Text

,mn~~nmmwn w=nmama NS SAVANNAH I*'"'

June 10,1931 RADIATION MONITORING REPORT 1

[

PROJECT:

Nuclear Ship SAVANNAH LOCATION:

Charleston, SC CCCKET NO:

50-238 LICENSE NO:

NRC No. NS-1 I

LICENSEE:

Maritime Admini;tration 1

A t t. u. request of the U.S. Nuclear Pegula tory Comisr ien, a second radia tion survey was performed aboard the N/S SAVANNAH utilizing e nicroR survey instrument.

This survey was perforced by Emory Willian.s, Radiation Safety Of ficer representing the f>.aritime Administration ar.d was conducted en Wednesd3y June 10, 1931.

l Instrumentation used for the survey consisted of an Eberline PFM-5N Couht Rate Meter with an Eberline SPA-3 Scdium Iodide Scintillation Detector Readings were obtained in counts per minute and were converted into micreR/hr f or reportirig pur-poses.

The radiation survey conducted on June 10, 1381 was done to confirm a similar survey conducted on flarch 23, 1981. The June survey wc,rore extensive since all of the staterocus and compartments were opened and could be entered for radiation men-itoring.

In all, over 130 staterooms, compartments, and arras were monitored durinq the June survey, whereas less than~S0 micro" readings could t'e made during " arch.

I Defining the background level for the N/S Sf. VAN"AH was determined by taking rad-iation readings topside of the vessel at the for thest points fron the Reactor Com-partment.

This method had to be used since the background readings on the concrete dock and on the land area near the vessel where higher '.han the topside readings en the vessel.

The results rf the survey are shown an the following peges.

Background Readings:

l Bow of ship at ship's bell, weatherdeck.....

1.3 nicroP/hr i

S tern of ship a t flag sta f f, weatherdeck...............

1.3 Flying Bridge, wea therdeck.................

1.s 1

L i

AVEPAGE BACKGROUND......

1.33 l

l

&c6MW Emcry F. Williams Radiation Safety Officer 8108030400 g hg PDR ADOCK o PDR P

1 I

NS SAVANNAH l

I r

Date aune 10, 1981 RADIATION MONITORING REPORT Area Surveyed Direct Reading Reading, less microR/hr 1.3 uR/hr Bkgn NAVIGATION BRIDGE DECK In Pilot House at helm--------------------------------

3.0 ------------- 1.7 t

B ri dg e W i n g, P o r t S i d e ------- ----------- -- - - ------ ---- 2. 6 - - -- --- -- - - -- 1. 3 B r i dg e Wi ng, S ta rboa rd S i d e-------------


2. 6 ------------- 1. 3 Chart Room, Port Side---------------------------------

2.6 ------------- 1.3 Radio Room, Starboard Side---------------------------- 2.8 ------------- 1.5 Eme rg en cy Gen e ra to r Room----------- ----- - - ------ ----- - 1. 8 - - - - - - ---- --- 0. 5 Gyro / Radar Room---------------------------------------

2.7 ------------- 1.4 l

State Rooms, Stcrboard Side (highest reading)--------- ?.8 ------------- 1.5 i

BOAT DECK 1

Chief Engineers Office-State Rocm, Port Side---------

4.5 ------------- 3.2 Captain's Office-State Room, Starboard Side----------

4.8 ------------- 3.5

~

Chief Mate's Office-State Room, Starboard Side-------

4.6 ------------- 3.3 Two Forward State Rooms (highest reading)------------

3.9 ------------- 2.6 State Rooms, Port Side (highest reading)-------------

3.8 ------------- 2.5 State Roan:, Starboard Side (highest reading)--------

3.C ------------- 2.5 Laundry Room, Port Side------------------------------

3.7 ------------- 2.4 Officer's Lounge, Aft--------------------------------

3.5 ------------- 2.2 PROMENADE DECK C en te r o f Ma i n Loun g e----------------- -------------- - 4.2 ------------- 2.9 Pantry, Port Side-----------------------------~.-----

4.0 ------------- 2.7 Ma i n S t a i r Ca s e, P rom Level -------------------------- 3.9 ------------- 2.6 Cen t e r o f Ve ra nd a - ---- -- ------ --------------- ------- - 3.9 --- --- ----- 2.6 Behind Bar, Veranda----------------------------------

3.9 ----- - ----- 2.6 "A"

DECK S ta te rooms, Forward, Port Si de-----------------

3.4.-------------

2.1 P a n t ry, P o r t S i d e -- -- ---- --. - - -- --- -- - - --- --. - -- --- - 3.3 ------------- 2.0 Chief Purser's Office-State Roon, Port Side----------

