Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19309E690 + (07:58:48, 2 January 2025)
- ML19309E688 + (07:58:49, 2 January 2025)
- ML19309E687 + (07:58:50, 2 January 2025)
- ML19309E686 + (07:58:51, 2 January 2025)
- ML19309E685 + (07:58:52, 2 January 2025)
- ML19309E684 + (07:58:53, 2 January 2025)
- ML19309E683 + (07:58:54, 2 January 2025)
- ML19309E682 + (07:58:55, 2 January 2025)
- ML19309E681 + (07:58:56, 2 January 2025)
- ML19309E680 + (07:58:57, 2 January 2025)
- ML19309E677 + (07:58:58, 2 January 2025)
- ML19309E676 + (07:58:59, 2 January 2025)
- ML19309E675 + (07:59:00, 2 January 2025)
- ML19309E674 + (07:59:01, 2 January 2025)
- ML19309E673 + (07:59:02, 2 January 2025)
- ML19309E672 + (07:59:03, 2 January 2025)
- ML19309E671 + (07:59:04, 2 January 2025)
- 05000333/LER-1980-027-03, /03L-0:on 800322,HPCI Was Made Inoperable to Repair Pipe Support.Caused by Need to Repair Hangar Re HPCI Sys Steam Supply.Hcpi Restored to Operable Status in Standby Mode + (07:59:05, 2 January 2025)
- 05000333/LER-1980-027, Forwards LER 80-027/03L-0 + (07:59:07, 2 January 2025)
- ML19309E666 + (07:59:12, 2 January 2025)
- ML19309E665 + (07:59:13, 2 January 2025)
- 05000318/LER-1980-021-03, /03L-0:on 800318,during Performance of Surveillance Test 23,saltwater Pump Did Not Start Upon Receipt of Safety Actuation Signal.Caused by Faulty Pin. Pin Replaced + (07:59:17, 2 January 2025)
- 05000327/LER-1980-027-03, /03L-0:on 800318,during Mode 6 operations,FCY-26- 240,241,242,243,244 & 245 Were Identified Closed.Caused by Inadequate Phase a Recovery Procedure.Valves Opened. Temporary Change Made to Procedure to Require Reopening + (07:59:19, 2 January 2025)
- ML19309E662 + (07:59:20, 2 January 2025)
- 05000327/LER-1980-027, Forwards LER 80-027/03L-0 + (07:59:21, 2 January 2025)
- ML19309E658 + (07:59:22, 2 January 2025)
- 05000259/LER-1980-027-03, /03L-0:on 800322,while Performing SI 4.2.B-14, RHRSW Pump D3 Timer Found 3-S Less than Min Requirement. Cause Unknown.Timer Adjusted & Verified within Tech Spec Tolerance + (07:59:25, 2 January 2025)
- ML19309E654 + (07:59:27, 2 January 2025)
- 05000318/LER-1980-021, Forwards LER 80-021/03L-0 + (07:59:30, 2 January 2025)
- 05000259/LER-1980-027, Forwards LER 80-027/03L-0 + (07:59:32, 2 January 2025)
- 05000324/LER-1980-031-01, /01T-0:on 800404,while Investigating Why Pressure Could Not Be Maintained During Local Leak Rate Test on RWCU Isolation Valves F001 & F004,horizontal 0.25-inch Crack Was Found in heat-affected Zone.Cause Being Examined + (07:59:34, 2 January 2025)
- 05000348/LER-1980-021-03, /03L-0:on 800316,during Review of Surveillance Test Schedule,Found FNP-1-STP-9.0,RCS Leakage Test Had Not Been Performed within Time Interval.Cause Not Stated. Personnel Instructed Re Test Interval + (07:59:35, 2 January 2025)
- 05000366/LER-1980-045-01, /01T-0:on 800404,while in Cold Shutdown,Leak Rate Test Was Performed on Auto Depressurization Sys Valves Air Supply Accumulator Check Valves.Leaks Were Beyond Acceptable Rate.Cause Unknown.Valves Will Be Repaired Prior to St + (07:59:37, 2 January 2025)
- 05000366/LER-1980-035-03, /03L-0:on 800321,during Calibr Procedure HNP-2-5329,all But Six Accumulator Pressure Switches Found to Be Outside Tech Specs.Caused by Personnel Error & Component Failure.Pressure Switches Recalibr + (07:59:40, 2 January 2025)
- 05000324/LER-1980-031, Forwards LER 80-031/01T-0 + (07:59:41, 2 January 2025)
- ML19309E637 + (07:59:43, 2 January 2025)
- ML19309E640 + (07:59:43, 2 January 2025)
- 05000348/LER-1980-021, Forwards LER 80-021/03L-0 & Updated LER 79-056/03L-1 + (07:59:45, 2 January 2025)
- 05000366/LER-1980-045, Forwards LER 80-045/01T-0 + (07:59:46, 2 January 2025)
- 05000366/LER-1980-035, Forwards LER 80-035/03L-0 + (07:59:49, 2 January 2025)
- 05000327/LER-1980-026-03, /03L-0:on 800416,during Mode 6 Operations,Ercw Effluent Line Monitors Declared Inoperable & Maint Performed.Caused by Dirt in Flow Switch.Switch Cleaned & Monitor Returned to Svc + (07:59:51, 2 January 2025)
- 05000321/LER-1980-029-03, /03L-0:on 800322,during Normal Surveillance, Generator 1R43-S001C Failed to Start & Reach Rated Speed within 12-s.Caused by Bent Shutdown Solenoid Operating Rod in Engine Governor & Failed Governor Booster Servo + (07:59:52, 2 January 2025)
- ML19309E627 + (07:59:54, 2 January 2025)
- 05000317/LER-1980-021-04, /04T-0:on 800404,during Preventive Maint for Draining Condensate from Fuel Oil Storage Tank,Operator Drained Oil Instead of Water.Caused by Operator Inability to Discern Difference Between Oil & Water Through Bullseye + (07:59:55, 2 January 2025)
- 05000366/LER-1980-043-03, /03L-0:on 800401,while in Cold Shutdown & Performing Insp Required by IE Bulletin 80-03,noticeable Amount of Carbon Found on Floor of Both Trains of Refueling Floor Ventilation Sys.Probably Caused by Improper Packing + (07:59:57, 2 January 2025)
- ML19309E623 + (07:59:58, 2 January 2025)
- 05000327/LER-1980-026, Forwards LER 80-026/03L-0 + (07:59:59, 2 January 2025)
- 05000321/LER-1980-029, Forwards LER 80-029/03L-0 + (08:00:01, 2 January 2025)
- 05000321/LER-1980-030-03, /03L-0:on 800330,w/mode Switch in Run Position & Reactor at 2,432 Mwt,Discovered Analyzer B of Primary Containment Hydrogen & Oxygen Analyzer Inoperable.Caused by Personnel Error.Problem Corrected.Analyzer Returned to Svc + (08:00:02, 2 January 2025)
- ML19309E617 + (08:00:04, 2 January 2025)
- 05000317/LER-1980-021, Forwards LER 80-021/04T-0 + (08:00:05, 2 January 2025)