- 05000260/LER-1981-048-03, /03L-0:on 810921,during Normal Operation,Flow Totalizer FQ-68-5 Drifted High Causing Erroneous Flow Indication to Average Power Range Monitor Channels.Caused by Electronic Failure.Totalizer Replaced + (17:21:37, 20 December 2024)
- 05000325/LER-1981-066, Forwards LER 81-066/03L-0 + (17:21:39, 20 December 2024)
- ML20032A364 + (17:21:41, 20 December 2024)
- IR 05000341/1981015 + (17:21:45, 20 December 2024)
- ML20032A361 + (17:21:47, 20 December 2024)
- ML20032A359 + (17:21:48, 20 December 2024)
- 05000260/LER-1981-048, Forwards LER 81-048/03L-0 + (17:21:49, 20 December 2024)
- ML20032A355 + (17:21:51, 20 December 2024)
- AECM-81-418, Interim Deficiency Rept Re Loose Connections in Wiring, Improper Wire Crimps & Wire Size to Terminal Lug Size Discrepancies Initially Reported 810922.Investigation Underway.Final Rept by 811215 + (17:21:52, 20 December 2024)
- 05000327/LER-1981-118-03, /03L-0:on 810921,radiation Monitors for Containment Ventilation Were Out of Svc Simultaneously. Caused by Tech Spec Misinterpretation.Monitors Removed from Svc for Leak Testing of Containment Isolation Valves + (17:21:55, 20 December 2024)
- ML20032A352 + (17:21:56, 20 December 2024)
- 05000327/LER-1981-118, Forwards LER 81-118/03L-0 + (17:21:57, 20 December 2024)
- ML20032A347 + (17:21:59, 20 December 2024)
- ML20032A346 + (17:22:00, 20 December 2024)
- ML20032A345 + (17:22:01, 20 December 2024)
- ML20032A344 + (17:22:02, 20 December 2024)
- ML20032A343 + (17:22:03, 20 December 2024)
- ML20032A342 + (17:22:04, 20 December 2024)
- ML20032A340 + (17:22:06, 20 December 2024)
- 05000325/LER-1981-068-03, /03L-0:on 811003,control Rod 14-43 Did Not Have Full in or 00 RTGB Position Indication While Fully Inserted.Probably Caused by Defective Rod Position Indication Probe Reed Switch.Investigation Continuing + (17:22:07, 20 December 2024)
- ML20032A338 + (17:22:09, 20 December 2024)
- ML20032A336 + (17:22:10, 20 December 2024)
- 05000325/LER-1981-068, Forwards LER 81-068/03L-0 + (17:22:11, 20 December 2024)
- ML20032A332 + (17:22:13, 20 December 2024)
- ML20032A331 + (17:22:15, 20 December 2024)
- B10320, Criticizes NRC Release of Inaccurate Info Used in Ny Times Article Re Potential for Reactor Vessel Failure Due to Pressurized Thermal Shock.Requests That NRC Inform Util in Future of Info Released to Media for Public Disclosure + (17:22:16, 20 December 2024)
- PNO-I-81-116, on 811021,minor Earthquake of 3.5 on Richter Scale Felt Onsite.Site in Preoperational Phase & No Fuel Onsite.No Damage Occurred + (17:22:19, 20 December 2024)
- ML20032A328 + (17:22:20, 20 December 2024)
- ML20032A327 + (17:22:21, 20 December 2024)
- ML20032A326 + (17:22:22, 20 December 2024)
- ML20032A325 + (17:22:23, 20 December 2024)
- 05000296/LER-1981-050-03, /03L-0:on 810922,during Normal Operation,Generator Coupling on 3EA LPCI MG Set Became Loose.Caused by Slipping of Retainer Ring.Generator Coupling Reassembled & Lubricated + (17:22:24, 20 December 2024)
- ML20032A322 + (17:22:26, 20 December 2024)
- ML20032A321 + (17:22:27, 20 December 2024)
- ML20032A319 + (17:22:28, 20 December 2024)
- ML20032A318 + (17:22:29, 20 December 2024)
- 05000296/LER-1981-050, Forwards LER 81-050/03L-0 + (17:22:31, 20 December 2024)
- 05000369/LER-1981-159-03, /03L-0:on 810915,while in Mode 3,boron Injection Tank Discharge Isolation Valve Began Binding While Opening After Adjustment to Packing.Cause Undetermined.Packing Loosened & Valve Cycled Manually.Motor Replaced + (17:22:33, 20 December 2024)
- ML20032A314 + (17:22:34, 20 December 2024)
- ML20032A313 + (17:22:34, 20 December 2024)
- 05000369/LER-1981-159, Forwards LER 81-159/03L-0 + (17:22:36, 20 December 2024)
- 05000282/LER-1981-023-03, /03L-0:on 810921,during Surveillance Test,One Cooling Water Header Isolation Valve Did Not Close Fully. Caused by Wet Motor Leads in Junction Box.Wiring Renewed + (17:22:38, 20 December 2024)
- ML20032A307 + (17:22:40, 20 December 2024)
- PNO-I-81-117, on 811021,offgas Holdup Isolation Valve Failed Closed Requiring Power Reduction & Reactor Shutdown to Avoid Condenser Vacuum Loss.Caused by Cutting nonsafety-related Instrument Control Wiring + (17:22:41, 20 December 2024)
- 05000282/LER-1981-023, Forwards LER 81-023/03L-0 + (17:22:43, 20 December 2024)
- ML20032A303 + (17:22:44, 20 December 2024)
- 05000369/LER-1981-152-03, /03L-0:on 810831,steam Generator 1C Main Feed to Auxiliary Feedwater Nozzle Isolation Valve Would Not Operate Electrically from Control Room.Caused by Burned Out Motor & Flasher for Overload Heater.Motor Replaced + (17:22:46, 20 December 2024)
- ML20032A299 + (17:22:47, 20 December 2024)
- ML20032A298 + (17:22:48, 20 December 2024)
- ML20032A295 + (17:22:52, 20 December 2024)
- 05000369/LER-1981-152, Forwards LER 81-152/03L-0.Detailed Event Analysis Encl + (17:22:54, 20 December 2024)