:08:04, 21 December 2024)
- 05000338/LER-1981-041-99, /99T-0:on 810609,annunciation for 16 Hz east-west Containment Mat Response Spectrum Recorder Illuminated & Could Not Be Reset.Cause Unknown.Recorder Will Be Replaced or Repaired During Next Cold Shutdown + (13:08:05, 21 December 2024)
- 05000335/LER-1981-028, Forwards LER 81-028/03L-0 + (13:08:07, 21 December 2024)
- 05000260/LER-1980-058-03, During Performance of SI 4.1.A-8,scram Discharge Instrument Vol Tank Level Switch 2-LS-85-45F Failed Per IE Bulletin 80-14.Caused by Robertshaw Level Switch Inoperability + (13:08:08, 21 December 2024)
- 05000338/LER-1981-041, Forwards LER 81-041/99T-0 + (13:08:10, 21 December 2024)
- ML20009G197 + (13:08:11, 21 December 2024)
- 05000369/LER-1981-061-03, /03L-0:on 810420,primary Containment Integrity Lost.Outer Door of Lower Personnel Air Lock Open & Inner Door Closed But Not Sealed.Outer Door Open Due to Faulty Limit Switch & Inner Door Due to Too Quick Closing + (13:08:13, 21 December 2024)
- ML20009G195 + (13:08:14, 21 December 2024)
- ML20009G194 + (13:08:15, 21 December 2024)
- ML20009G193 + (13:08:16, 21 December 2024)
- 05000339/LER-1981-049-03, /03L-0:on 810612,during Periodic Test,Casing Cooling Pump 2-RS-P-3A Tripped.Caused by Power Supply Breaker Opening on Overcurrent Due to Excessive Load Created by Misalignment of Bearing Holders & Caps.Bearings Aligned + (13:08:18, 21 December 2024)
- 05000369/LER-1981-061, Forwards LER 81-061/03L-0.Detailed Event Analysis Encl + (13:08:20, 21 December 2024)
- ML20009G187 + (13:08:23, 21 December 2024)
- 05000260/LER-1980-058, Forwards Updated LER 80-058/03X-1 + (13:08:24, 21 December 2024)
- ML20009G184 + (13:08:25, 21 December 2024)
- 05000369/LER-1981-073-03, /03L-0:on 810428,RHR Isolation Valve 1ND1B Failed to Reopen Following Stroke Test.Cause Not Determined.Limit Switches Adjusted & Functioned Properly When Cycled + (13:08:27, 21 December 2024)
- ML20009G180 + (13:08:30, 21 December 2024)
- 05000339/LER-1981-049, Forwards LER 81-049/03L-0 + (13:08:31, 21 December 2024)
- 05000324/LER-1981-052-03, /03L-0:on 810609,reactor Recirculation Pump Motor Generator 2A Tripped During Unit Load Changes.Cause Unknown. Dirty Electrical Contacts Found in Field Breaker Closure Circuitry Cleaned + (13:08:33, 21 December 2024)
- 05000364/LER-1981-021-03, /03L-0:on 810606,overtemp-delta Temp Instrumentation Loop Trip Setpoint Failed to Meet Tolerance Requirements.Caused by Gain Potentiometer Being Out of Adjustment.Potentiometer Adjusted + (13:08:34, 21 December 2024)
- 05000335/LER-1981-029-03, /03L-0:on 810528,while Performing Engineered Safety Feature Channel Functional Test,Steam Generator Pressure Channel Mc Setpoint Was Less than Tech Specs. Cause of Drift Undetermined.Setpoint Adjusted + (13:08:36, 21 December 2024)
- ML20009G173 + (13:08:38, 21 December 2024)
- 05000369/LER-1981-073, Forwards LER 81-073/03L-0.Detailed Event Analysis Encl + (13:08:39, 21 December 2024)
- 05000324/LER-1981-059-01, /01T-0:on 810629,valve Lineup for Loop a of RHR in Standby Readiness Was Incorrect.Caused by Control Operator Commencing Plant Startup W/O Knowing That Valve F020A Was Open.Rods Inserted & Sys Lineup Verified + (13:08:41, 21 December 2024)
- 05000364/LER-1981-021, Forwards LER 81-021/03L-0 + (13:08:42, 21 December 2024)
- 05000324/LER-1981-052, Forwards LER 81-052/03L-0 + (13:08:47, 21 December 2024)
- 05000260/LER-1981-032-03, /03L-0:on 810702,equipment Air Lock Door 238 Was Not Properly Latched Before Opposite Door Was Opened.Caused by Personnel Error.Personnel Instructed in Correct Operation of Doors + (13:08:49, 21 December 2024)
- 05000369/LER-1981-055-03, /03L-0:on 810416,cold Leg Injection Accumulator Declared Inoperable Due to High Level Alarm.Caused by Cold Leg Accumulator Discharge Check Valves Leaking.Valves to Be Repaired & Retested + (13:08:51, 21 December 2024)
- ML20009G163 + (13:08:52, 21 December 2024)
- 05000335/LER-1981-029, Forwards LER 81-029/03L-0 + (13:08:53, 21 December 2024)
- 05000369/LER-1981-055, Forwards LER 81-055/03L-0.Detailed Event Analysis Encl + (13:08:57, 21 December 2024)
- 05000324/LER-1981-059, Forwards LER 81-059/01T-0 + (13:08:58, 21 December 2024)
- IR 05000333/1981014 + (13:09:01, 21 December 2024)
- 05000260/LER-1981-032, Forwards LER 81-032/03L-0 + (13:09:03, 21 December 2024)
- 05000335/LER-1981-032-03, /03L-0:on 810624,plant Personnel Determined Periodic Test of AB Battery Charger Had Not Been Performed. Caused by Interpreting Tech Specs Precisely.Test Satisfactorily Performed + (13:09:05, 21 December 2024)
- ML20009G151 + (13:09:06, 21 December 2024)
- ML20009G149 + (13:09:07, 21 December 2024)
- 05000335/LER-1981-032, Forwards LER 81-032/03L-0 + (13:09:08, 21 December 2024)
- ML20009G145 + (13:09:09, 21 December 2024)
- ML20009G144 + (13:09:10, 21 December 2024)
- ML20009G143 + (13:09:10, 21 December 2024)