3.3 ------------- 2.0 Fi re S ta tion #14, Port Pas sageway--------------------

3.4 ------------- 2.1

=

Barber / Beauty Shop, Starboard Side-------------------

3.5 --------- --- 2.2 State Rooms, Starboard Side (hiscEif. reading)--------

3.3 ------------- 2.0 l

Steward's Office-State Room, Starboard Side----------

3.3--------.---2.0 Fire Station #16, Starboard PassagewayI--------------

2. 4 - - - - - - - - - - - - - 2.1 Do c to r ' s O f f i c e -- -- -- -- - - -- -- -- --- --- - - - --- - - - - -- -- 3.4 ------------- 2.1 O pe ra t i n g R o om- - - - -- - - - -- -- -- -- -- --- -- - - - - - - - - -- -- -- 3.4 ------------- 2.1 Health Physics Lab------------------.----------------

3.4 ---------- -- 2.1 Hospi ta l Wa rd s (highes t reading)---------------------

3.3 ------------- 2.0

_ _ = _ _

~~'

q e

-*e-*?

-wq+ee 9, v-y

  • g e.- aw =,i.

,_-4,,,

e

,w

,,,,-_,.---,v-7,

,,y-p-%---,,.9,-

g._,y q,

m,,4 n*g h A a _ m u r. a v n d i v a m e m - d,. W.< M. M r

,.0

,w f

s NS SAVANNAH IgDate' aune 30, 1983 RADIATION MONITORING REPORT h

i

--"A" DECK (continued)

I Sta te Rooms, Af t, Port Side (highes t reading)--------- 3.0 ------------- 1. 7 l

Sta te Rooms, Af t, Starboard Side (highes t reading)---- 3.1 ------------- 1.8 l

Fi re S ta ti on # 17, Por t Pa s s ageway--------------------- 3. 2 ------------- 1.9 Fi re S ta ti on if 15, S ta rboard Pas s ageway --------------- 3. 3 ------------- 2.0 i

Center of Main Lobby----------.----------------------- 3.3 ------------- 2.0 l

Pu rs er 's O f f ic e, Mi dsh i p, Ma i n Lobby------------------ 3. 2 ------------- 1.0 l

"B" DECK i

l Fi re S ta t ion #20, Port Pas sageway--------------------- 3. 3 ------------- 2.0 S tewa rd 's Me s s a nd Lounge, Por t S ide------------------

3.8 ----------- - 2. 5 s

Dec k C rew Me s s, Po r t S i de ---- -- ---- - - - - - - - - - - - - - - -- - - - 3. 4 - - - - - - - - -- - -- 2.1 j

Engine Crew Mes' Port Side---------------------------

3.1 ------------- 1.8 Cred Lo u n g e, Po r S i de--------- - - ---- - - - - ----- - -- - - - - - 3. 0 -- -- - - - -- - - - - 1. 7 O f f i c e r 's Pan try, Po r t S i de--------------------- ------ 3. 2 ------------- 1. 9 O f f i c er 's Me ss, Po r t Si de----------------------------- 3. 2 - -------- ---- 1. 9 j

F i re S ta ti on #22, Po r t Pa s s a geway--------------------- 3.4 ------------- 2.1

(

Center of Main Dining Room---------------------------- 3.4 ------------- 2.1 Crew Sta te Roams, S tarboard Side (highes t reading)---- 3.4 ------------- 2.1 Officer's State Rooms, Af t, Port Side (highest reading 3.2 ------------- 1.9 Of ficer's State Rooms, Af t, Stb Side (highes t reading) 3.3 ------------- 2.0 i

Conference Room, Aft------


3.0 ------------- 1.7 l

F i re S ta t ion #21, S ta rboa rd Pas s ageway---------------- 3. 4 ------------- 2.1 "C"

DECK Crew Sta te Rooms, Port Side (highest read ing)--------- 2.9 ----------- -- 1.6 Mdin Ships laundry, Port Side---------


- 3.3 ------------- 2.0 Crew Sta te Rooms, Starboard Side (highes t reading)---- 3.1 ------------- 1.8 V i s i to r ' s G a l l e ry, Po rt S i de -------------------------- 3.1 ------- ---- - 1. 8 V i s i te r ' s Ga l l e ry, Fo nva rd------------ --- -- -------- --- 3.1 --- -- ---- -- -- 1. 8 V i g i to r 's Gal l ery, S ta rboa rd S i de--------- ----------- 3. 0 -------- - - -- 1. 7 C0c Room-----------------------------------


2.9 ------------- 1.6 e

RADIATION SAFETY SERVICES P. O. BOX 865 IRMO, S. C. 20063 i

e

~'

O

"'E CJutwe e g,