- ML20010G891 + (10:47:52, 21 December 2024)
- 05000280/LER-1981-041-03, /03L-0:on 810820,PT-27D Revealed That Amp Readings for Heat Tracing Panel 9 Circuit 7A Were Below Acceptance Criteria.Caused by Inadvertent Cutting of Heat Tracing Tape During Cleanup Operations on Boric Acid Flat + (10:47:54, 21 December 2024)
- 05000369/LER-1981-136-01, /01T-0:on 810825,during Test of Turbine Driven Auxiliary Feedwater Pump,Suction Piping Was Overpressurized When Pump Tripped.Caused by Lack of Protection for Auxiliary Feedwater Pump Suction Piping.Damaged Instruments Checke + (10:47:55, 21 December 2024)
- 05000311/LER-1981-085, Forwards LER 81-085/01T-0.Detailed Event Analysis Encl + (10:47:57, 21 December 2024)
- ML20010G885 + (10:48:05, 21 December 2024)
- ML20010G884 + (10:48:11, 21 December 2024)
- 05000369/LER-1981-136, Forwards LER 81-136/01T-0.Detailed Event Analysis Encl + (10:48:12, 21 December 2024)
- ML20010G881 + (10:48:13, 21 December 2024)
- ML20010G879 + (10:48:14, 21 December 2024)
- ML20010G878 + (10:48:19, 21 December 2024)
- AECM-81-282, Final Deficiency Rept Re GH-Bettis Spring Return Actuators, Initially Reported on 801222.Spring Guide Sleeve Shifting Internally Could Prevent Movement of Actuator.Caused by Design Deficiency.Actuators Repaired & Redesigned + (10:48:20, 21 December 2024)
- IR 05000317/1981013 + (10:48:27, 21 December 2024)
- ML20010G874 + (10:48:28, 21 December 2024)
- 05000272/LER-1981-076-01, /01T-0:on 810902,NRC Notified of Svc Water Leaking from Secondary Coil on Containment Fan Coil Unit (Cfcu) 14, Per IE Bulletin 80-24.CFCU Removed from Svc & Declared Inoperable.Caused by Secondary Coil Failure + (10:48:29, 21 December 2024)
- ML20010G871 + (10:48:36, 21 December 2024)
- 05000272/LER-1981-078-01, /01T-0:on 810903,during Surveillance Test,Svc Water Discovered Leaking from Top Secondary Coil 11 on Containment Fan Coil Unit.Caused by Failure of Secondary Coil.Coil Repaired & Returned to Svc + (10:48:37, 21 December 2024)
- ML20010G867 + (10:48:43, 21 December 2024)
- IR 05000219/1981012 + (10:48:49, 21 December 2024)
- ML20010G864 + (10:48:51, 21 December 2024)
- ML20010G862 + (10:48:53, 21 December 2024)
- 05000272/LER-1981-078, Forwards LER 81-078/01T-0.Detailed Event Analysis Encl + (10:48:54, 21 December 2024)
- 05000364/LER-1981-036-03, /03L-0:on 810812,svc Water Dilution Flow Recorder Had Been Inoperable Since 810708 Due to Broken Annubar. Caused by Personnel Not Recognizing This as Limiting Condition of Operation Event + (10:48:56, 21 December 2024)
- ML20010G857 + (10:49:03, 21 December 2024)
- ML20010G854 + (10:49:03, 21 December 2024)
- ML20010G853 + (10:49:04, 21 December 2024)
- 05000272/LER-1981-076, Forwards LER 81-076/01T-0.Detailed Event Analysis Encl + (10:49:05, 21 December 2024)
- ML20010G850 + (10:49:11, 21 December 2024)
- 05000296/LER-1981-041-03, /03L-0:on 810822,during Startup After Tying Turbine Generator Online,First Process Computer P-1 Was Run. Frp/Cmflpd (R) Calculated to Be Less than Tech Spec Setpoint.Caused by Reactor Starting Up + (10:49:14, 21 December 2024)
- ML20010G846 + (10:49:15, 21 December 2024)
- ML20010G844 + (10:49:20, 21 December 2024)
- ML20010G842 + (10:49:26, 21 December 2024)
- 05000364/LER-1981-036, Forwards LER 81-036/03L-0 + (10:49:29, 21 December 2024)
- ML20010G839 + (10:49:36, 21 December 2024)
- 05000296/LER-1981-041, Forwards LER 81-041/03L-0 + (10:49:38, 21 December 2024)
- ML20010G833 + (10:49:45, 21 December 2024)
- 05000348/LER-1981-063-03, /03L-0:on 810812,power Supply Breaker Was Inadvertently Racked Out Rendering R11 & R12 Inoperable. Caused by Personnel Failing to Recognize Both Inboard & Outboard Pumps Operate Through Same Supply Breaker + (10:49:46, 21 December 2024)
- ML20010G831 + (10:49:47, 21 December 2024)
- ML20010G830 + (10:49:53, 21 December 2024)
- ML20010G828 + (10:49:59, 21 December 2024)
- ML20010G829 + (10:49:59, 21 December 2024)
- 2CAN098103, Forwards Proprietary Version of MSS-NA2-P, AR Nuclear One Unit 2 Core Protection Calculator Addressable Constant Determination Methodology. Affidavit Encl.Rept Withheld (Ref 10CFR2.790) + (10:50:00, 21 December 2024)
- ML20010G825 + (10:50:10, 21 December 2024)
- 05000348/LER-1981-062-03, /03L-0:on 810809,train a Penetration Room Filtration Sys Did Not Operate as Required.Caused by Failure of Dc Controller Card.Card Replaced & Calibr + (10:50:11, 21 December 2024)
- IR 05000295/1981015 + (10:50:18, 21 December 2024)
- ML20010G820 + (10:50:18, 21 December 2024)
- ML20010G819 + (10:50:19, 21 December 2024)
- 05000259/LER-1981-045-03, /03L-0:on 810819,found That Start Bus Undervoltage Relays Were Out of Svc for Buses 1A & 1B on 810815 W/Unit in Cold Shutdown.Caused by Personnel Error.Relays Reconnected + (10:50:20, 21 December 2024)
- ML20010G817 + (10:50:27, 21 December 2024)
- 05000296/LER-1981-039-03, /03L-0:on 810817,during Normal Operation,Turbine First Stage Permissive Switch 3-PS-1-81A Found 3% Above Tech Spec Limit.Caused by Barksdale Bourdon Tube Pressure Switch B2T-A-12SS Setpoint Drift.Switch Reset + (10:50:28, 21 December 2024)
- 05000348/LER-1981-061-03, /03L-0:on 810819,diesel Generator 2C Declared Inoperable When Prematurely Removed from Svc for Preventative Maint.Caused by Personnel Tagging Out W/O Final Approval of Operations Personnel + (10:50:31, 21 December 2024)
- 05000259/LER-1981-045, Forwards LER 81-045/03L-0.Detailed Event Analysis Encl + (10:50:33, 21 December 2024)